AP500/AP520/AP521 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 41 - http://www.acromag.com
- 41 -
www.acromag.com
5.0 SPECIFICATIONS
5.1 Physical
Height
(carrier to top of module components)
: 12.5 mm (0.4921 in) [MAX]
Board Thickness:
1.0 mm (0.03937 in)
Length x Width:
70.0 mm x 30.0 mm (2.76 in x 1.18 in)
Unit Weight
(not including shipping material)
: 8g (0.282 oz)
5.2 Power Requirements
5.3 Environmental Considerations
5.3.1 Operating Temperature
All modules have an operational temperature range of -40°C to 85°C
1,2
.
Note 1: An air cooled application with an AcroPack module will require a
minimum airflow of 200LFM.
Note 2: A conduction cooled application with an AcroPack module will
require purchase of the Heatsink AP-CC-01.
Table 5.1 Model ID
Summarized below are the expected current draws for each of the specified
power supply voltages.
Power Supply
Voltage
Current Draw (Idle/Typical)
1
AP500
AP520
AP521
3.3 VDC ± 5%
60/100mA
70/110mA
70/150mA
5.0 VDC ± 5%
NOT USED
NOT USED
40/40mA
1.5 VDC ± 5%
NOT USED
12 VDC ± 5%
NOT USED
-12 VDC ± 5%
NOT USED
Note 1
:
Idle current draw was measured with no external loopbacks installed and
no active communication on any port.
Typical current draw was measured with external loopbacks installed on
every module port, actively running a loopback test using Passmark Burn-
In Test.
Summarized below are the operating temperature range, airflow and other
environmental requirements and applicable standards for the AcroPack
module.