OSD (On-Screen-Display) Controls |
87
Value Range (ASCII Bytes)
Wait Response
Time (ms)
Remark
(1) Input value: Byte1-Byte-
Byte3…Byte15.
Byte2 to Byte11=0x00
Byte1=0x03: Get Model Name
Byte1=0x04: Get Scaler Firmware
Version
Byte1=0x05: Get LAN Firmware
Version
Byte1=0x07: Get Firmware Built
Date
Byte1=0x08: Get Firmware Built
Time
Byte1=0x09: Get Panel Info.
(2) Return value: Byte1-Byte2-
Byte3…Byte15.
The Byte1 value at the return value
should be the same as the value of
Byte1 at input value.
Byte2 to Byte15 should be in ASCII
format.
Example 1: If Customer=Generic,
Byte1=0x01, Byte2='G',
Byte3='e',...Byte8='c', Byte9 to
Byte11=0x00.
Example 2: If the Scaler Firmware
Version=1.02, Byte1=0x03,
Byte2='1', Byte3='.', Byte4='0',
Byte5='2', Byte6 to Byte11=0x00.