5.0  SERVICE AND REPAIR 

 

CAUTION:

  Risk of Electric Shock - More than one 

disconnect switch may be required to de-energize the 
equipment before servicing. 

 

SERVICE AND REPAIR ASSISTANCE 

 

This module contains solid-state components and requires no 

maintenance, except for periodic cleaning and transmitter 
configuration parameter (zero, full-scale, setpoint, deadband, etc) 
verification.  Since Surface Mounted Technology (SMT) boards 
are generally difficult to repair, it is highly recommended that a 
non-functioning module be returned to Acromag for repair.  The 
board can be damaged unless special SMT repair and service 
tools are used.  Further, Acromag has automated test equipment 
that thoroughly checks and calibrates the performance of each 
module.  Please refer to Acromag’s Service Policy Bulletin or 
contact Acromag for complete details on how to obtain service 
parts and repair. 
 

PRELIMINARY SERVICE PROCEDURE 

 
Before beginning repair, be sure that all installation and 

configuration procedures have been followed.  The unit routinely 
performs internal diagnostics following power-up or reset.  During 
this period, all LED’s will turn ON momentarily, and the green 
“Run” LED flashes.  If the diagnostics complete successfully, the 
“Run” LED will stop flashing after approximately one second and 
remain ON.  This indicates that the unit is operating normally.  If 
the “Run” LED continues to flash, then this is indicative of a 
problem.  In this case, use the Acromag IntelliPack Configuration 
Software to reconfigure the module or download its firmware and 
this will usually cure the problem.  If the diagnostics continue to 
indicate a problem (a continuously flashing green LED), or if other 
evidence points to a problem with the unit, an effective and 
convenient fault diagnosis method is to exchange the 
questionable module with a known good unit. 

 
The IntelliPack Serial Port Adapter also contains a red LED 

visible at the small opening in the enclosure to the right of the 
RJ11 receptacle.  If this LED is OFF or Flashing and power is 
ON, then a communication interface problem exists.  Note that 
the adapter receives its power from the IntelliPack module.  A 
constant ON LED indicates a properly working and powered 
serial interface adapter. 

 
Acromag’s Application Engineers can provide further 

technical assistance if required.  When needed, complete repair 
services are available from Acromag. 
 
 

6.0  SPECIFICATIONS 

 

892M-0500-C

, Two I/V Inputs, Single Process I/V Output 

894M-0500-C

, Four I/V Inputs, Single Process I/V Output 

 

General:

  The IntelliPack Model 89XM-0500 is a DC-powered 

computation transmitter which mathematically combines up 
to four channels of process current or voltage, and provides 
an isolated current or voltage output that is the result of a 
programmed equation that operates on the inputs.  Isolation 
is supplied between the input, output, and power. 

 
Input channels share common and are not isolated from each 
other.  This transmitter is DIN-rail mounted.   

 

The unit is configured and calibrated with our user-friendly 
Window 95/98

 or NT

 IntelliPack Configuration Program.  

All calibration and configuration information is stored in non-
volatile reprogrammable memory in the module. 

 

MODEL NUMBER DEFINITION 
 

Transmitters are color coded with a white label.  The prefix “8” 
denotes the IntelliPack Series 800, while the “M” suffix specifies 
that this device is primarily a computation (Math) transmitter. 

 
89xM:

  Provides a resultant isolated DC current or voltage output 

response to a mathematical equation that combines up to 
two or four DC voltage or current inputs. 

 
-0500:

  The four digits of this model suffix represent the following 

options, respectively: 

 

0 = Relay: No Alarm Relay; 
5 = Output: Transmitter Voltage or Current; 
0 = Enclosure: DIN rail mount; 
0 = Approvals: cULus Listed. 
 

INPUT SPECIFICATIONS 

 

Unit must be wired and configured for the intended input types 
and ranges (see Installation Section for details).  The following 
paragraphs summarize this model’s input types, ranges, and 
applicable specifications. 
 

DC (Process) Current:

  0-1mA, 0-20mA, and 4-20mA.  All input 

ranges are subsets of the 0-20mA input range.  A precision 
49.9

 current sink resistor is placed in the I+ input lead and 

converts the input current to a voltage that is processed by 
the A/D converter.  Input I+ must be jumpered to the V+ 
terminal to utilize current input.  This module also provides an 
excitation supply (15VDC/48mA) for use with 2-wire 
transmitters. 

Current Input Reference Test Conditions:

  4 to 20mA input 

(jumper installed); Ambient Temperature = 25

C; Power 

Supply = 24VDC; Output = 4-20mA, Normal Acting; Output 
Formula = average of combined inputs [(A + B + C + D)/4]. 

Input Overvoltage Protection:

  Bipolar Transient Voltage 

Suppressers (TVS), 18V clamp level typical. 

