3. Terminal installation
3.1 Electrical connections
Wiring connections for power, PC
interface or printer (stand-alone
mode) and mounting bracket can be
located by removing the terminal's
access door.
3.2 Terminal mounting
The Time Clock terminal is supplied with a reversible bracket on back
of the unit for desk or wall mounting. The unit is shipped with the
bracket in the desk mounting position. With the access door removed,
you are able to remove the bracket. Reverse the bracket and secure the
bracket to the wall with the four screws. Recommended distance from
floor to top of bracket is 54". The bracket has molded wire routing slots
and a center hub for securing wires using nylon ties. After the bracket is
fastened to the wall, mount the terminal on to the bracket. Complete
wiring connections and replace the access door.
3.3 Connecting Time Clock terminal to IBM compatible PC
1. Make sure power is off at both
the Time Clock terminal and
the PC, and the access door
on the terminal is removed.
2. Using the cable supplied with
the terminal (50'), connect the
RJ-11 modular connector to
the RS-232 port on the lower
left corner.
3. Connect the other end of the
RJ-11 to the 9-pin adaptor
Access Door
W
W
AND
AND
RS
RS
485
485
RS
RS
232
232
9V
9V
Terminal installation