System Housing
0-15
Upgrading to Two Redundant Power Supply
Modules
Follow the instructions in this section when you want to upgrade to
two 420W redundant power supply modules.
To reduce the risk of electric shock, make
sure to disconnect all power supply cables
from the wall socket before opening the
system housing.
Removing the Existing Power Supply
1.
Unplug the AC power cable from the wall socket, then remove
the plastic fan cover on the rear panel.
2.
Open and remove the lower front and left doors. See the
Opening the Housing Panels section for more information.
3.
Remove the three screws that secure the right door.
DO NOT open the RIGHT door at this
moment! Doing so will damage the power
sharing board and cables attached to its
inner side.
4.
Unplug the connectors
- from the power supply to the power sharing board
- from the power sharing board to the system board
- from the power sharing board to the disk drives
- from the fans to the system board
Remember where you unplugged each connector. You will have
to reconnect them later.
Содержание Veriton 9100
Страница 1: ... FHU OWRV System Guide ...
Страница 41: ...0 28 Altos 9100B System Guide Connecting External Devices Connecting a Monitor ...
Страница 42: ...System Housing 0 29 Connecting a Keyboard ...
Страница 43: ...0 30 Altos 9100B System Guide Connecting a Mouse ...
Страница 44: ...System Housing 0 31 Connecting a Printer ...
Страница 45: ...0 32 Altos 9100B System Guide Complete System Connections ...
Страница 79: ...CPU Board 2 15 4 When you have released both clips take off the processor heatsink and fan ...
Страница 131: ...LCD Module Event Log List A 1 ...