EVO 150 Controller
14
12
Excessive web curl.
If web flutter or curl exists, change parameters 6 and
18 to higher values. Refer to page 21 for more information about setting
controller parameters.
13
All actuators.
End-of-travel mode is incorrect.
Set parameter 2 to the
correct value. Refer to page 21 for more information about setting controller
parameters.
14
All actuators.
Actuator cable wires are broken, shorted or connected
to wrong terminals of J6 or J7.
Refer to the connection diagrams on page
121. Check wiring at J6 and J7 and check the actuator cable for broken or
shorted wires.
15
Actuators with potentiometer feedback (MT, SF, and HF).
End-of-travel
limits not set correctly.
See the Settings Screen, Actuator Settings to
adjust the limits (Parameters 9 and 10). The limits must be adjusted to stop
the actuator before the web guide or actuator hits any obstruction.
16
Actuators with potentiometer feedback (MT, SF, and HF).
Potentiometer failure.
Refer to the potentiometer replacement procedure
on page 86.
17
Actuators with limit switches (MME and MNE).
Limit switch failure.
Check the limit switch voltage at J7 terminals 2 and 3 (terminal 4 is GND).
This voltage should normally be 0.0 VDC (switch is closed), then jump to
+3.3 VDC when the limit is reached (switch opens). If the correct voltages
are not present, replace the limit switch in the actuator or return the
actuator for repair.
18
Actuators with limit switches (MX).
Limit switch failure.
The end-of-
travel limit switches in the MX-series actuators directly control the motor
circuit and cannot be monitored externally. If a limit switch has failed,
replace the switch or return the actuator for repair.
19
Reversed motor wires.
Restore the motor wire connections at J6
terminals 1, 2 and 3 to the proper connection. Refer to the connection
diagrams on page 121. Change the value of parameters 3, 4, or 50 as
required. Refer to page 21 for more information about setting controller
parameters.
20
Edge detector not calibrated.
Refer to page 57 for calibration instructions.
21
Edge detector:
transducers covered with dust or other material.
Clean
the edge detector transducer face with a cloth dampened with water or a
mild detergent solution. If the contamination cannot be removed with this
method, return the edge detector for repair.
Digital line guide:
optics covered with dust or other material.
Clean the
underside of the sensor with a soft cloth dampened with water or a cleaning
solution suitable for photographic lenses. If the contamination cannot be
removed with this method, return the sensor for repair.
22
Reserved for future use.
23
Auto-mode speed limit setting is incorrect.
Change the value of
parameter 7. Refer to page 21 for more information about setting controller
parameters.
24
Manual-mode speed setting is incorrect.
Change the value of parameter
8. Refer to page 21 for more information about setting controller
parameters.
Содержание EVO 150
Страница 1: ...P O Box 7816 Madison Wisconsin 53707 7816 Instruction Manual EVO 150 Web Guide Control System...
Страница 2: ......
Страница 6: ...EVO 150 Controller 4 EVO 150TM Web Guide Control System...
Страница 56: ...PointSource and WideArray Edge Detectors 54 PointSource and WideArray Edge Detectors...
Страница 62: ...AccuBeam 3 Digital Line Guide Sensor 60 AccuBeam 3 Digital Line Guide Sensor...
Страница 85: ...AccuWeb Linear Actuators 83 AccuWeb Linear Actuators...
Страница 90: ...Remote Station Guide Point Adjust 88 Remote Station Guide Point Adjust...
Страница 99: ...Remote Station Auxiliary 97 Remote Station Auxiliary...
Страница 104: ...Fieldbus Interface 102 Fieldbus Interface...
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ...NOTES...