AET62 Reference Manual
Version 1.0
Page 21 of 37
idvation GmbH
Otto-Hesse-Straße 19 / T5
Phone +49 6151 4923021
D-64293 Darmstadt
Fax +49 6151 3689296
www.idvation.com
7.5.
Set the PICC Operating Parameter
This is used to set the PICC Operating Parameter of the reader.
Command Class
INS
P1
P2
Le
Get
Response
0xFF
0x00
0x51
New PICC
Operating
Parameter
0x00
Table 41: Command Format (5 Bytes)
Response
Data Out
Result
PICC Operating Parameter
Table 42: Response Format (1 byte)
Bit
Parameter
Description
Option
7
Auto PICC Polling
To enable the PICC Polling
1 = Enable
0 = Disable
6
Auto ATS Generation
To issue ATS Request
whenever an ISO14443-4
Type A tag is activated
1 = Enable
0 = Disable
5
Polling Interval
To set the time interval
between successive PICC
Polling.
1 = 250 ms
0 = 500 ms
4
FeliCa 424K
The Tag Types to be
detected during PICC
Polling.
1 = Detect
0 = Skip
3
FeliCa 212K
1 = Detect
0 = Skip
2
Topaz
1 = Detect
0 = Skip
1
ISO14443 Type B
1 = Detect
0 = Skip
0
ISO14443 Type A
#To detect the Mifare
Tags, the Auto ATS
Generation must be
disabled first.
1 = Detect
0 = Skip
Table 43: PICC Operating Parameter. Default Value = FF