AET62 Reference Manual
Version 1.0
Page 33 of 37
idvation GmbH
Otto-Hesse-Straße 19 / T5
Phone +49 6151 4923021
D-64293 Darmstadt
Fax +49 6151 3689296
www.idvation.com
11. Appendix C. APDU Command and Response Flow for ISO 18092-Compliant
Tags
Assume a TOPAZ tag is used.
<< Typical APDU Command and Response Flow >>
PC
Reader
Tag
Sequences
USB Interface
(12Mbps)
RF Interface
(13.56MHz)
1. The command
is sent
Contactless Related
Command
Tag-specific Command Frame
[Native Command]
e.g. [01 08] (read
memory address 08)
Pseudo APDU
Command
+
[Native Command]
e.g.
FF 00 00 00 05
D4 40 01
[01 08]
[Native Command]
embedded in
ISO18092 Frame
2. The response
is received
Contactless Related
Response
Tag-specific Response Frame
[Native Response]
e.g. 00 (90 00)
or
Pseudo APDU
Response
+ [Native Response]
e.g.
D5 41 00
[00]
(90 00)
e.g.
[Native Response]
embedded in
ISO18092 Frame