User's Manual | ACOM 2S1 | Automatic XCVR Commutator
June 2022
S e c t i o n INSTALLATION | Page 15 of 32
a)
INPUT A
connector
Connect a coaxial cable with a PL-259 plug from commutator
INPUT A
connector to the antenna connector
of transceiver A (see
Figure 2-1 | Rear panel - Connections
, Pos. (a)).
b)
INPUT B
connector
Connect a coaxial cable with a PL-259 plug from commutator
INPUT B
connector to the antenna connector
of transceiver B (see
Figure 2-1 | Rear panel - Connections
, Pos. (b)).
c)
OUTPUT
connector
Connect a coaxial cable with a PL-259 plug from the commutator
OUTPUT
connector to the common load
(amplifier's input, or antenna switch, or to the antenna directly, whichever is used). Please, see
, Pos. (c)).
d)
CONTROL A
and
CONTROL B
connectors
•
If you use YAESU FT-990 and/or FT-1000MP transceivers, please, follow instruction below.
NOTICE
Delivered control cables are directly suited for BAND DATA connectors of YAESU FT-990
and FT-1000MP transceivers.
Using an inappropriate cable may cause a serious damage to the ACOM 2S1 and your
transceivers (not covered under warranty)!
Figure 2-2 | Control cables
YAESU FT-990 and FT-1000MP transceivers
Figure 2-2 | Control cables for YAESU FT-990 and FT-1000MP transceivers
NOTICE
Be extremely careful not to mix
A
and
B
control and RF cable pairs. Damage to the
commutator and/or other equipment is possible, not covered by the warranty.