background image

 

80 Bays SAS to SAS/SATA JBOD Subsystem 

 

20 

User Manual 

 

2.5   Expander Module 

 

The 80bay JBOD subsystem contains 

Master 

and

 Slave Expander Modules

. The 

Expander Module contains the SAS expander. It can be used to upgrade the SAS 
expander firmware. It also contains the SES module (SCSI Enclosure Services).  
SES is the protocol used for enclosure environmental control. 
 
The 

master

 expander module monitors the following enclosure conditions: 

temperature, power supply voltage, and fan speed.  
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

 

 
 
 

The slave expander module monitors the temperature and power supply voltage 
conditions. (Only for dual JBOD controller) 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание JetStor SAS 780JH JBOD Subsystem

Страница 1: ...JetStor SAS 780JH JetStor SAS 780JHD JBOD Subsystem User Manual Revision 1 4...

Страница 2: ...2 Rear View 14 2 2 JBOD Controller Module 15 2 3 Power Supply Fan Module PSFM 16 2 4 Fan Module 18 2 4 1 FAN Panel 19 2 5 Expander Module 20 2 6 Disk Drive Installation into the Disk Slot 21 2 6 2 To...

Страница 3: ...placing JBOD Subsystem Components 49 4 2 1 Replacing JBOD Controller Module 49 4 2 2 Replacing Power Supply Fan Module 50 Appendix A Zoning Configurations 51 A 1 Zoning mode 0 Default No Zoning 51 A 2...

Страница 4: ...this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent T...

Страница 5: ...he installation site temperature making it not to exceed the allowed ambient temperature Before plugging in any power cords cables and connectors make sure that the power switches are turned off Disco...

Страница 6: ...d contact the dealer or vendor for assistance JBOD Subsystem Unit 80 pairs of HDD side brackets Four 4 Power cords One 1 external SAS cable for single JBOD controller Note Two SAS cables for dual JBOD...

Страница 7: ...ance index with higher bandwidth Features 80 hot swappable drive bays in a rackmount 4U chassis Simultaneously support SAS2 or SATA3 disk Single or dual SAS2 JBOD controller module Each SAS2 JBOD cont...

Страница 8: ...to RAID controller specification Monitor Port support Yes Enclosure Platform Rackmount Form Factor 4U of Hot Swap Trays 80 Disk Status Indicator Access Fail LED Backplane SAS2 SATA3 of PS Fan Modules...

Страница 9: ...MPORTANT When powering off the JBOD subsystem turn off first the Main Switch last for more than 4 seconds and allow at least 4 minutes for the subsystem to shutdown properly Then turn off the switches...

Страница 10: ...his is also used to move between each menu Select button This is used to enter the option you have selected Exit button EXIT Press this button to return to the previous menu NOTE This button can also...

Страница 11: ...LED If system backplane temperature is over 85o C or BP and disk temperatures exceed 55o C the Over Temperature LED will turn RED and alarm will sound Voltage Warning LED An alarm will sound if detec...

Страница 12: ...N01 3970rpm Good FAN12 3970 RPM Voltage Status Good Status Disabled Disable Buzzer Enable Buzzer power 1 Good power 2 Good power 3 Good power 4 Good BP 5V 4 94V BP 3 3V 3 2V BP 12V 12 48V JBOD BP 5V 4...

Страница 13: ...tus Indicator Color Description Activity LED Blue Blinking Indicates the disk drive is busy or being accessed Power On Fail LED Green Indicates the disk drive in this slot is good RED Indicates the di...

Страница 14: ...80 Bays SAS to SAS SATA JBOD Subsystem 14 User Manual 2 1 2 Rear View Single Controller Dual Controller...

Страница 15: ...on Chassis If LED is off the Expansion Chassis is in normal condition RS 232 Port Used for upgrading the Firmware of JBOD controller in the Expansion Chassis Mute Use this button to silence the alarm...

Страница 16: ...Supply Fan Module PSFM The 80bay JBOD subsystem contains four 650W Power Supply Fan Modules All PSFM are inserted at the rear of the chassis NOTE Each PSFM delivers Full Range 100V 240V 10 voltage AC...

Страница 17: ...en Indicates the power supply module is good Red Indicates the power supply module is faulty Fan Fail LED Red Indicates fan in the PSFM has failed When the power cord connected from main power source...

Страница 18: ...80 Bays SAS to SAS SATA JBOD Subsystem 18 User Manual 2 4 Fan Module The 80bay JBOD subsystem contains 12 fans...

Страница 19: ...80 Bays SAS to SAS SATA JBOD Subsystem User Manual 19 2 4 1 FAN Panel Indicator Color Description Fan Fail LED No light Indicates the fan is normal Red Indicates the turbo fail is faulty...

Страница 20: ...e used to upgrade the SAS expander firmware It also contains the SES module SCSI Enclosure Services SES is the protocol used for enclosure environmental control The master expander module monitors the...

Страница 21: ...0 disk drives for quicker and easier installation of disk drives in the Disk Array it is recommended to attach first each disk drive with HDD side brackets and paste the slot number labels DISK SLOT N...

Страница 22: ...n a disk tray is done differently In single controller mode the installation of SATA disk in a disk tray is the same with SAS disk HDD Single Controller Dual Controller SATA No need dongle board Need...

Страница 23: ...23 2 6 2 To install a SAS disk drive Single or Dual Controller Mode or SATA disk drive Single Controller Mode in a disk tray 1 Prepare the HDD side brackets Remove them from the dummy disk by pushing...

Страница 24: ...AS SATA JBOD Subsystem 24 User Manual 2 Place the brackets on both sides of the disk drive and secure them with screws 2 screws 6 32 UNC L 5 0mm 3 Place the drive carefully in the disk slot 3 screws 6...

Страница 25: ...80 Bays SAS to SAS SATA JBOD Subsystem User Manual 25 4 Tighten the thumbscrews on the sides of the disk drive...

Страница 26: ...Manual 5 Repeat the same steps for the rest of the disks Note The slot Number labels are included in the package It is recommended to paste these labels on the hard disks to identify drives Slot Numbe...

Страница 27: ...11 16 21 26 31 36 41 46 51 56 61 66 71 76 you need to release the subsystem from the rail by pushing white locks on both sides of the inner rail members at the same time View from Right Side of Enclo...

Страница 28: ...80 Bays SAS to SAS SATA JBOD Subsystem 28 User Manual 6 Close the top cover by pressing the black locks...

Страница 29: ...80 Bays SAS to SAS SATA JBOD Subsystem User Manual 29 7 Then push the enclosure inwards or backwards until it goes inside the rack...

Страница 30: ...priate sections on how to remove the power supply modules and how to remove the disk trays disk drives NOTE The sample model used in the following installation might not be the actual model for this m...

Страница 31: ...left side of the rack post Rack Post Front Left Side 4 Insert three 3 M5 nuts on the 3 holes of the front right side of the rack post Rack Post Front Right Side Position of M5 nuts on the 3 holes of l...

Страница 32: ...les on the rear rack post and then push the rail a little towards the rear side and lock the lock lever on the rack post View from Rear Side of Rear Left Rack Post Lock Lever Lock Lever Latches View f...

Страница 33: ...the Lock Lever to lock the rail assembly in the left rack post View from Rear Side of Front Left Rack Post 2 Latches are inserted in the 4th and 6th holes from bottom M5 nut View from Front Side of Fr...

Страница 34: ...ht side View from Rear Side of Rear Right Rack Post 9 Repeat step 7 to install the other rail assembly into the right front side Lock Lever Latches Lower M5 nut Lock Lever View from Front Side of Fron...

Страница 35: ...ght Rack Post 2 Latches are inserted in the 4th and 6th holes from bottom M5 nut 10 Pull the 2 middle rail members out from the rail assembly Middle Rail Member of Rail Assembly on Right Side of Rack...

Страница 36: ...stops or about half way through NOTE Be careful when inserting the 2 inner rails into the middle rails The 2 inner rails must be parallel with the 2 middle rails so that 2 inner rails will insert and...

Страница 37: ...inserting the enclosure in the rail Keep holding the enclosure moved inside the rack When the half rear side is inside the rack you can put down the two rear handles but support in the bottom part of...

Страница 38: ...r rail members at the same time Then push the enclosure inwards or backwards until it goes inside the rack View from Right Side of Enclosure Blue Lock of Inner Rail is Pushed a Little Outwards and Enc...

Страница 39: ...six 6 M5 screws to lock the enclosure into the rack post one screw in each corner Note that the screwdriver will need to pass through the corner hole of front panel for the two upper corner holes on b...

Страница 40: ...em 40 User Manual 14 Insert the power supply modules 15 Open the top cover and re insert the disk drives disk trays if disk drives disk trays were previously removed Please refer to Section 2 6 Disk D...

Страница 41: ...SAS to SAS SATA JBOD Subsystem User Manual 41 3 2 Removing the Disk Array from the Rack 1 Remove the power supplies in the rear 2 Remove the four screws in the front corner Front Left Side Front Righ...

Страница 42: ...slots Note When removing the first column disks Slot 1 6 11 16 21 26 31 36 41 46 51 56 61 66 71 76 you need to release the subsystem from the rail by pushing white locks on both sides of the inner rai...

Страница 43: ...er Manual 43 5 Remove the two screws in the front corner Note that the screwdriver will need to pass through the corner hole of front panel for the two upper corner holes on both sides 6 Release the s...

Страница 44: ...of SAS cable to the SAS In Port of the JBOD subsystem enclosure and the other end to the SAS HBA on the Host system 3 5 Powering On 1 Plug in all the power cords into the AC Power Input Socket locate...

Страница 45: ...6 Powering Off IMPORTANT When powering off the JBOD subsystem turn off first the Main Switch last for more than 4 seconds and allow at least 4 minutes for the subsystem to shutdown properly When JBOD...

Страница 46: ...array setting on the JBOD disks The new Firmware will effective after JBOD power cycle NOTE Upgrading the firmware must be done from Master JBOD Controller JBOD Controller 1 if the JBOD Subsystem has...

Страница 47: ...S to SAS SATA JBOD Subsystem User Manual 47 2 Select Transfer Send File Select your firmware file path and select Xmodem in the communication protocol and click transfer button You must finish within...

Страница 48: ...80 Bays SAS to SAS SATA JBOD Subsystem 48 User Manual 3 Wait for the transfer of file to complete 4 When the transfer and firmware update is complete please power cycle the JBOD...

Страница 49: ...the JBOD Controller Module drawer 2 Use the Controller handle to pull out the defective JBOD Controller Module drawer 3 Insert and slide the new JBOD Controller Module in Note that it may be necessar...

Страница 50: ...thumbscrews of the PSFM 4 Use the handle to pull out the defective PSFM 5 Before inserting the new PSFM make sure the Power On Off Switch is on Off state 6 Insert and slide the new PSFM in until it cl...

Страница 51: ...y overheating when the Fans cannot work Appendix A Zoning Configurations The JBOD subsystem features provide for zoning on the JBOD Controller Modules This allows the input ports on the JBOD Controlle...

Страница 52: ...d 4 on both JBOD Controller Modules Drive Group 2 Drive Group 1 61 41 21 1 62 42 22 2 63 43 23 3 64 44 24 4 65 45 25 5 66 46 26 6 67 47 27 7 68 48 28 8 69 49 29 9 70 50 30 10 71 51 31 11 72 52 32 12 7...

Страница 53: ...e Group 1 are reported If the drives are accessed through subsystem JBOD Controller Module 2 then the drives present in Drive Group 2 are reported Drive Group 2 Drive Group 1 61 41 21 1 62 42 22 2 63...

Страница 54: ...hrough subsystem Host Port 3 on either JBOD Controller Module then the drives present in Drive Group 3 are reported If the drives are accessed through subsystem Host Port 4 on either JBOD Controller M...

Отзывы: