background image

www.acclaimlighting.com

Unity™

User guide

Содержание Unity SNS2019

Страница 1: ...Unity User guide...

Страница 2: ......

Страница 3: ...1 21 Cabling with OLS 23 Wireless DMX control 25 CONFIGURATION 26 Removing the display cover 26 Entering the menu 26 Menu navigation 27 Setting the DMX address 29 Returning to factory settings 29 View...

Страница 4: ...43 Troubleshooting 43 Correlated color temperature selection 44 Optimizing signal strength via channel selection 45 Choosing the right location 46 Specifications 47 Dimensions 48 FCC approval 51 Limit...

Страница 5: ...alls below a certain level paired with a configurable timer for auto shut off The internal auto sensing power supply can accept mains inputs between 100 to 277VAC at 50 or 60Hz Each Unity fixture is s...

Страница 6: ...detachable 9 foot 2 7m combined power and control tail Optional Outdoor Linking System feed cables are directly compatible see page 7 Half snoots Gray UNAHSG Black UNAHSB White UNAHSW Custom UNAHSC Fu...

Страница 7: ...om TM2C TM4C Pipe clamps For use with Schedule 40 pipe 2 51 and 4 13 inner diameter respectively polished aluminum finish 2 pipe PC2 4 pipe PC4 Extender arms Fixture bolts and washers plus cable acces...

Страница 8: ...NPS1 24G UNANPS1 36G Black UNANPS1 12B UNANPS1 24B UNANPS1 36B White UNANPS1 12W UNANPS1 24W UNANPS1 36W Custom UNANPS1 12C UNANPS1 24C UNANPS1 36C RAL also required Aircraft cable mount set Includes...

Страница 9: ...page 21 AJBOX1 OUTDOOR LINKING SYSTEM PART CODES Feed cables 1 30cm OLSF1 5 1 5m OLSF5 10 3m OLSF10 25 7 6m OLSF25 50 15 2m OLSF50 T junction OLST Terminator OLSEC Link cables 1 30cm OLSL1 5 1 5m OLS...

Страница 10: ...rench to focus the fixture Loosen the pivot bolt on each side and gently pull apart the yoke arms to allow the fixture body to rotate Release the yoke arms and tighten the bolts when the required tilt...

Страница 11: ...re below a pole For pendant type installations use the pendant mount set see page 12 TO USE A TENON MOUNT 1 Slide the tenon mount onto the vertical pole and tighten the two bolts on the side using a 1...

Страница 12: ...w about the correct use of the supplied washers 4 Tighten the two main bolts evenly until the clamp is held firmly in place 5 Use the two smaller bolts with spring and standard washers to fix the Unit...

Страница 13: ...l screws are not provided ensure the ones used are suitable for the wall surface and have sufficient tensile strength for the combined weight and leverage of the fixture plus the bar CONCEALED CABLING...

Страница 14: ...each side of the yoke Gently pull the arms of the yoke out from the fixture body so that the pivot points disengage thus freeing the yoke from the fixture body 2 Transfer the two pivot cups from the...

Страница 15: ...ttach the top bracket Note When the NPS pipe is fitted to the top bracket and correctly secured with the two locking bolts the pendant yoke will always become aligned with the axis of the top bracket...

Страница 16: ...align with these holes and the bolts are fully engaged Plug the power control cord into the socket on the rear panel of the Unity fixture If necessary tilt the fixture to the required angle by loosen...

Страница 17: ...e Unity fixture face down on the surface Use a 5 16 8mm Allen hex wrench to remove the large pivot bolt from each side of the yoke Gently pull the arms of the yoke out from the fixture body so that th...

Страница 18: ...vots of the fixture Insert the large pivot bolts on each side of the yoke and use a 5 16 8mm Allen hex wrench to tighten them 4 Attach the top bracket securely to the ceiling Use two fixings appropria...

Страница 19: ...et and into the ceiling space Raise up the cover plate and align it with the two small holes in the underside of the top bracket Insert the two small bolts removed earlier and tighten Plug the power c...

Страница 20: ...tically upwards 1 Use a 1 8 3mm Allen hex wrench to remove the four bolts that secure the front ring and remove the ring 2 Remove the front ring and place the snoot onto the front of the fixture The s...

Страница 21: ...xtures are low power devices compared to their incandescent equivalents their power supplies exhibit a trait known as in rush current when they are first powered on This is caused by the various compo...

Страница 22: ...of 1 500 ft 457m without buffering Do not exceed a total of 32 fixtures on a single line without buffering Use only connection cables with a characteristic impedance of 120 preferably where the DMX a...

Страница 23: ...t preparing cables for use within the AJBOX1 AC power input NPT thread Combined feed output NPT thread DMX input NPT thread HV LV barrier Surge protector IP66 lid Shown here with cable gland inputs ra...

Страница 24: ...nd white black striped are not used and can be trimmed We suggest that you cut them short at slightly different lengths and ensure that no conductors are visible Optionally you could also cap them off...

Страница 25: ...outputs have connectors with black collars The blue and black connectors mate quickly and easily with a twist of the collar to lock them securely in place A typical configuration is shown on the next...

Страница 26: ...C 5 x Unity 150 230VAC 10 x Unity 300 277VAC 12 x Unity 350 See also page 23 A terminator must be fitted to the final T junction to simultaneously protect the live connections and correctly terminate...

Страница 27: ...it will automatically output the full received DMX universe on its output wires This means that you can wire through and control up to 32 non Aria DMX fixtures such as Pixel Graze or more if an activ...

Страница 28: ...iod a locked symbol will be shown and you will need to once again press and hold the MENU button for roughly 7 seconds to unlock it SEE ALSO Menu navigation on page 27 Main menu items on page 28 Opera...

Страница 29: ...nd the menu and alter settings as necessary The next page lists the main menu items 7 second press to initially enter the menu Use the arrow buttons to move between main menu items Use the arrow butto...

Страница 30: ...ickering on video images See page 33 Allows various changes to the user display such as invert backlight timeout temperature units etc See page 34 Allows you to create a static color mix that will be...

Страница 31: ...ee page 26 2 Use the or buttons to locate the Factory Setting option and press ENTER The display will show Reset to Factory Defaults 3 Press ENTER The display will show Are you sure 4 Use the button t...

Страница 32: ...channel modes to determine how received DMX input values are mapped to the various emitter colors Note The channel mode can also be configured via RDM see page 38 7 CHANNEL Allows you to control the f...

Страница 33: ...ETTING AN INTERNAL COLOR This option allows you to mix a static color or selected white which will be displayed whenever the following two criteria are met The Solo Behavior option is set to Internal...

Страница 34: ...ivity and press ENTER The display will show the ambient light level at which the fixture should begin outputting 100 is the most sensitive to light Some experimentation will be required to determine t...

Страница 35: ...26 2 Use the or buttons to locate the Gamma option and press ENTER The current Gamma setting will be shown 3 Press ENTER and then use the or buttons to show the required gamma setting 4 Press ENTER to...

Страница 36: ...ture is exceeded If the over temperature condition persists for more than 10 minutes the fixture will shut itself down Temperature Unit allows you to change between o F and o C when displaying reading...

Страница 37: ...f white For example a balanced warm white derived from a significant red output with a moderate green output while the other colors are scaled back To achieve identical white balance across a collecti...

Страница 38: ...via RDM over a wired DMX link the Aria wireless link itself does not support RDM which requires 2 way communication The Aria wireless radio channel setting is completely independent of the DMX addres...

Страница 39: ...GURE THE DMX ADDRESS USING THE XMT 350 1 Connect the XMT 350 to the DMX input line of the Unity installation 2 On the XMT 350 press the MODE button then use the arrow buttons to highlight the RDM func...

Страница 40: ...RDM devices and after a short while the XMT 350 will display a list of all located fixtures The fixture highlighted in the list should show output from its emitters to identify itself 3 If necessary...

Страница 41: ...hould show output from its emitters to identify itself 3 If necessary use the up down buttons to highlight an alternative fixture 4 Press the button to view details for the chosen fixture and then use...

Страница 42: ...the button to select The XMT 350 will search for RDM devices and after a short while the XMT 350 will display a list of all located fixtures The fixture highlighted in the list should show output fro...

Страница 43: ...to highlight an alternative fixture 4 Press the button to view details for the chosen fixture and then use the down button to highlight the MODEL entry 5 Press the button to view the options 6 Use the...

Страница 44: ...lation 2 Power on the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use the arrow buttons to highlight the SEND function and press the button to select SEND DMX ADDRESS LEVEL 0...

Страница 45: ...page 32 if it is enabled and the ambient light level is higher than the programmed sensitivity setting this will prevent the mixed color white from being shown If Aria wireless DMX control is being u...

Страница 46: ...EMPERATURE SELECTION This chart lists the DMX values which must be presented to channel 6 in order to achieve an output with a particular correlated color temperature CCT of white DMX input value Colo...

Страница 47: ...13 2 12 14 1 11 0 10 9 8 5 6 7 5MHz 3MHz 11 2462 Aria radio channels WiFi 2 4 GHz 2 5 GHz 2 4 GHz 2 5 GHz 2 2417 1 2412 WiFi IEEE802 11 channels Channel Mid frequency 3 2422 4 2427 5 2432 6 2437 22MH...

Страница 48: ...RF signal Here are a few examples Standard drywall does not present much of an issue to the 2 4GHz wireless spectrum However things inside or attached to the drywall such as copper pipe electrical con...

Страница 49: ...perating voltage 100 277VAC 50 60Hz Power consumption 330W Connection 9 2 7m NEC compliant hybrid cable with bare tails attached via composite connector IP66 AC power plus DMX RDM Finish Gray standard...

Страница 50: ...48 DIMENSIONS...

Страница 51: ...49 DIMENSIONS CONTINUED PENDANT MOUNT SET AIRCRAFT CABLE MOUNT SET TOP BRACKET BOTH MOUNT TYPES...

Страница 52: ...50 DIMENSIONS CONTINUED EXTENDER ARMS SNOOTS Half snoot Full snoot...

Страница 53: ...not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment If this equipment does cause harmful interference to radio or television recepti...

Страница 54: ...ms not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and repair labo...

Страница 55: ......

Страница 56: ...www acclaimlighting com...

Отзывы: