RFR-02 READER TEST PROCEDURE
______________________________________________________________________________
THIS IS A CONTROLLED COPY ONLY IF STAMPED “CONTROLLED COPY” IN RED.
©
Accu-Sort Systems, inc.
7.26
Measure the frequency.
7.26.1 Plug the BNC connector into the universal counter on port “CHA 100 MHz”.
7.26.2 Frequency light must be lit.
7.26.3 Make sure channel A is lit and the gate is at 1 µsec.
7.26.4
Record the frequency.
The frequency should be 13.56MHz ± 500Hz.
7.27
Plug the BNC connector back into the input port on the Spectrum Analyzer.