VI. NON-NORMAL OPERATION 

If either the batteries or the generating source become depleted, or the 
generating source is removed from the MiniBump, the instrument enters 
a non-normal operating condition and the RED LED will turn on. 

 

Under  a  low  battery  condition,  the  RED  LED  will  begin  to  flash. If  the 
low battery condition occurs during power up, the RED LED will flash for 
approximately 30 seconds and then the instrument will power down.  If the 
low battery condition occurs after start up, the RED LED will begin 
flashing and the instrument will continue to run for approximately 30 
seconds before power down. It is recommended to replace depleted 
batteries with two 'AA' heavy duty alkaline batteries for maximum 
operating life. 

 

If the source becomes depleted or is removed, the RED LED will light 
continuously. If the depleted source condition occurs during power up, 
the RED LED will remain on for approximately 30 seconds and then the 
instrument will power down. If the depleted source condition occurs 
after start up, the RED LED will light and the instrument will continue to 
run for approximately 30 seconds before power down. 
 

If the source has been depleted, it should be removed and replaced 
with a new generating source.  Please refer to the section on source 
life for proper instructions on replacing the generating sources.  If 
the source has not been depleted, there may be a faulty electrical 
connection between the source and the instrument.  Remove the 
source and inspect the pins protruding from the source and the 
sockets in the source chamber.  Remove any debris and or corrosion 
that may be present and retest the source.  If either the pins or 
sockets become damaged or non-repairable, replace the source 
chamber and/or the source.

 

 

 

Содержание MiniBump

Страница 1: ...lephone 520 290 2855 Fax 520 290 2860 TollFree 800 737 0223 Email acd goACD com Web www goACD com P N 910 0550 00 Rel IV AdvancedCalibrationDesigns Inc InstructionManual CalibrationGasBumpTester Advan...

Страница 2: ...nstrument correctly can lead to improper testing of your detection system This instrument conforms to the protection requirements of the EC DIRECTIVE 2014 30 EU on Electromagnetic Compatibility EMC in...

Страница 3: ...2...

Страница 4: ...5 Electrochemical Generating Source 5 Alkaline A Batteries 5 Microprocessor Based Circuitry 6 II START UP MINIBUMP SOURCE 7 III NORMAL OPERATION MINIBUMP SOURCE 8 IV START UP MINICAL SOURCE 9 V NORMAL...

Страница 5: ...4...

Страница 6: ...lectrochemically generated gas The Release IV MiniBump instruments are designed to operate at 5 LPM liters per minute Electrochemical Generating Source The electrochemical generating source contains a...

Страница 7: ...wered up the microprocessor checks for what type of generating source is inserted the gas type and concentration as well as if the source is a bump type source and the remaining source life It also mo...

Страница 8: ...ll begin running With a bump source installed the unit will run for an additional 20 seconds providing a bump of output gas to drive the connected sensor into alarm after which both red and green ligh...

Страница 9: ...rce is consumed If either condition occurs a RED LED will light indicating a non normal condition refer to the Non Normal Operation section that follows The calibration gas is delivered through a smal...

Страница 10: ...ting the unit is ready to calibrate With a MiniCal source installed the unit will continue to run in this state generating the concentration and type of gas specified by the generating source installe...

Страница 11: ...as is delivered through a small flexible hose attached to the source manifold cap The hoseis placed over around or in front of the gas sensor Alternatively the detector can be placed directly in front...

Страница 12: ...oved the RED LED will light continuously If the depleted source condition occurs during power up the RED LED will remain on for approximately 30 seconds and then the instrument will power down If the...

Страница 13: ...t numbers please refer to the parts list to follow To replace the generating source in the instrument first remove the instrument cap located on the top of the instrument The generating source pulls d...

Страница 14: ...altitude and temperature can cause changes in air density thus affecting the output of the MiniCal source The output was calibrated to STP standard temperature and pressure of sea level and 20 C To co...

Страница 15: ...he MiniBump instrument contain corrosive chemicals While it is not expected that the chemicals in the source or alkaline batteries will leak during normal operation it is recommended that both the sou...

Страница 16: ...e 510 0550 02 Hydrogen Sulfide MiniBump source 510 0570 02 Hydrogen Cyanide MiniBump source 510 0590 02 Hydrogen MiniBump source 510 0401 0x Chlorine MiniCal source specify PPM 1 25 510 0405 0x Hydrog...

Страница 17: ...d Calibration Designs Inc s obligation under this warranty shall be limited to repairing or replacing and returning any product which shall be returned toAdvanced Calibration Designs Inc at its manufa...

Страница 18: ...le electrochemical MiniCal sources and their standard warranty when installed in equipment manufactured and supplied by Advanced Calibration Designs Inc Chlorine Hydrogen Hydrogen Sulfide Hydrogen Cya...

Страница 19: ...anufactured by Advanced Calibration Designs Inc 2024 W McMillan Street Tucson Arizona 85705 USA Phone 520 290 2855 Fax 520 290 2860 Int l Phone 001 520 290 2855 Fax 001 520 290 2860 Website www GoACD...

Страница 20: ...lephone 520 290 2855 Fax 520 290 2860 TollFree 800 737 0223 Email acd goACD com Web www goACD com P N 910 0550 00 Rel IV AdvancedCalibrationDesigns Inc InstructionManual CalibrationGasBumpTester Advan...

Отзывы: