5. PICC Commands for General Purposes
5.1.
Get Data
The “Get Data command” will return the serial number or ATS of the “connected PICC”.
Version 1.00
Command
Class
INS
P1
P2
Le
Get Data FF
CA
00 01
00
00
(Full
Length)
Table 4: Get UID APDU Format (5 Bytes)
Response Data Out
Result
UID
(LSB)
UID
(MSB)
SW1
SW2
Table 5: Get UID Response Format (UID + 2 Bytes) if P1 = 0x00
Response
Data Out
Result
ATS
SW1
SW2
Table 6: Get ATS of a ISO 14443 A card (ATS + 2 Bytes) if P1 = 0x01
Results
SW1
SW2
Meaning
Success 90
00
The operation is completed
successfully.
Error
63
00
The operation is failed.
Error
6A
81
Function not supported.
Table 7: Response Codes
Example:
1.
To get the serial number of the “connected PICC”
UINT8
GET_UID
[5]={
0xFF, 0xCA, 0x00, 0x00, 0x04
};
2.
To get the ATS of the “connected ISO 14443 A PICC”
UINT8
GET_ATS
[5]={
0xFF, 0xCA, 0x01, 0x00, 0x04
};