CALIDO1 

DHW heat pump with tank

28

If the unit is disconnected from the power supply, the disinfection cycle will not occure. If the unit has been without power 

for an extended period of time, DO NOT use the water contained in the unit.

It is recommended that the tank be emptied and all water contained in the system piping carrying the DHW be drained. It 

is recommended to let the water flow not only to renew all the water in the pipes but also for a sufficient time to flush the 

pipes. This necessary "flushing" time is inversely proportional to the temperature of the water flowing through the pipes.
The disinfection cycle occurs only inside the water tank. Therefore, it’s recommended to perform a recirculation of the water 

system especially for disinfecting all the contained water. If cannot be possible, according to the preceding warning, it is 

recommended to let the water system to flow for a enough for cleaning the pipes and renewing the water.

If the parameter 5 (t2) is set to be 0, the disinfection function is disabled. Such operation is strictly unrecommended; the 

manufacturer declines any responsibility for the data caused by a lack or incorrect unit disinfection. If you desire to disable 

the disinfection cycle, you should ask the maintainer about the consequences that may arise from this operation.
It is strictly forbiden to change the default value of parameter 4. The parameters 4 and 5 control the anti-legionella cycle 

(temperature vs time). We recommend to respect the above guidelines, if you want to change them. Please remember that 

to keep the temperature of the tank water between 55-60°C in order to inhibit the bacterial proliferation (see Annex 13 of 

the guidelines mentioned above).

The parameter 21 acts on the frequency of disinfection cycles. It must be properly set according to the storage temperature 

of the tank and the frequencies of DHW utilization. Higher frequency of the disinfection cycle, results in a lower possibilities 

of bacteria contact.

The stagnant water allows Legionella bacteria to grow. For this reason it is necessary to properly valuate the frequency of 

the disinfection cycle according to its own uses.

The plant designer must keep in mind the legionella risk and should adopt all the measures for prevention and control of 

water.

The user is RESPONSIBLE to periodically check the correct operation of the anti-legionella cycle and to verify that during the 

disinfection, the setting temperature parameter is put to be 4 and is reached for the duration indicated by the parameter 5.

11.4.6 

Auxiliary electric resistance

Electric resistance on or off, condition 1:

(when the unit is switched on, and the electrical resistance has not been switched on manually using the relevant button)

1. ON:  when  tank  temperature  set  TS1  (parameter  0)  is  greater  than  the  operating  limit  expressed 

in Section 16, the lower temperature of tank T2 reaches this limit and the upper temperature of tank T3 ≤ TS1-3°C; 

 

OFF: when the upper tank temperature T3 reaches temperature set TS1+1°C.

2. ON: when the ambient temperature ≤ -10°C or > 44°C; 

 

OFF: when the ambient temperature ≥ -8°C or < 42°C.

3. ON: when high or low gas pressure protection is triggered three times in 30 minutes; 

 

OFF: when the gas pressure protection has triggered for the third time, the corresponding error code is displayed, and this protection cannot 

be reset until the unit is disconnected and restarted. The resistance continues to operate to reach the set temperature, then it is switched 

off.

4. ON: when the unit enters defrost (only if parameter 20 is set to 1=on) or disinfection; 

 

OFF: when the unit exits defrost or disinfection.

The resistor integration function described in point 1 of condition 1 can be deactivated via parameter 32 (see paragaph 11.5).

Electric resistance on or off, condition 2:

(when the unit is switched on and the electric resistance has been switched on manually using the relevant button)

1. ON: the running time of the compressor exceeds the delay time of the heater (parameter 3), and the upper tank temperature T3 ≤ TS2-3°C;

 

OFF: upper tank temperature T3 ≥ TS2+1°C.

Electric resistance on or off, condition 3:

(when the unit is switched off but powered, namely in standby mode)

1. ON:  If  the  electric  resistance  has  been  switched  on  manually  using  the  corresponding  key,  it  will  operate  until  the  upper 

tank temperature T3 reaches set TS2; 

 

 

 

 

 

 

 

 

 

 

OFF: the electric resistance was switched off manually using the button or the upper temperature of tank T3 has reached set TS2.

2. ON: Upper tank temperature T3 ≤ 5°C (tank frost protection); 

 

OFF: upper tank temperature T3 ≥ 10°C or the unit is switched on.

When the heater is switched on manually using the heater key, TS2 (heater off temperature) appears on the display and can 

be changed directly instead of TS1 (tank temperature set).

Содержание GREEN 220

Страница 1: ...GREEN 220 220 S 220 DS Monobloc heat pump water heater with domestic hot water storage tank for internal installation GREEN 220 220 S 220 DS INSTALLATION MANUAL...

Страница 2: ...CALIDO1 DHW heat pump with tank 2 15 11 2021 AL B A R Add data kboll of the tank update layout Rev Date Edited by Approved by Notes Code Serie MUI01110D6120 DHW heat pump with storage tank...

Страница 3: ...IES 10 6 TECHNICAL CHARACTERISTICS 10 7 ITEMS CONTAINED INSIDE THE PACKAGING 10 8 OVERVIEW OF THE UNIT 11 8 1 PARTS AND DESCRIPTIONS 11 8 2 DIMENSIONS 11 8 3 CABLE GLANDS 13 8 4 HOW TO REPLACE THE MAG...

Страница 4: ...ALFUNCTION AND ERROR CODES 30 12 MAINTENANCE AND PERIODICAL CONTROLS 31 12 1 ENVIRONMENTAL PROTECTION 31 13 TROUBLESHOOTING 32 14 DECOMISSIONING 32 15 TECHNICAL CHARACTERISTICS 33 16 HEAT PUMP OPERATI...

Страница 5: ...sent to the customer must be kept as an annex to this manual regarding the use and maintenance of its machines 1 2 GRAPHIC SYMBOLS USED IN THE MANUAL ment in complete safety 2 NORMATIVE REFERENCES ise...

Страница 6: ...and or lean on any type of object Do not spray or pour water directly on the device supply Do not place your hands or insert screwdrivers spanners or other tools on moving parts 4 1 WORKERS HEALTH AND...

Страница 7: ...mask and protective goggles must be used during cleaning operation 4 3 SAFETY SYMBOLS The unit includes the following safety signs which must be followed by personnel General hazards Electric shock h...

Страница 8: ...rameters AEL 8 h and 12 h TWA 1000 ml m3 Respiratory protection Use self contained breathing apparatus for rescue and maintenance work in tanks Vapours are heavier than air and can cause choking by re...

Страница 9: ...vviso CALIDO Air inlet Air outlet GREEN Air inlet Air outlet Storage room cooling the unit can be placed in the storage room as the low temperature helps to keep the food fresh the unit can be located...

Страница 10: ...ACCESSORIES ONE FL ONE SAS temperature probe with 5 m cable GREEN S and GREEN 2S 6 TECHNICAL CHARACTERISTICS Safety devices for high and low gas pressure even in extreme cold winters 7 ITEMS CONTAINE...

Страница 11: ...CALIDO1 DHW heat pump with tank 11 8 OVERVIEW OF THE UNIT 8 1 PARTS AND DESCRIPTIONS 8 2 DIMENSIONS GREEN 200 GREEN 200 S GREEN 200 2S I A B C F E D H G L O N M Q P...

Страница 12: ...124 1124 1124 C 1062 1062 1062 D 262 E 747 747 747 F 932 932 932 G 30 H 160 I 706 L 655 M 258 258 N O 692 692 P 787 Q 927 AIR CONNECTION QUOTAS 318 80 148 170 GREEN 220 GREEN 220 S GREEN 220 2S POS DE...

Страница 13: ...ature 15 Solar water inlet G 1 female 16 Solar exchanger coil 1 2 m2 17 Auxiliary heat source outlet G 1 female 18 Auxiliary heat source inlet G 1 female 19 Auxiliary heat source coil 0 5 m2 8 3 CABLE...

Страница 14: ...astic frontal cover Such control allows a variation of temperature between 15 and 75 C each notch corresponds to a temperature variation of 10 C The factory setting is set to its maximum value 75 C a...

Страница 15: ...s of the extent of the damage The Customer should prepare a written statement of any severe damage Please note that all the installation diagrams shown in this chapter are only a guide The correct ins...

Страница 16: ...supply must always be OFF when cleaning or servicing the unit Failure to do so may result in injury due to high fan speed or electrical shock In case the unit is used without an exhaust air duct chec...

Страница 17: ...unit can be inclined only on the opposite side of the handle see above drawing namely only on the left hand side of the control panel The unit is equipped with a handle to make easy the transport The...

Страница 18: ...oss will be larger So if there are two bending pipes the total lenght of the ducts should not be longer than 2 m Please note that the performance of the unit are reduced in the case the air inlet is c...

Страница 19: ...of the hydraulic circuit All hydraulic connections must be insulated using closed cell material of adequate thickness The units should be connected to the piping using flexible couplings It is recomme...

Страница 20: ...here below The Parameter no 14 must be configured by the installer 1 hot sanitary water circulation 2 solar water circulation The circulation of hot sanitary water is useful to avoid water becomes col...

Страница 21: ...ly for GREEN 200 units it s possible to connect a third energy source for example an external boiler In this case the installer must discon an external relay not supplied to the external heat source o...

Страница 22: ...ts otherwise the warranty will expire immediately Before ATTENTION The supply voltage must not change by more than 10 of the nominal value If this tolerance is not respected please contact our technic...

Страница 23: ...ulations in force including grounding Check that the electrical voltage is within the tolerance 10 of the rating plate value Check that there are no gas leaks Before switching on the unit check that a...

Страница 24: ...creen 2 Button Pressing this button for 2 when the unit is in standby mode the unit switches on and operates in the selected mode The operating mode temperature set point and water temperature time an...

Страница 25: ...t the same time and for 5 seconds again the and buttons all the buttons are unlocked 4 Buttons and Clock setting Press button to entry the clock setting interface hour icon 88 88 flashes Press the and...

Страница 26: ...active This is an automatic function the system will enter or exit defrosting according to its own internal control logic Defrosting parameters cannot be changed on site And the unit does not support...

Страница 27: ...nk water goes up to 85 C the unit will stop and the relating error code will be shown on the controller This is an auto reset protection When tank water temperature goes down the unit can start again...

Страница 28: ...water The user is RESPONSIBLE to periodically check the correct operation of the anti legionella cycle and to verify that during the disinfection the setting temperature parameter is put to be 4 and...

Страница 29: ...Adjustable 5 l High temperature disinfection time t2 30 90 min 30 min Adjustable 13 l Start disinfection time 0 23 23 Adjustable 14 l Pump use 0 1 2 0 Adjustable 0 disabled 1 hot water recirculation 2...

Страница 30: ...t working properly 1 P8 appears at 125 C and disappears at 120 C 2 Check and replace the sensor if necessary High pressure protection Pressure switch HP E1 6 flashes 1 off 1 Air inlet temperature too...

Страница 31: ...nge x Check the correct operation of the electrical resistance for the anti legionella cycle It is advisable to carry out a diagnostic of all the hydraulic system with sampling of the system water at...

Страница 32: ...operations are recommended the refrigerant must be recovered by qualified personnel and sent to collection centres lubricating oil from compressors should also be recovered and sent to collection cen...

Страница 33: ...ace m2 Auxiliary exchange coil surface m2 m3 h m3 h Maximum exchange coil pressure bar Exchange coil material Cold water inlet inch Hot water inlet inch inch inch Condensate water outlet Condensate dr...

Страница 34: ...65 C 1 Technical label values referred to integration with boiler in accordance with DIN 4708 norms primary 80 60 C secondary 10 45 C 2 Measured according to EN 12102 standard in the conditions of EN...

Страница 35: ...CALIDO1 DHW heat pump with tank 35 17 WIRING DIAGRAM Please refer to the wiring diagram inside the electrical box cover 17 1 STANDARD CONNECTION...

Страница 36: ...CALIDO1 DHW heat pump with tank 36 17 2 CONNECTION OF AN AUXILIARY POWER SOURCE...

Страница 37: ...CALIDO1 DHW heat pump with tank 37 17 3 CONNECTION OF AN AUXILIARY ENERGY SOURCE VIA AN EXTERNAL SELECTOR SWITCH...

Страница 38: ...200 2S L A 129 119 111 104 796 kWh 862 kWh 921 kWh 983 kWh 55 C 58 dB A the dedicated chapters in the user installer manual 19 TECHNICAL PARAMETERS EU REGULATION 814 2013 Models Qelec Indor air 20 C I...

Страница 39: ......

Страница 40: ...tolo puramente indicativo la A2B Accorroni E G S r l si riserva di apportare eventuali modi che senza alcun preavviso web site www accorroni it e mail a2b accorroni it A2B Accorroni E G s r l Via d An...

Отзывы: