background image

13

www.acclaimlighting.com

Testing emitter output

After you have addressed each Dyna Graze HO Exterior DMX fixture we recommend that 
you also test each one prior to installation. This can be achieved with your RDM (Remote 
Device Management) tool. Various third party DMX/RDM tools are available; Acclaim 
Lighting particularly recommend the Swisson XMT-350 for this task.

To test emitter output using the Swisson XMT-350

1  Connect the XMT-350 to the DMX input line of either a single fixture or multiple fixtures in 

a pre-arranged daisy chain configuration.

2  Power on the fixture(s) and the XMT-350.
3  On the XMT-350, press the 

MODE

 button, then use the arrow buttons to highlight the 

SEND

 function and press the   button to select. 

4  Use the arrow buttons to determine the DMX output:

 

Use the left and right buttons to choose the DMX address,

 

Use the up and down buttons to increase/decrease the level at the chosen address. 

Note: If you wish to send DMX values to all addresses simultaneously (rather than cycling 
through them individually), when the XMT-350 is showing address 001, press the left button 
once to change to 

ALL CHANNELS

. Now when you set the level it will affect all emitters equally.

  

Содержание Dyna Graze HO Exterior DMX

Страница 1: ...Dyna Graze HO Exterior DMX User guide...

Страница 2: ......

Страница 3: ...ustment 4 Optional 90O bracket 5 Fitting the glare shield 6 Fitting an optional louver 7 Power and control wiring 8 DMX channel designations 10 Operation 11 Addressing fixtures 11 DMX personality mode...

Страница 4: ...te emitters Additionally to ensure the correct fit with your installation you have four lens options 10 x 10 10 x 60 30 x 60 or 60 x 60 External control is achieved using the industry standard DMX 512...

Страница 5: ...hield and two small locking screws Feed cable plus end cap 10 3m DGHFC10 Link cables 1 30cm DGHLC1 5 1 5m DGHLC5 10 3m DGHLC10 End cap DGHEC Louvers 12 30cm DGHLV12 48 1 5m DGHLV48 Extender bars 6 15c...

Страница 6: ...and are particularly suited to the mounting surface Mount adjustment The standard mount s provided with each Dyna Graze fixture 1 models have one mount 4 models have two allow tilt angles of roughly 3...

Страница 7: ...irection To achieve tilt angles up to 90 degrees you will need to replace the standard brackets with optional 90O brackets Standard mount bracket 0 to 30 degree angles possible Optional 90O mount brac...

Страница 8: ...e two channels located on either side of the emitter housing Note You may find that the glare shield is tight and difficult to slide in particularly on the 4 models If so smear a small quantity of pet...

Страница 9: ...er housing Note You may find that the louver is tight and difficult to slide in particularly on the 4 models If so smear a small quantity of petroleum jelly onto the angled lips of the louver to help...

Страница 10: ...lor designations for the optional feed in cable are as follows Power The power requirements are as follows Voltage 100 277VAC 50 60Hz Power 20W per 1 section 80W for a 4 model Control The control link...

Страница 11: ...e in rush current values for the Dyna Graze HO Exterior DMX fixtures are as follows Dyna Graze HO Exterior DMX 1 30A max full load Dyna Graze HO Exterior DMX 4 40A max full load Maximum number of fixt...

Страница 12: ...r DMX channel designations The various Dyna Graze HO Exterior DMX variants apply their LED emitters to DMX channels in different ways as summarized in the table below The 1 models always operate in St...

Страница 13: ...ttons to highlight the RDM function and press the button to select The XMT 350 will search for RDM devices and after a short while the XMT 350 will display a list of all located fixtures The fixture t...

Страница 14: ...the DMX input line of either a single fixture or multiple fixtures in a pre arranged daisy chain configuration 2 Power on the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use...

Страница 15: ...ultiple fixtures in a pre arranged daisy chain configuration 2 Power on the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use the arrow buttons to highlight the SEND function a...

Страница 16: ...no damage to the power input cord Use an RDM tool such as the Swisson XMT 350 to check the settings and internal temperature of the fixture Using an RDM tool check that the DMX address set within the...

Страница 17: ...4 lengths Ingress protection IP66 wet location Fixture connectors FINEcables M20 3 5P IP67 combined power and control Maximum lengths in series 50 15m 120VAC or 100 30m 240 277VAC Power input 100 277...

Страница 18: ...lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in mate...

Страница 19: ......

Страница 20: ...www acclaimlighting com...

Отзывы: