- 21 -
ADL400 can achieve the history energy statistic in last 48 months and last 90days. (Each
tariff rate of energy can be recorded.)The history energy record can only be read by assemblage
and the length of whole part is 120 byte (60 registers), and list below is the registers’ name:
Table 10 History energy communicate address
Address
Name
Data list
Name
6000H
Assemblage of last 1 month
demand and energy
6000H
Frozen time:YY-MM
6022H
Assemblage of last 2 months
demand and energy
6001H
Frozen time: DD-hh
…
…
6002H
total active energy
6BD2H
Assemblage of last 48
months demand and energy
6004H
Spike active energy
reserve
reserve
6006H
peak active energy
7000H
Assemblage of last 1 day
demand and energy
6008H
flat active energy
7022H
Assemblage of last 2days
demand and energy
600AH
valley active energy
…
…
600CH
total reactive energy
763EH
Assemblage of last 90days
demand and energy
600EH
Spike reactive energy
6010H
peak reactive energy
6012H
flat reactive energy
6014H
valley reactive energy
6016H
Total amount of phase A
forward active energy
6018H
Total amount of phase B
forward active energy
601AH
Total amount of phase C
forward active energy
601CH
Maximum active demand
601DH
Occurrence time: mm-hh
601EH
Occurrence time :
DD-MM
601FH
Maximum reactive
demand
6020H
Occurrence time: mm-hh
6021H
Occurrence time:
DD-MM
9.4 Sub harmonic data
ADL400 has function of harmonic. The function include 31
st
harmonic statistics of voltage
and current, harmonic voltage and current of each phase apparently, harmonic active/reactive
power of each phase apparently, fundamental voltage and current of each phase apparently and