Input Resistance:

  550K

, typical. 

 
DC Voltage (10:1 Input Divider):

 0-5VDC or 0-10VDC. 

Voltage Input Reference Test Conditions:

  0 to 10V DC 

input; Ambient Temperature = 25

C; Power Supply = 24V 

DC; Output = 4-20mA, Normal Acting; Output Formula = 
average of all inputs [(A + B + C + D)/4]. 

Input Overvoltage Protection:

  Bipolar Transient Voltage 

Suppressers (TVS), 18V clamp level typical. 

 

Содержание IntelliPack 895M Series

Страница 1: ...cess Current Voltage Inputs USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0880 Fax 248 624 9234 Copyright 1998 Acromag Inc Printed in the USA Data and...

Страница 2: ...NT are registered trademarks of Microsoft Corporation 1 0 INTRODUCTION These instructions cover hardware functionality of the transmitter models listed in Table 1 Supplementary sheets are attached fo...

Страница 3: ...ash memory and EEPROM This allows the functionality of this device to be reliably reprogrammed thousands of times Fully Isolated Input output and power are isolated from each other for safety and incr...

Страница 4: ...ically protected with an anti static bag during shipment However it is recommended that the module be visually inspected for evidence of mishandling prior to applying power This circuit utilizes stati...

Страница 5: ...trical Code for installations within Canada and in accordance with the authority having jurisdiction This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locati...

Страница 6: ...solution must also be scaled to the nominal zero and full scale endpoints of the selected output range Up to 200 characters may be entered into the equation field to define a formula that relates the...

Страница 7: ...A B A D THEN A ELSE C 12 56 When formulating an equation or response it is important to keep the limits of module resolution in mind see Table 5 In some cases it may be necessary to normalize your va...

Страница 8: ...ir services are available from Acromag 6 0 SPECIFICATIONS 892M 0500 C Two I V Inputs Single Process I V Output 894M 0500 C Four I V Inputs Single Process I V Output General The IntelliPack Model 89XM...

Страница 9: ...LSB 8 4 20mA DC 16797 953nA LSB 2 0 5V DC 26298 190uV LSB 1 0 10V DC 26298 380uV LSB IMPORTANT Input COM and RTN are not the same potential and should never be connected together either directly or th...

Страница 10: ...t exceed 36VDC peak to avoid damage to the module Table 8 89XM Supply Current Supply Voltage Supply Current SPA Connected Supply Current SPA Not Connected 10V 330mA 300mA 12V 250mA 230mA 15V 200mA 175...

Страница 11: ...al EXP natural logarithm LN logarithm base 10 LOG10 power POWER sine SIN cosine COS tangent TAN arc sine ASIN arc cosine ACOS and arc tangent ATAN Support for IF THEN ELSE plus AND OR constructs are i...

Страница 12: ...N I3 2 2 2 3 2 6 2 5 2 4 I4 V4 RTN INSTAL L V TO I JUMPER AT INPUT FOR CURRENT INPUTS TRANSIENT VOL TAGE AND NOISE SUPPRESSION DEVICES ARE NOT SHOWN 4 9 9 4 9 9 K 5 4 9 K 1 6 VOL TS 4 9 9 5 4 9 K SERI...

Страница 13: ...LO Y LO Y H I Y X XL YH YL XH XL YL X LO X H I ANALOG INPUT X In pu t Sen s o r Ty p es Vol tag e DC M i l l i am p ere s DC AC Curren t wi th AC Se ns or I nput 1 2 Cal Val u e Cal HI Cal LO Val u e...

Страница 14: ...ONFIGURATION RUNNING WINDOWS 95 OR NT S E E USE R S MA NUA L MODULE CONFIGURA TION CONFIGURA TION P ORT FOR POWER RUN PWR LE D GREE N OV ERRA NGE LE D s YE LLOW 10 TO 36VD C TB4 A cromag R U N I N P U...

Страница 15: ...H HOLD DEASSERTED HI G H OR OPEN THE OUTPUT W I L L TRACK I N PUT CHANGES HOLD I S ASSERTED LOW AND W I L L HOLD THE TRANSM I T TER OUTPUT AT THE LAST VALUE SHI EL DED CABL E TB1 CURRENT J UM PER V2...

Страница 16: ...____________________________________ 16 Acromag R U N 1 2 3 4 INPU T STATU S 118 9 4 68 95 3 3 75 R 2 34 59 4 DIN EN 5 0 0 2 2 3 5 mm T RAIL DIN MO UNTING C L SCREWDRIVER SL O T FO R REMO VAL FRO M T...

Страница 17: ...________________________________________________ 17 Revision History The following table details the revision history for this document Release Date Version EGR DOC Description of Revision 03 AUG 2017...

Отзывы: