background image

       INDUSTRIAL I/O PACK SERIES AVME9675                                                         VME64x 6U CARRIER BOARD

___________________________________________________________________________________________

- 10 -

Table 3.3A:  AVME9675 6U Carrier Bd Short I/O Memory Map
Base
A
(Hex)

EVEN Byte

D15               D08

ODD Byte

D07               D00

Base
A
(Hex)

0000

↓↓↓↓

007E

IP A

I/O Space

High Byte

IP A

I/O Space

Low Byte

0001

↓↓↓↓

007F

0080

↓↓↓↓

00BE

Not Used

IP A

ID Space

Low Byte

0081

↓↓↓↓

00BF

00C0

↓↓↓↓

00FE

Not Used

Carrier Board

Registers

(See Table 3.3B)

00C1

↓↓↓↓

00FF

0100

↓↓↓↓

017E

IP B

I/O Space

High Byte

IP B

I/O Space

Low Byte

0101

↓↓↓↓

017F

0180

↓↓↓↓

01BE

Not Used

IP B

ID Space

Low Byte

0181

↓↓↓↓

01BF

01C0

↓↓↓↓

01FE

Not Used

Not Used

01C1

↓↓↓↓

01FF

0200

↓↓↓↓

027E

IP C

I/O Space

High Byte

IP C

I/O Space

Low Byte

0201

↓↓↓↓

027F

0280

↓↓↓↓

02BE

Not Used

IP C

ID Space

Low Byte

0281

↓↓↓↓

02BF

02C0

↓↓↓↓

02FE

Not Used

Not Used

02C1

↓↓↓↓

02FF

0300

↓↓↓↓

037E

IP D

I/O Space

High Byte

IP D

I/O Space

Low Byte

0301

↓↓↓↓

037F

0380

↓↓↓↓

03BE

Not Used

IP D

ID Space

Low Byte

0381

↓↓↓↓

03BF

03C0

↓↓↓↓

03FE

Not Used

Not Used

03C1

↓↓↓↓

03FF

The Input/Output (IO) and Identification (ID) spaces of each IP

are accessible via the VME64x bus Short I/O space as shown in
Table 3.3A.  The carrier board may optionally occupy memory in the
VME64x bus standard (A24) address space, if needed for IP
modules containing Memory space.  IP memory will only be mapped
into the standard memory space if it is enabled for a particular IP per
the user programmable IP Memory Enable Register (see Table 3.3B
and subsequent description).  The starting memory address for each
enabled IP and the memory size for each enabled IP module is user-
programmable via its associated IP Memory Base Address & Size
Register (see Table 3.3B and subsequent description).

Table 3.3B:  AVME9675 Carrier Board Registers
Base
A
(Hex)

EVEN Byte

D15               D08

ODD Byte

D07               D00

Base
A
(Hex)

00C0

Not Used

Carrier Board

Status Register

00C1

00C2

Not Used

Interrupt Level

Register

00C3

00C4

Not Used

IP Error

Register

00C5

00C6

Not Used

IP Memory

Enable Register

00C7

00C8

↓↓↓↓

00CE

Not Used

Not Used

00C9

↓↓↓↓

00CF

00D0

Not Used

IP_A Memory

Base Address &

Size Register

00D1

00D2

Not Used

IP_B Memory

Base Address &

Size Register

00D3

00D4

Not Used

IP_C Memory

Base Address &

Size Register

00D5

00D6

Not Used

IP_D Memory

Base Address &

Size Register

00D7

00D8

↓↓↓↓

00DE

Not Used

Not Used

00D9

↓↓↓↓

00DF

00E0

Not Used

IP Interrupt

Enable Register

00E1

00E2

Not Used

IP Interrupt

Pending Register

00E3

00E4

Not Used

IP Interrupt

Clear Register

00E5

00E6

↓↓↓↓

00FE

Not Used

Not Used

00E7

↓↓↓↓

00FF

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание AMVE9675-4E

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...D 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 2000 Acromag Inc Printed in the USA Data and specifications are subject to change without not...

Страница 3: ...Access LEDs and Pulse Stretcher Circuitry 16 Power Supply Filters 16 Power Supply Fuses 16 5 0 SERVICE AND REPAIR 16 SERVICE AND REPAIR ASSISTANCE 16 PRELIMINARY SERVICE PROCEDURE 16 6 0 SPECIFICATIO...

Страница 4: ...leverage to install and remove the board VME64x bus INTERFACE FEATURES Slave Module CR CSR Registers A24 D16 D08 O Carrier Register Short I O Access A16 D16 D08 O IP Module ID Space A16 D16 D08 O IP...

Страница 5: ...ove the maximum operating temperature The dense packing of the IP modules to the carrier board restricts air flow within the card cage and is cause for concern Adequate air circulation must be provide...

Страница 6: ...onfiguration is required All interrupt enabling status and VME64x bus interrupt level selections are configured via programmable registers on the carrier board see Section 3 for programming details Th...

Страница 7: ...3 3V 19 RsvBus GND AM3 A19 RsvBus 20 GND IACK GND A18 3 3V 21 RsvBus IACKIN SERA A17 RsvBus 22 GND IACKOUT SERB A16 3 3V 23 RsvBus AM4 GND A15 RsvBus 24 GND A07 IRQ7 A14 3 3V 25 RsvBus A06 IRQ6 A13 R...

Страница 8: ...uires that the bus master drive the system reset for the first 200mS after power up thus inhibiting any data transfers from taking place IP control registers are also reset following a power up sequen...

Страница 9: ...r 0x000000 0x00 00 00 8 bytes 0x5F to 0x7B RESERVED 0x00 00 1 byte 0x7F Program ID code 0x00 24 bytes 0x83 to 0xDF Unimplemented 0x00 00 CR Offset Address MSB LSB Content Description ROM Data MSB LSB...

Страница 10: ...onds to the geographic address of slot 3 per section 3 2 11 of the VME64x standard The AVME9675 will parity check the geographical address If bad parity is detected the local address will be set to de...

Страница 11: ...dard A24 address space if needed for IP modules containing Memory space IP memory will only be mapped into the standard memory space if it is enabled for a particular IP per the user programmable IP M...

Страница 12: ...ill not be latched or registered on the carrier An interrupt will only remain set as pending on the carrier if its corresponding IP module has an active interrupt request Bit 6 Auto Acknowledge Disabl...

Страница 13: ...space for IP D A zero disables memory space accesses Reset Condition Set to 0 memory space accesses disabled for IP D Bit 2 IP C Memory Enable Read Write Writing a 1 to this bit enables the memory sp...

Страница 14: ...system software to define a base address for the AVME9675 carrier and IP module registers Once the carrier board is mapped to the desired base address communication with its registers and the I O and...

Страница 15: ...Master to control and communicate with electronic devices that are external to the VME64x bus card cage The external electronic hardware may linked to the carrier board rear access via a transition m...

Страница 16: ...rt address space Access up to 8Mbytes of IP data mapped to Memory Space via D16 or D08 EO transfers using VME64x bus A24 standard address space Respond to two IP module interrupt requests per IP with...

Страница 17: ...ds typical Power Supply Filters Power line filters are dedicated to each IP module for filtering of the 5 12 and 12 volt supplies The power line filters are a T type filter circuit comprising ferrite...

Страница 18: ...0nS Typical all carrier board registers measured from the falling edge of DSx to the falling edge of DTACK 450nS Typical IP registers with no wait states See IP specifications for information on wait...

Страница 19: ...e logic and field side the field I O connections are not isolated from the VME64x bus Radiated Field Immunity RFI Designed to comply with IEC1000 4 3 Level 3 10V m at frequencies 27MHz to 500MHz and E...

Страница 20: ...64 Field Wiring 50 position terminal blocks with screw clamps Wire range 12 to 26 AWG Connections to TRANS 200 Transition Module P1 50 pin male header with strain relief ejectors Use Acromag 5028 187...

Страница 21: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 20 4501 800A Artisan Technology Group Quality Instrumentation Guaranteed 888...

Страница 22: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 21 4501 801A Artisan Technology Group Quality Instrumentation Guaranteed 888...

Страница 23: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 22 4501 802A Artisan Technology Group Quality Instrumentation Guaranteed 888...

Страница 24: ...IES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 23 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 S...

Страница 25: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 24 4501 464A Artisan Technology Group Quality Instrumentation Guaranteed 888...

Страница 26: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 25 4501 760B Artisan Technology Group Quality Instrumentation Guaranteed 888...

Страница 27: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: