background image

1. Switch into automatic dosing mode by long pressing 

Power

 and selecting the Auto mode with the 

Dial

. Press 

Power

 again to confirm the mode.

2. Select or adjust a preset weight.

3. Press 

Dose

 to start automatic dosing, the display will show [ 

rEADY 

]. 

4. To start the first dose, press 

Dose

 again and the automatic dosing will begin.

5. Remove the completed dose, and wait for the display to show [ 

rEADY

 ] again.

6. Place another container on top of the platform and dispensing will start again.
7. Press 

Power

 to set a different dose and leave the current auto dosing session. 

•  Auto dosing mode can dose automatically whenever a container is placed on the platform.

•  There will be an ‘A’ indicator on the top left corner of the display when in Auto mode.

•  A [

 NO ISE

 ] message will show when a container is removed from the Orion Mini or the platform is 

touched during dosing. Please dose again.
Pulse in Auto dosing mode

The pulse function also works in the auto dosing mode. To pulse (or add) a few more beans at the end 

of each dose, simply press the 

Dose

 button and the Orion Mini will add a small amount of beans with 

each press. If one press does not dispense any beans, you can press it multiple times until the desired 

weight is reached.

Auto dosing mode can dose automatically whenever a container is placed on the platform. There 

will be an ‘A’ indicator on the top left corner of the display when in Auto mode.

At the end of auto dosing, you may short press the 

Dose

 button to ‘pulse’ a few more coffee 

beans if required. A [ 

rEADY

 ] message will show on the display when auto dosing mode is in 

action. To leave the [ 

rEADY

 ] display, short press the 

Power

 button. You will be able to return to 

the preset selection display.

Mode 2 - Auto Dosing Mode

8

Action

Operation

Enter Ready State

Short press

 Dose

Start Dosing

Short press

 Dose

Stop Dosing

Short press

 Dose

Pulse Beans 

Short press

 Dose

Reset Mode

Short press

 Power

Display

Description

rEADY

Place container on the platform; dosing will start when weight is 

detected

Содержание Orion Mini Bean Doser

Страница 1: ...Acaia Orion Mini User Manual V 3 00 01...

Страница 2: ...tions Basic Operations Set Preset Weight Switch Mode Empty Hopper Mode Introduction Mode 1 Manual Dosing Mode Mode 2 Auto Dosing Mode Mode 3 Weighing Mode Settings Accessing the Orion s Settings Diagr...

Страница 3: ...allowing easy access by rotating the dial for different functions Weighing Scale Mode The Orion Mini Bean Doser can function as a smart industrial weighing scale with a capacity of up to 3000 grams St...

Страница 4: ...display shows CUP rESEt please place a container on the platform 5 When a dose is complete press Power to return to dosing The Orion Mini is designed for dosing portions of beans from 5 grams to a max...

Страница 5: ...rion Mini is in Weighing Mode and the weighing unit is in grams rapidly press the Dose button multiple times until the LED display shows CAL and then 500 2 Place a 500 gram calibration weight on the p...

Страница 6: ...2 at 20 g and preset 3 at 35 g You may adjust the preset value with the controls above There are 2 different modes in the Orion Mini for operation Manual dosing mode and Auto dosing mode You may set...

Страница 7: ...press Dose several times to pulse Pulse will slowly add a few more beans if needed 4 Press Power to start a new dose Manual dosing mode can dose on demand with a selected preset A NOISE message will s...

Страница 8: ...e The pulse function also works in the auto dosing mode To pulse or add a few more beans at the end of each dose simply press the Dose button and the Orion Mini will add a small amount of beans with e...

Страница 9: ...To switch to weighing mode rotate the Dial until a W indicator appears on the top left corner of the display The weight of the object on the platform will be shown on the display The Power and Dose bu...

Страница 10: ...d Key Sound bEEP On Off On Default Weighing Unit Unit g oZ g Calibration CAL Start calibration About About Show the current Orion Mini Firmware version 1 With Orion Mini powered on long press Power to...

Страница 11: ...ple since each division is 0 1 g 3 d 0 3 g When Zero Tracking is set to be 3 d any initial weight between 0 3 g on the weighing pan will be zeroed out 3 2 d is recommended in general for the Orion Min...

Страница 12: ...Function Example Power Button Turn On Short press to turn on the Orion Mini Turn Off Double press to turn off the Orion Mini Set Save Preset Weight Short press to set save preset weight Set Modes Lon...

Страница 13: ...er the minimum capacity Error 304 Please calibrate the Doser in a stable environment free of vibration wind etc Error 802 Unable to tare because the weight exceeds the tare range Error 803 Unable to t...

Страница 14: ...Linearity 1 d 2 d 4 d d 0 1 g Indication Limit 3090 g 108 99 oz Power Supply 12 Vdc 1 5 A Battery Lithium ion rechargeable 7 4 V 2600 mAh Battery Life Up to 48 hours Display LED Material Aluminum Acry...

Страница 15: ...rights reserved No part of the manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other meth od in particular electronic means witho...

Отзывы: