Accurex Grease Grabber H2O XGH2O Скачать руководство пользователя страница 18

18

Model XGH2O

Timer Programming –  

24 Hour / 7 Day

Setting the Clock

1.  Press and hold the CLOCK button.
2.  Press and hold the DAY button until the display 

shows the current day.

3.  Press the HOUR button until the display shows the 

current hour.

4.  Press the MIN (minute) button until the display 

shows the current minute.

Setting the Programs

1.  Press the PROG (program) button once. You will 

now set the time in which you want the wash to 
start. The number 1 in the lower left hand corner 
indicates that you are now programming Event 1.

2.  Press the DAY button repeatedly until the display 

shows the day(s) when you want the timer to turn 
on. The options are:

  -

 Days of the week

 

    MO, TU, WE, TH, FR, SA, SU

  

- Individual days of the week

 

    MO etc.

  -

 

Weekdays only 

    MO, TU, WE, TH, FR

  -

 

Weekends only

 

    SA, SU

3.  Press the HOUR and MIN (minute) buttons to set 

the time when you want the timer to turn on. 

4.  Press the PROG (program) button again.
5.  Repeat steps 2-4 to set the OFF time for Event 1. 

This should be set one minute after the ON time.

6.  When programming is complete, press the CLOCK 

button to display the current time.

Things you should know about programming events: 

•  You can repeat the ON and OFF programming 

procedures outlined above for up to seven (7) 
events as needed.

NOTE

While setting events, the timer may prematurely turn 
on the load, if you press the 

MODE

 button.  

  •  Three kinds of settings can cause the timer to 

work in an unexpected way:

 

a.  Set up events in progressive order of time, for 

example:

 

 

8:00 pm ON, 9:00 pm ON, 10:00 pm ON 

 

Not

 

8:00 pm ON, 10:00 pm ON, 9:00 pm ON

 

b.  Do not overlap event times, for example:

 

 

 8:00 pm ON / 12:00 pm OFF and  
9:00 pm ON / 11:00 pm OFF

 

c. Set the OFF time for one minute after the ON 
time.

Reviewing Events Programmed

In your current time display, press the PROG (program) 
button repeatedly to check your settings.
When finished, press the CLOCK button to return the 
display to the time of day.

Clearing (Deleting an Event)

1.  Press the PROG (program) button as many times 

as necessary to locate the setting you want to 
clear.

2.  Press and hold the MODE button.
3.  Press the PROG button to clear the setting.
4.  When finished, press the CLOCK button to return 

the display to the time of day.

Operating the Time Switch

Press the MODE button repeatedly to set the timer to 
Automatic, Random or Manual mode.

NOTE

For the time switch to run programmed events, it 
must be set to AUTO mode.

•  

AUTO

 runs all events automatically according to the 

schedule you have set. The word AUTO appears in 
the display. 

•  

RND

 (random) runs all events in a RANDOM mode. 

This is a security feature in which ON and OFF 
times randomly /- 15 minutes from the 
programmed times, creating a more “lived-in” look. 
The word RND appears on the display. 

NOTE

Do NOT set this timer to RND mode. It will not wash 
at the exact time you programmed.

•  

MANUAL

 turns ON and OFF only when the user 

presses the ON or OFF button. The display is blank, 
showing neither RND or AUTO.

Overriding Timer Settings

The ON or OFF buttons override the current 
programmed events. To override the current program 
(either ON or OFF), press the ON or OFF button. 

Содержание Grease Grabber H2O XGH2O

Страница 1: ...prevent accidental power up CAUTION When servicing the unit motor may be hot enough to cause pain or injury Allow motor to cool before servicing Installation Operation and Maintenance Manual Please re...

Страница 2: ...each item have been received If any items are missing report shortages to your local representative to arrange for obtaining missing parts Sometimes it is not possible that all items for the unit be s...

Страница 3: ...ically engaged to run at the same time each day through a programmable timer Grease Grabber H2O System Function Table of Contents Grease Grabber H2O System Function 3 Cleaning Cycle Manual and Automat...

Страница 4: ...r and detergent will fill the hood reservoir The soapy water will then be cycled through the hood by the attached recirculation pump cleaning both the filter banks and the exhaust plenum area on a tim...

Страница 5: ...ILL DETERGENT After pressing CLEAN HOOD Fans will automatically stop 472617 In case of emergency the wash cycle can be stopped by pressing CLEAN HOOD CLEAN HOOD FAN ON OFF SYSTEM FAULT FILL DETERGENT...

Страница 6: ...on process 1 2 3 Profile of Hood Profile of Hood Profile of Hood Profile of Hood Remove side back and top lumber Remove 3 inch lag screws Holding the front lifting skid in place and position the skid...

Страница 7: ...r must be contacted at this time After the fire system has been installed mount the enclosures then the supply plenums If an Horizontal Supply Plenum is provided it should be installed before the encl...

Страница 8: ...u clips and bolts Caulk this joint with NSF Approved silicone caulk GE SCS1000 or its equivalent The caulk is not provided NOTE Before hanging the hoods please verify the hood marks to make sure the...

Страница 9: ...ion instructions now Supply Supply ductwork where applicable should be connected to the hood in a manner approved by the local code authorities For proper installation of duct collars when they are sh...

Страница 10: ...in mm in mm ft m Back Supply 35 0 15 878 6 152 4 Variable Variable 3 to 16 91 to 4 88 145 cfm ft 246 36 m3 hr Air Curtain Supply 14 inch 9 5 4 31 14 355 6 10 254 3 to 16 91 to 4 88 110 cfm ft 186 89 m...

Страница 11: ...STED LOCATION ABOVE CUT 1 4 in X 24 in OPENING AT CENTERED ON WIDTH OF THE SUPPLY IF MODULE 6 ft STEP 1 4 in TO 6 in FASTEN WITH S PLACE THE DU L MODULE LENGTH L 2 L 2 L 2 L MODULE LENGTH L 4 L 4 STEP...

Страница 12: ...UPPLY IF IT WILL NOT INTERFERE 2 BEFORE THE HOOD IS HUNG THE BACKSUPPLY MUST BE SECURED INSTRUCTIONS AND THE FOLLOWING PROPERLY AS DESCRIBED IN STEP 3 in STEP 4 5 Connect the remaining ductwork for th...

Страница 13: ...provided Note Installation instructions may not be applicable for concrete ceilings Installing End Skirts 1 After the hood is hung in position slide the hemmed form on top of the end skirt onto the e...

Страница 14: ...PIECES PANELS UP TO 48 IN 1219 2 MM WIDE SHIP IN ONE PIECE OVER 48 IN 1219 2 MM IN MULTIPLE PIECES Length 1 inch 25 4 mm Heigth Length Height 1 After the hood is hung in position slide the flat flang...

Страница 15: ...nnection Exhaust duct connection is to be a continuous liquid tight weld to hood Supply Duct Connection Supply duct connection to be tack welded with 1 to 2 inch tacks or sheet metal screws at 3 to 6...

Страница 16: ...detergent is non caustic and biodegradable waste water from the hood can be drained in any typical grease trap A One inch unions B Detergent tank C Mounting plate D Isolators qty of four E Detergent...

Страница 17: ...facturer for use in the wash system Use Formula G 510 full strength This product is biodegradable non caustic and safe for kitchen staff to use If G 510 detergent is not used the cleanliness of the ex...

Страница 18: ...ive order of time for example 8 00 pm ON 9 00 pm ON 10 00 pm ON Not 8 00 pm ON 10 00 pm ON 9 00 pm ON b Do not overlap event times for example 8 00 pm ON 12 00 pm OFF and 9 00 pm ON 11 00 pm OFF c Set...

Страница 19: ...se valve until water mist is no longer felt above equipment Once the valve is set it will not need to be moved again Verify the Grease Grabber H2O sequence of operation see the diagram of wash sequenc...

Страница 20: ...pump OFF Spray for 5 minutes Spray for 5 minutes 20 minute dry time Wash rinse dry complete No Temperature Interlock Exhaust Mode in Fire STOP Exhaust Mode in Fire RUN No Yes Shut OFF exhaust fan s T...

Страница 21: ...x 4 846 x Average inlet slot velocity x 2 47 144 Average Velocity Sum of Velocity Readings Number of Readings Hood Length 48 to 72 inches 72 to 120 inches 120 to 192 inches Minimum Number of Test Loca...

Страница 22: ...MICROSWITCH IN NORMAL INSTALLATION THE YELLOW WIRE IS TO BE USED ONLY FOR EXTINGUISHER ALARM LIGHTS CIRCUITS ETC L1 L2 PUSHBUTTON SWITCH 120V 60HZ K1 Ka K1b CURRENT DRAW MAX 8A RESISTIVE 8A INDUCTIVE...

Страница 23: ...WITH ANSUL ANSUL SNAP ACTION SWITCH BLACK RED NEUTRAL HOT 1 L2 L NOTE ANSUL file name Typicalwiringschematicelectricequipmentshutdowndetail ai File received on August 4 2010 TEMPERATURE RATING 110V 6...

Страница 24: ...K RD 12 GA 12 GA 12 GA 18 GA 18 GA 18 GA 18 GA BK BK BK BK N WHT BL BL PR PR PR PR PR BR PR PR PR 18 GA YW YW YW 12 GA 18 GA PR PR R6 120 VAC Wash Timer Relay A1 A2 T1 T2 Timer Contact BK RD BK N WHT...

Страница 25: ...ing the filters Ensure no gaps are between filters after installation If any filter appears damaged consult factory for replacement Floats The floats need to be inspected two weeks after start up and...

Страница 26: ...ks water leaking through the access panels when filling Ensure access panels are securely in place If leak persists partially close inlet water ball valve by others upstream of fill solenoid to reduce...

Страница 27: ...guide on page 26 Grease Grabber H2O Start Up Checklist Check boxes when item has been verified and gone over with customer Hook Up o Electrical Connected 120V 1 30A to terminals L1 and N for wash cont...

Страница 28: ..._______________________________ Date___________________ Time______________ AM PM Notes ___________________________________________ _________________________________________________ ___________________...

Отзывы: