Rated max. power of the emitter
(W)
Separation distance in metres (m) according to emitter frequency
150 KHz to 80 MHz
d = 1.2
P
80 MHz to 800 MHz
d = 1.2
P
800 MHz to 2,5 GHz
d = 2.3
P
0.01
0.12 m
0.12 m
0.23 m
0.1
0.38 m
0.38 m
0.73 m
1
1.2 m
1.2 m
2.3 m
10
3.8 m
3.8 m
7.3 m
100
12m
12m
23m
For emitters rated at max. power not listed above, the recommended separation distance d in meteres
(m) can be estimated using the equation applicable to the frequency of the emitter, where P is the
max. power rating of the emitter in watts (W) according the manufacturer.
Note 1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These specifications may not be applicable in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and persons.
13. 5 CABLE LENGTHS
Cables and
accessories
Maximum
length
Complies with:
Handpiece cords
Footswitch cord
Power supply cord
Less than 3m
RF emission, CISPR 1 - Class B/Group 1
Harmonic current emission: IEC61000-3-2
Voltage fluctuation: IEC61000-3-3
Immunity to electrostatic discharge: IEC61000-4-2
Immunity to electrical fast transients/bursts: IEC61000-4-4
Immunity to surges: IEC61000-4-5
Immunity to voltage dips, short interruptions and voltage
variations: IEC61000-4-11
Immunity to conducted disturbances induced by radiofrequency
fields: IEC61000-4-6
Immunity to radiated radiofrequency electromagnetic fields:
IEC61000-4-3
XIV - DISPOSAL AND RECYCLING
As electrical and electronic equipment, the device must be disposed of according to a specialized
procedure for collection, pick-up and recycling or destruction (in particular on the European market,
with reference to Directive 2002/96/EC of 27/01/2003).
When your device reaches the end of its life, we consequently recommend that you contact your dental
equipment dealer (or, failing this, the ACTEON Group website, the address of which is given in chapter
18), for information on how to proceed.
XV - -MANUFACTURER'S LIABILITY
The manufacturer is not liable if:
- the manufacturer's installation recommendations have not been followed (supply voltage,
electromagnetic environment, etc.)
- repairs or other work have been done on the device by persons not authorized by the manufacturer
Содержание Satelec Implant Center 2
Страница 1: ......
Страница 28: ...31 JJJJ Baujahr 32 Wechselstrom 33 Fußpedalkabel 34 O Gerät AUS 35 I Gerät EIN 36 Aktives UItraschallteil ...
Страница 56: ...FIG 2 FIG 3 ...
Страница 57: ...FIG 4 FIG 5 ...
Страница 58: ...FIG 6 ...
Страница 59: ...FIG 7 FIG 8 ...