page 23
8. REPLACING PARTS
Since specific technical skills are required
to replace the parts listed below, it is
recommended to advise the user to always
contact skilled technical personnel. For safety
and quality reasons, it is recommended to
use original spare parts when replacing
components.
WARNING! All the following operations must
be carried out while the heater is turned off,
disconnecting the gas and electric supplies.
8.1 CONTROL EQUIPMENT
Disconnect the cables by pulling on the terminals
and extracting the connectors, releasing them
first from the special retainer. Replace the
equipment, placing it in the special insert and
attaching it using the self-threading screw. Insert
the terminals and the connectors into their
respective housings
(fig. 24).
8.2 FUSE
Using a special tool, remove the fuse holder on the
power supply terminal board. Replace it with a new
fuse (5x20 -2 Amps - instantaneous type) by
exerting slight pressure until it enters the housing.
Replace the fuse cap in the terminal board.
8.3 GAS SOLENOID VALVES
Disconnect the electric connection on the gas
unit. Remove the two screws that attach the
metal support block of the coils and remove it
from the housing. Pull out the coil(s) from the unit
and replace them with new ones. Replace the
metal support block in the correct position and
tighten the fastening screws. Re-establish the
electrical connection
(fig. 25).
8.4 CONVECTION FAN CONTROL THERMOSTAT
Disconnect the cables and unscrew the
thermostat from the threaded support. Insert the
new thermostat, screwing it all the way in by
hand (do not use tools which might damage the
thermostat). Make sure that the distance between
the thermostat enclosure and the threaded
support is not greater than 3 mm, to guarantee
that the sensor remains in contact with the wall
of the exchanger. Re-establish the electrical
connection
(fig. 26).
8.5 SAFETY LIMIT THERMOSTAT
Disconnect the electric connection of the
thermostat on the appliance terminal board.
Release the thermostat by disassembling the
attachment plate on the air heater shield. Mount
the new thermostat by reversing the order of the
Fig. 24
CONTROL EQUIPMENT REPLACEMENT
Equipment enclosure
Connectors
and terminals for
electrical connections
Fig. 26
FAN THERMOSTAT REPLACEMENT
Thermostat
Exchanger
Threaded
support
Unscrew
Fig. 25
GAS UNIT COIL REPLACEMENT
Coil support
Gas unit
Fastening screws
Solenoid
valve coils
Valve rectifier
bridge
Содержание GHIBLI 4-5-6 ELITE
Страница 2: ......
Страница 11: ...page 9 1 11 EXPLODED VIEW Model Ghibli 4 Fig 5...
Страница 12: ...page 10 1 11 EXPLODED VIEW Models Ghibli 5 and 6 Fig 6...
Страница 30: ...page 28 NOTE...
Страница 31: ......