Acer S205F / S200F User’s Manual
38
2.12.2 Procedure
1
Attach the power cord to the Power Supply/Cooling Modules,
2
Attach the power cord to the in-line IEC connector in this cord.
Caution
These power splitting cables are provided so that the system is operated from a SINGLE power
source thus providing a single point of disconnect.
3
Switch on each Power Supply/Cooling Module.
4
A POWER LED on the Ops Panel indicates whether AC power is present.
Caution
The power connections must always be disconnected prior to removal of the Power Supply/Cooling
module from the enclosure.
2.13 Grounding Checks
Perform these checks to ensure that a safe grounding system is provided.
• If a rack distribution system is being used.
– Ensure power is removed from the rack.
– Connect the Altos S205F / S200F Storage System power cord to the rack distribution and the
enclosure.
• If a direct connection is made with the Altos S205F / S200F Storage System power cord, ensure
that it is connected to the enclosure.
Warning
Some electrical circuits could be damaged if external signal cables or power control cables are
present during the grounding checks.
• Check for continuity between the earth pin of the IEC 320 connector on one of the Power
Supply/Cooling modules and any exposed metal surface of the Altos S205F / S200F Storage
System enclosure.