page 22

- Restore the connection or replace the

electrode including the cable. Do not make
joints to avoid reducing the cable insulation
level.

c)

The ignition electrode is not correctly
positioned or its ceramic insulation is
damaged, with a subsequent leakage of the
ignition discharge.

- Replace the electrode including the cable.

7.2.3  At the end of the pre-ventilation phase,
the ignition electrode discharges, but the
flame is not formed and the control equipment
locks out within the safety time.

a)

No gas supply or there is air inside the piping.

- Determine why there is no gas supply first

checking the on-off components on the feed
line. Completely bleed off any residual air and
restart the appliance.

b)

The gas solenoid valves do not open because
the coils are malfunctioning or their electrical
connection has been interrupted.

- Check if the connection cable and relative

terminals have been damaged. Use a special
tool to verify that the coils have failed and
replace them, if necessary (see point 8.3).

c)

The safety thermostat is malfunctioning and
does not allow the solenoid valves to open.

- Replace the safety thermostat (see point 8.5).

7.2.4  At the end of the pre-ventilation phase,
the ignition electrode discharges, the flame
is formed correctly, but the control equipment
locks out within the safety time.

a)

The phase-neutral electric power supply is
not correctly connected to the respective
terminals, marked as "L" and "N" and reversing
the polarity may de-activate the flame
detection device.

- Check using a multimeter or phase detector

and correctly connect the cables to the
corresponding terminals.

b)

The flame detection electrode is not correctly
positioned and is not in contact with the flame.

- Check if the electrode is properly connected

and if there are any deformations. Comply
with what is indicated in figure 28.

c)

The flame detection electrode electric
connection has been interrupted.

- Check the electrode connection to the control

equipment. If the cable or ceramic insulation
is damaged, replace the electrode in

accordance with the positions indicated in
figure 28.

d)

The flue gas exhaust fan motor is malfunctioning
or does not operate correctly because the
intake/exhaust duct is obstructed.

- First eliminate any obstructions in the terminal

and, if necessary, replace the fan, making
sure to re-assemble the unit as shown in fig.
29 (see point 8.8)

7.2.5  The control equipment locks out during
normal operation

a)

The gas supply was cut off and the equipment,
after repeating the ignition cycle, and without
detecting the flame within the safety time
period, entered the lock out mode.

- Determine why the gas supply prior to the air

heater was interrupted. Restart the appliance
using the Reset button on the control panel.

b)

The incorrect positioning of the external intake
and exhaust terminal has caused combustion
products to return and this prevents the flame
from being formed and therefore from being
detected by the electrode.

- Check that the terminal is not installed inside

niches or recesses in the walls and that there
are no obstructions that prevent the air from
circulating.

c)

The safety thermostat cuts off the supply to
the gas solenoid valve because overheating
has occurred due to incorrect operation or a
failure of the convection fan.

- Check for obstructions or dust deposits on

the fan and/or relative grille. Replace the
malfunctioning fan, if necessary (see point
8.8).

d)

The safety thermostat cuts off the supply to
the gas solenoid valve because overheating
has occurred due to incorrect operation of the
fan control thermostat.

- Replace the fan control thermostat (see point

8.4).

7.2.6 The burner stops while it is operating,
even if the room temperature does not
require it

a)

The room thermostat is defective.

- First check that the thermostat sensor is in

the correct position and that its operation has
not been affected by dust deposits. Otherwise,
replace the defective room thermostat.

Содержание GHIBLI 4-5-6 ELITE

Страница 1: ...Technical Information GHIBLI 4 5 6 ELITE Gas fired convective air heaters GHIBLI 4 5 6 ELITE Cod 25619502IT Rev 0 20 03 2013...

Страница 2: ......

Страница 3: ...l data styling characteristics components and accessories detailed in this manual are not binding A2B ACCORRONI E G S r l reserves the right to make changes at any time that are considered necessary t...

Страница 4: ...6 1 Switching from gas in the second group to gas in the third group 20 6 2 Switching from gas in the third group to gas in the second group 20 7 OPERATING DEFECTS 21 7 1 Preliminary tests 21 7 2 Pos...

Страница 5: ...stduct 16 16 Solution with duct doubling device 16 17 Location of the doubling device in the wall 16 18 Coupling with the doubling device 16 19 Power supply cable connection 18 20 Connecting more than...

Страница 6: ...aching the CE marking shown below also guarantees that the appliance conforms with EEC directive 2006 95 Lowvoltage throughtheharmonisedstandard EN 60335 1 and EEC directive 2004 108 Electromagnetic c...

Страница 7: ...e the gas unit the room thermostat and related wiring 1 5 PACKAGE CONTENTS Theairheaterisshippedwithcardboardpacking withtwopolystyrenefoamprotectionshellswhich also contain the intake and exhaust duc...

Страница 8: ...page 6 1 8 DIMENSIONI E INGOMBRI A B C Aspir Scar Gas Ghibli 4 717 267 534 65 G 3 8 Ghibli 5 6 807 366 624 65 G 3 8 Fig 1...

Страница 9: ...V 50 Hz 8 7 6 5 4 3 2 1 18 19 M3 Al T 1 9 WIRING DIAGRAM Ghibli Model 5 Fig 3 Al External auxiliaries supply Ac Control equipment Co Fan speed switch Ea Ignition electrode Er Flame detection electrode...

Страница 10: ...ater via a switch with contact opening of at least 3 mm Observe the correct phase neutralpolarity when connecting the single phase 230 V 50 Hz power supply 1 10 TECHNICAL DATA TABLE Units Ghibli 4 Ghi...

Страница 11: ...page 9 1 11 EXPLODED VIEW Model Ghibli 4 Fig 5...

Страница 12: ...page 10 1 11 EXPLODED VIEW Models Ghibli 5 and 6 Fig 6...

Страница 13: ...lite Components missing in the design 45610038 Bronze friction bearing 45960036 Kit of gas valve connection Legend of components Ghibli 5 and 6 see fig 6 Pos Code description 01 45660001 Casing Ghibli...

Страница 14: ...r The die cast aluminium casing is equipped with 3 8 RP threaded gas inlet and outlet connections and two inlet and outlet pressure test points The gas valve is also equipped with an inlet filter fig...

Страница 15: ...cted area 3 4 DATA CHECK Check that the heater and its technical characteristics match what is indicated by the drawings or other documents The type of gas for which the heater has been designed and t...

Страница 16: ...ons constitute the definition of type according to the current standards Type C12 standard supply The combustion circuit is hermetically sealed with respect to the environment in which the air heater...

Страница 17: ...t fig 14 4 4 INSTALLATION OPERATIONS Set up the gas and electricity supply lines based on the installation design 4 4 1 Air heater wall mounting preparations appliance with standard supply Installatio...

Страница 18: ...xhaust ducts Installation Type C52 Unlike the previous solution to mount the duct doubling device a recessed housing must be created in the wall and possibly some chases to indicate the duct layout fi...

Страница 19: ...used again b mount the aluminium flange 92 mm inserting the ring gasket and attaching it on the appliance fitting using the three screws supplied with the kit Check that the ring gasket fits correctly...

Страница 20: ...terminal board of the appliances after having removed the existing bridge 5 START UP WARNING The appliance initial start up operations and tests must be performed by skilled technical personnel 5 1 TE...

Страница 21: ...he safety thermostat Then repeat the start up operation to observe and check that the burner has ignited correctly and that the flame is stable 5 3 USEFUL INFORMATION It is recommended that the user b...

Страница 22: ...uge tube into the upstream pressure inlet on the burner fig 22 after having backed off the closing screw a few turns h start the air heater according to what is indicated in point 5 2 Check that the s...

Страница 23: ...external terminal of the combustion air intake and combustion product exhaust duct is not obstructed 7 2 POSSIBLE DEFECTS The following is a list of possible defects along with their probable causes T...

Страница 24: ...electrode electric connection has been interrupted Check the electrode connection to the control equipment If the cable or ceramic insulation is damaged replace the electrode in accordance with the po...

Страница 25: ...ch the metal support block of the coils and remove it from the housing Pull out the coil s from the unit and replace them with new ones Replace the metal support block in the correct position and tigh...

Страница 26: ...g the 6 screws that were previously removed 8 7 FLUE EXHAUST FAN Disconnect the motor electrical connection and loosen the three scroll fastening screws Gently remove the motor fan unit and respecting...

Страница 27: ...Replace the burner support plate making sure that the relative gasket is in the correct position Attach the plate using the 6 screws that were previously removed Check that the external intake exhaust...

Страница 28: ...ed led will turn off If the lockoutconditioncontinues thisgenerally means that there is a fault or an operating defect Therefore it is recommended to contact a Technical Service Centre The exchanger h...

Страница 29: ...heck that the external terminal of the intake exhaust duct is not obstructed or that the relative material has deteriorated b clean the external parts of the air heater simply by using a damp cloth an...

Страница 30: ...page 28 NOTE...

Страница 31: ......

Страница 32: ...A2B ACCORRONI E G S r l Via d Ancona 37 60027 Osimo An Tel 071 723991 Fax 071 7133153 Web Site www accorroni it E mail a2b accorroni it...

Отзывы: