background image

Green Light - Dosing progress indicator

When the green light is blinking, dosing is in progress. Once dosing is complete, the indicator will 

display a solid green light.

Yellow Light - Dose warning indicator 

When the yellow light is lit, it means that the current dose is at least 0.5 grams less or more than the 

target amount. You may want to add some beans with the pulse function or remove some.

Red Light - System message indicator

When the red light is displayed, there is a system error with the Orion Mini. Restart the Orion Mini. If 

the problem persists, please contact us at [email protected].

LED Indicators

Buttons

Button

Function

Example

Power

Button

Turn On

Short press to turn on the Orion Mini

Turn Off

Double press to turn off the Orion Mini

Set/Save Preset Weight

Short press to set/save preset weight

Set Modes

Long press to switch to Manual/Auto Mode

Save the Setting and 

Return to Menu

Short press to save the Setting and go back to 

Menu

Dose

Button

Start Dosing

Short press to start dosing when in Manual/Auto 

mode

Empty Hopper

Long press for 5 seconds to empty the hopper

Stop Emptying Hopper 

Short press to stop emptying the hopper

Save the Setting and 

Return to Menu

Short press to save the Setting and go back to 

Menu

Rotate Dial

Toggle Presets/Modes

Rotate to toggle presets/modes

Adjust Preset Weights

Rotate to adjust the preset weights

* Please go to 

Page 6: Operations

 for more details.

Appendix

12

Rotate

LED Indicator

Содержание Orion Mini Bean Doser

Страница 1: ...Acaia Orion Mini User Manual V 3 00 01...

Страница 2: ...tions Basic Operations Set Preset Weight Switch Mode Empty Hopper Mode Introduction Mode 1 Manual Dosing Mode Mode 2 Auto Dosing Mode Mode 3 Weighing Mode Settings Accessing the Orion s Settings Diagr...

Страница 3: ...allowing easy access by rotating the dial for different functions Weighing Scale Mode The Orion Mini Bean Doser can function as a smart industrial weighing scale with a capacity of up to 3000 grams St...

Страница 4: ...display shows CUP rESEt please place a container on the platform 5 When a dose is complete press Power to return to dosing The Orion Mini is designed for dosing portions of beans from 5 grams to a max...

Страница 5: ...rion Mini is in Weighing Mode and the weighing unit is in grams rapidly press the Dose button multiple times until the LED display shows CAL and then 500 2 Place a 500 gram calibration weight on the p...

Страница 6: ...2 at 20 g and preset 3 at 35 g You may adjust the preset value with the controls above There are 2 different modes in the Orion Mini for operation Manual dosing mode and Auto dosing mode You may set...

Страница 7: ...press Dose several times to pulse Pulse will slowly add a few more beans if needed 4 Press Power to start a new dose Manual dosing mode can dose on demand with a selected preset A NOISE message will s...

Страница 8: ...e The pulse function also works in the auto dosing mode To pulse or add a few more beans at the end of each dose simply press the Dose button and the Orion Mini will add a small amount of beans with e...

Страница 9: ...To switch to weighing mode rotate the Dial until a W indicator appears on the top left corner of the display The weight of the object on the platform will be shown on the display The Power and Dose bu...

Страница 10: ...d Key Sound bEEP On Off On Default Weighing Unit Unit g oZ g Calibration CAL Start calibration About About Show the current Orion Mini Firmware version 1 With Orion Mini powered on long press Power to...

Страница 11: ...ple since each division is 0 1 g 3 d 0 3 g When Zero Tracking is set to be 3 d any initial weight between 0 3 g on the weighing pan will be zeroed out 3 2 d is recommended in general for the Orion Min...

Страница 12: ...Function Example Power Button Turn On Short press to turn on the Orion Mini Turn Off Double press to turn off the Orion Mini Set Save Preset Weight Short press to set save preset weight Set Modes Lon...

Страница 13: ...er the minimum capacity Error 304 Please calibrate the Doser in a stable environment free of vibration wind etc Error 802 Unable to tare because the weight exceeds the tare range Error 803 Unable to t...

Страница 14: ...Linearity 1 d 2 d 4 d d 0 1 g Indication Limit 3090 g 108 99 oz Power Supply 12 Vdc 1 5 A Battery Lithium ion rechargeable 7 4 V 2600 mAh Battery Life Up to 48 hours Display LED Material Aluminum Acry...

Страница 15: ...rights reserved No part of the manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other meth od in particular electronic means witho...

Отзывы: