EVO 150 Controller
9
4. Electrical
Power
Note:
Electrical power must be provided from a customer-supplied 24VDC isolated source
power supply. Connections must comply with NEC 590 and other local codes.
Use only a hard-service or junior hard-service flexible cord.
a) Verify that the power source is
off
and locked out.
b) Install the electrical power cord through the cord grip.
c) Connect the cable ends to the terminal block located inside the enclosure.
d) Make sure the circuit board is free of metallic debris such as screws, lockwashers, and
wire strands.
e) If any of the cables have been removed, shortened, or modified in any way, make sure
the conductors are prepared and connections agree with the appropriate connection and
wiring diagrams located on page 121.
5. Static
Test
a) Apply power to the system.
b) Press the MANUAL button.
c) Press the IN and OUT buttons several times. The actuator and web guide mechanism
should move freely and without hesitation.
d) Press and hold the IN button. When the guide mechanism gets near the In limit, release
the button.
e) Jog the IN button repeatedly until the actuator automatically stops at its end-of-travel
limit.
Caution:
If the actuator or web guide mechanism hits a mechanical obstruction before
the actuator stops automatically at its end-of-travel limit, release the button immediately.
Continued activation will cause serious damage to the actuator motor and/or guide
mechanism. See Troubleshooting on page 12, item’s #13 through 19.
f) Repeat the previous two steps using the OUT button in order to check the Out limit.
g) Press the SERVO-CENTER button and verify that the actuator drives to the center of its
stroke.
6. Dynamic
Test
a) Press the SERVO-CENTER button and verify that the actuator drives to the center of its
stroke. This also places the web guide in its center (or
tram
) position.
b) Thread the web through the machine and put a slight tension on it so that the web is in its
normal operating position.
Repeat steps c) through h) for each sensor:
c) Press the SERVO-CENTER button.
d) Position the sensor.
Edge detector:
Place at the edge of the web. The edge detector’s null indicator LED will
turn off when the edge detector is positioned correctly. The scribed lines on the edge
detector indicate the approximate location of the detector’s guide point.
Содержание EVO 150
Страница 1: ...P O Box 7816 Madison Wisconsin 53707 7816 Instruction Manual EVO 150 Web Guide Control System...
Страница 2: ......
Страница 6: ...EVO 150 Controller 4 EVO 150TM Web Guide Control System...
Страница 56: ...PointSource and WideArray Edge Detectors 54 PointSource and WideArray Edge Detectors...
Страница 62: ...AccuBeam 3 Digital Line Guide Sensor 60 AccuBeam 3 Digital Line Guide Sensor...
Страница 85: ...AccuWeb Linear Actuators 83 AccuWeb Linear Actuators...
Страница 90: ...Remote Station Guide Point Adjust 88 Remote Station Guide Point Adjust...
Страница 99: ...Remote Station Auxiliary 97 Remote Station Auxiliary...
Страница 104: ...Fieldbus Interface 102 Fieldbus Interface...
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ...NOTES...