Note: The options assigned to an individual user operate in addition to those assigned to the group.
Option
Description
2
Activate O/P 2
The general-purpose output OP2 is activated for its programmed
duration when this user is granted access.
3
Activate O/P 3
The general-purpose output OP3 is activated for its programmed
duration when this user is granted access.
T
Toggle Relay
When the user is granted access, the relay is toggled so the door will
remain permanently open until the next time the card or token is read.
The door must be set for Toggle Relay operation.
R Extended Relay
If this option is selected the Main Relay will fire for an Extended
Time
time when a user with this option is granted access. The Extended
relay time is set on a door by door basis. See installer menu->door
settings
A Aux Arm/Disarm
Setting this option gives the user the rights to activate/deactivate an
external Alarm. See end of the manual for more details.
ASSIGN PINS
The
Assign PINs
function allows a different PIN to be assigned to each user. Initially, the PIN will
be
unset.
Pressing the
✔
key will prompt for the PIN for the displayed user to be entered (it will
not be displayed). The PIN must then be re-entered for verification. The PIN will be accepted as
long as it does not conflict with any existing PIN (or duress PIN). Entering all zeros will delete
the PIN. The actual PIN is never shown on the display.
In
PIN Only
operation, this is the PIN that that user must enter to gain access. In this case, the
PIN must be unique. In PIN & Card operation, this is the PIN that must be entered after the user
has presented a card to the reader. If a PIN for a user is not set, then the relevant group PIN may
be used instead (PIN & Card only).
LEARN
In
Learn Mode,
all 30,000 users may be allocated a randomly coded card in place of the usual site
coded card. Any card with valid data on ISO Track 2 may be used. Certain types of wiegand cards
may also be used.
Initially the display will show
Not Assigned
for the selected user indicating that a learned card
has not been assigned. Pressing the
✔
key prompts the user to select a door to learn from. After
selecting a door, the user presents a card to the reader at that door. When the user presents the card
to the reader, a unique 10-digit number generated from the data on the card is displayed. This card
may then be used to gain access, and will replace any previously learned card.
Instead of presenting the card, the 10-digit number may be directly entered on the keyboard, if it
is known in advance.
Learning cards is particularly useful for visitors who could, for example, use their personal
bankcards to gain access for the duration of their visit.
BATCH CARDS
The Batch Cards function allows a sequential batch of cards to be assigned to a sequential range
of users (e.g. card numbers 1001 to 1200 assigned from user 1 to user 200, where user 1 has card
1001). The ACTpro 3000 supports up to 100 batches. Users may be assigned different cards in
different batches if desired.