Suburban Dynaline 3 A&E Manual 12/2021 Rev.2
7
Copper and aluminum
evaporator and
condenser coils:
For extended life and
ease of repair. Coils
use seamless copper
tubing, mechanically
expanded into
aluminum plate fins.
Compressor lock-out:
Standard design
provides means of lock-
ing out A/C
compressor when
standby power
generator is operating.
Electronic control
board has 24V input
terminals to receive
lock-out signal.
Room air discharge:
Attractive, durable
grille constructed of
extruded aluminum,
52° off vertical air
discharge pattern.
Return air filter:
No tools are needed to
install or remove the
permanent electrostatic
filter constructed of
washable media.
END VIEW (LH)
Figure 3
40
14
9
—
32
21
14
7—
8
1—
16
7
25—
32
42
7
14
42
16
16
42
11
—
16
40
5
—
8
3—
8
14
3—
4
UNIT WALL SLEEVE DIMENSIONS
Figure 4
Specifications subject to change without notice.
Freeze Protection:
Forces heating operation in standby, cooling and fan-only
mode when the interior temperature drops below 45°F to
help protect pipes, plumbing fixtures and sprinkler systems
from freeze damage. Freeze Protection is enabled by default,
but can be disabled. If a remote wall-mount thermostat is
used, be sure to select one that is compatible with this
feature.
Carbon Monoxide Detector
An integrated carbon monoxide (CO) detector is standard on
all Dynaline 3 models. It has been verified to perform in the
detection of carbon monoxide up to 12,000 ft above sea level
and will alarm within the time specified by ANSI/UL 2034 for
carbon monoxide concentrations of 70, 150 and 400 parts per
million (ppm).
NEW STANDARD FEATURES