Acromag PMC408 Series Скачать руководство пользователя страница 11

SERIES PMC408 PCI MEZZANINE CARD                                                  32-CHANNEL DIGITAL I/O MODULE 
___________________________________________________________________________________________

 

- 10 - 

termination allows the PCI bus to be free for other system  
operations while the data is moved to the read register.  

 
A PCI bus write to the PMC module will result in 1) 

immmediately accepting the write data and normal cycle termination 
or 2) issue of a retry termination.  A retry termination will be issued if 
the previous write cycle has not completed on the PMC module.  It 
will typically take the PMC module 1000ns to write the data to the 
required internal register.  Thus if another write cycle is initiated on 
the PCI bus before the typical 1000ns has lapsed, the write cycle will 
be terminated with a retry.   

 
A programmable logic device provides the control signals 

required to operate the board.  It decodes the selected addresses, 
control signals, and interrupt handling.  It also returns the 
acknowledgement signal required by the carrier/CPU board per the 
PMC specification.  The program for the gate array is stored in 
separate PROM memory and loaded upon power-up. 

 

 
PMC Module Software 

 
Acromag also provides a software product (sold separately) 

consisting of PMC module ActiveX (Object Linking and Embedding) 
controls for Windows 98, 95

®

, ME, 2000 and Windows NT

®

 

compatible application programs (Model PMCSW- ATX, MSDOS 
format).  This software provides individual controls that allow 
Acromag PMC modules to be easily integrated into Windows

®

 

application programs, such as Visual C++

, Visual Basic

®

Microsoft

®

 Office

®

 97 applications and others.  The ActiveX 

controls provide a high-level interface to PMC modules, eliminating 
the need to perform low-level reads/writes of registers, and the 
writing of interrupt handlers—all the complicated details of 
programming are handled by the ActiveX controls.  These functions 
consist of ActiveX control for each Acromag PMC module. 

 
In addition, Acromag provides a software product (sold 

separately) consisting of PMC module VxWorks

®

 libraries.  This 

software (Model PMCSW-API-VXW, MSDOS format) is composed 
of VxWorks

®

 (real time operating system) libraries for all Acromag 

PMC modules.  The software is implemented as a library of “C” 
functions which link with existing user code to make possible simple 
control of all Acromag PMC modules. 

 
5.0 SERVICE AND REPAIR 

 

SERVICE AND REPAIR ASSISTANCE 

 

Surface-Mounted Technology (SMT) boards are generally 

difficult to repair.  It is highly recommended that a non-functioning 
board be returned to Acromag for repair.  The board can be easily 
damaged unless special SMT repair and service tools are used.  
Further, Acromag has automated test equipment that thoroughly 
checks the performance of each board.  When a board is first 
produced and when any repair is made, it is tested, placed in a burn-
in room at elevated temperature, and retested before shipment. 
Please refer to Acromag's Service Policy Bulletin or contact 
Acromag for complete details on how to obtain parts and repair. 
 

PRELIMINARY SERVICE PROCEDURE 

 

Before beginning repair, be sure that all of the procedures in 

Section 2, Preparation For Use, have been followed.  Also, refer to 
the documentation of your carrier board to verify that it is correctly 

configured.  Replacement of the module with one that is known to 
work correctly is a good technique to isolate a faulty module. 

 

CAUTION:

  POWER MUST BE TURNED OFF BEFORE 

                    REMOVING OR INSERTING BOARDS 

 

Acromag’s Applications Engineers can provide further technical 

assistance if required.  When needed, complete repair services are 
also available from Acromag. 

 

6.0  SPECIFICATIONS 
 

 
PHYSICAL 

Physical Configuration……....  Single PMC Module. 

Height.............................… 15.11 mm (0.595 in). 

(See Drawing 4501-859) 

Stacking Height………….. 10.0 mm (0.394 in). 
Length.............................…149.0 mm (5.866 in). 
Width............................….. 74.0 mm (2.913 in). 
Board Thickness...........…..1.59 mm (0.062 in). 
 

 

Connectors:  

PCI Local Bus Interface..... Two 64-pin female receptacle header 

(AMP 120527-1 or equivalent). 

Field I/O…….................…. 50-pin, SCSI-2, female receptacle 

header (AMP 787082-5 or 
equivalent). 

 

Power Requirements

 

PMC408(E)

 

5V

1

 Typical 

65 

mA 

(

±

5%) Max. 

90 

mA 

+12V Typical 

mA 

(

±

5%) Max. 

12 

mA 

-12V Typical 

Not 

Used 

(

±

5%) Max. 

 

1. 

