![ACKERMANN 16-2040N Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/ackermann/16-2040n/16-2040n_user-manual_458090017.webp)
USER MANUAL 16-2040N / 16-2041N / 16-2042N
Rev. 07/2016
8.2 SERVICING / MAINTANCE
• If a problem persits, and it is necessary to send the insufflator back to us, please ensure it is returned in its
original packaging to us. Please also include a detailed explanation about the malfunction.
• Upon receipt of your equipment, please inspect its condition. If there are any reservations or concerns about
the condition on delivery, we recommend you address these concerns immediately. A window of 48 hours is
allowed for these concerns to be raised. If the delivered equipment suffers any damages while in transit,
please notify us and the courier immediately. In case charges need to be implemented, we would require all
relevant information to establish liability, before we can proceed.
• Immediately check functionality of the delivered equipment.
• All repairs on the equipment will be performed by us and we reserve the right to withhold any technical
data.
9. SYMBOLS USED
DESCRIPTON
CORRESPONDING
Class 1 device
Class 1
Type BF device
UR time-lag fuse (conforms to UL standard)
Record of equipotential
Connector for CO2 port
Date of manufacture MM/YYYY
Manufacturer
Complies with European directive 93/42/CEE
Electric or electronic device launched on the
market after 08/01/05
10. TECHNICAL SPECIFICATIONS
Pneumatics:
• CO2 gas supply system:
- DIN 477-1 no. 6 or US 7/16” connector
- Maximum permitted pressure of 70 bar
• Maximum flow without loss of head (to the nearest decilitre):
- 20 to 45 l/min in high flow (depending on the model)
- 2 l/min in low flow
• Blow-off pressure: 0 to 24 mmHg to an accuracy of 1mmHg
PAGE 17