![ACT ACTPRO 3000 ACCESS CONTROL UNITS Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/act/actpro-3000-access-control-units/actpro-3000-access-control-units_operating-and-installation-instructions_2842160017.webp)
ACTpro 3000 Operating Instructions
Firmware Version 1.24
13
Installer Menu
*
Installer will first be required to select a door.
System Settings
Operation
PIN Only
PINs alone are used to gain access.
Learn
All 30000 may use random coded cards.
Exit PINs
Exit PINs may be used in PIN only mode.
User Limiting
Prevent access if the user limit is reached.
One-To-One
Card numbers may be assigned to all users.
Multiple
Users may have multiple cards.
Display
Backlight
Keypad backlight enabled
Keypad Beep
Keypad beep enabled
Show Status
Display current status of doors on LCD
Show Events
Display events on LCD as they occur
Handshake
Use handshake line when printing
Tech Bleep
Controller bleeps for technical fault
Language
Set the controllers operational Language.
PIN Length
Sets the length of user/group PIN codes.
Fire Doors
Allows the definition of doors with fire override.
User Tracking
Perimeter
Define Perimeter doors
Antipassback
Define Antipassback doors
Timed
Define Timed Antipassback doors
antipassback
Internal Doors
Define Internal doors
Tracking Reset
Set time for auto-reset (auto-logout)
User Limits
Set user limits A & B
Outputs
Door 1
Define door 1 output special functions
Door 2
Define door 2 output special functions
Door Settings*
Operation
Push Button
Door release button enabled
Lock Saver
Relay de-energized as door opens
Chime
Buzzer sounds as door opens
Guest Button
on external keypad fires AUX/buzzer
Exit Always
Timezones don’t apply to exit readers
Interlock
Only one door may be open at any time.
Silent
Confirmation tones disabled
Exit PIR
Door stays open while Push Button closed
Failsafe
Door relay is normally energised
Toggle Relay
Door has toggle operation
Monitor Arm
AUX input monitors Intruder panel status
Alarms
Door Forced
Aux relay activated if door forced
Door Ajar
Aux relay activated if door left ajar
Duress Alarm
Aux relay activated by duress code
Door Open
Aux relay active while door open
Acc. Granted
Aux relay fires access granted
Exit Granted
Aux relay fires Exit denied
Acc. Denied
Aux relay fires when access denied.
Exit Denied
Aux relay fires when Exit denied.
Relay Follow
Aux relay active if main Relay is active.
Arm Intruder
Aux relay activates to arm Intruder panel