Maximum rise time of 100 milliseconds 

 

ENVIRONMENTAL 

 

Operating Temperature.......…… 0 to +70

°

C. 

-40 to +85

°

C (E Versions) 

Relative Humidity….....................5-95% Non-Condensing. 
Storage Temperature.…............. -55 to 105

°

C. 

Non-Isolated....................…...…. Logic and field commons have a 

direct electrical connection. 

Radiated Field Immunity (RFI)..  Designed to comply with IEC1000-

4-3 Level 3 (10V/m, 80 to 
1000MHz AM & 900MHz. Keyed) 
and European Norm EN50082-1 
with no data upsets. 

Electromagnetic Interference  
Immunity (EMI)…...…..……...... 

 
No data upsets occur under the 
influence of EMI from switching 
solenoids, commutator motors, 
and drill motors. 

Surge Immunity……………….… Not required for signal I/O per 

European Norm EN50082-1. 

ESD Protection……..........….... 
 
 

Complies with IEC1000-2 Level 1 
(2KV direct contact discharge at 
input/output terminals) and 
European Standard 
EN50082-1. 

Содержание PMC408 Series

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...dule USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 2000 Acromag Inc Printed in the USA Data and specificat...

Страница 3: ...PLE INPUT CONNECTIONS 16 4501 758 CABLE SCSI 2 to Flat Ribbon Shielded 5028 187 17 4501 464 TERMINATION PANEL 5025 552 18 IMPORTANT SAFETY CONSIDERATIONS It is very important for the user to consider...

Страница 4: ...5 187 SCSI 2 to Flat Ribbon Cable Shielded A round 50 conductor shielded cable with a male SCSI 2 connector at one end and a flat female ribbon connector at the other end The cable is used for connect...

Страница 5: ...e connection The PMC408 is non isolated between the logic and field I O grounds since output common is electrically connected to the PMC module ground Consequently the field I O connections are not is...

Страница 6: ...provides the specific information necessary to program and operate the PMC408 module This Acromag PMC408 is a PCI Local Bus Specification version 2 2 compliant PCI bus target only PMC module The carri...

Страница 7: ...t Channel Register B CH31 CH24 READ Digital Input Channel Register B CH23 CH16 204 209 R W Digital Output Channel Register A CH15 CH08 R W Digital Output Channel Register A CH07 CH00 208 20D R W Digit...

Страница 8: ...ical control applications it is recommended that outputs be directly fed back to input points and the input points monitored loopback I O By design input channels are tied to the drains of the tandem...

Страница 9: ...h at selected input channels Interrupts generated by the PMC408 use interrupt request line INTA The interrupt release mechanism employed is the Release On Register Access RORA type This means that the...

Страница 10: ...it a 0 will turn it OFF open circuit Since the input buffers are connected in tandem with the output mosfets efficient loopback monitoring of the output state can be accomplished by reading the input...

Страница 11: ...AIR SERVICE AND REPAIR ASSISTANCE Surface Mounted Technology SMT boards are generally difficult to repair It is highly recommended that a non functioning board be returned to Acromag for repair The bo...

Страница 12: ...cted in tandem to the same I O pin Output ON Current Range 0 to 1A DC continuous up to 10A total for all channels combined or 300mA DC continuous all channels ON No deration required at elevated ambie...

Страница 13: ...izing key to prevent improper installation Schematic and Physical Attributes See Drawing 4501 758 Electrical Specifications 30 VAC per UL and CSA SCSI 2 connector spec s 1 Amp maximum at 50 energized...

Страница 14: ...SERIES PMC408 PCI MEZZANINE CARD 32 CHANNEL DIGITAL I O MODULE ___________________________________________________________________________________________ 13...

Страница 15: ...SERIES PMC408 PCI MEZZANINE CARD 32 CHANNEL DIGITAL I O MODULE ___________________________________________________________________________________________ 14...

Страница 16: ...SERIES PMC408 PCI MEZZANINE CARD 32 CHANNEL DIGITAL I O MODULE ___________________________________________________________________________________________ 15...

Страница 17: ...SERIES PMC408 PCI MEZZANINE CARD 32 CHANNEL DIGITAL I O MODULE ___________________________________________________________________________________________ 16...

Страница 18: ...SERIES PMC408 PCI MEZZANINE CARD 32 CHANNEL DIGITAL I O MODULE ___________________________________________________________________________________________ 17...

Страница 19: ...SERIES PMC408 PCI MEZZANINE CARD 32 CHANNEL DIGITAL I O MODULE ___________________________________________________________________________________________ 18...

Страница 20: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: