(b) Place fueling control panel power switch in off position. 
(c) Place manual fill switch in auto position. 

(24) Place defueling shutoff valve control lever to closed position; safety lever with 

lockwire. 

(25) Place fueling control panel power switch in off position. 
(26) Close access doors. 
(27) Disconnect fueling unit/airplane ground cable. 

NOTE: Steps (28) and (29) should be performed on condition or at operators 

discretion. 

(28) Depress valve stem in fuel line shroud drain valve, located aft of right main gear 

wheel well, to check for presence of fuel. Presence of fuel can indicate a ruptured 
line(s) or loose connection(s). 

(29) Drain forward auxiliary fuel tank cavity drain by depressing square valve stem in 

valve located on lower right side of fuselage below auxiliary tank. Presence of fuel 
at this drain indicates leak in auxiliary tank fuel cell and leak source must be 
determined. 

(30) Drain water from fuel tank sumps as follows: 

NOTE: All fuel tank sump drain valves operate identically. 

(a) Insert probe. of drain tool in center recess of sump drain valve, and apply 

upward force. 

NOTE: Fuel should flow immediately after upward force is applied to tool. 

The sump tool permits a fluid flow rate in excess of 3 gallons per 
minute creating the siphoning action necessary to remove a maximum 
amount of free water from the tank sumps and thus reduces corrosion 
and sumping time. 

(b) Drain tank sump until water ceases to flow. 

NOTE: Fuel tank sumps should be drained after sufficient time 

(approximately 45 minutes). for water to settle out of fuel. Sump 
draining directly after landing may not be effective as water may be in 
the form of ice and will not drain. 

Depending on duration of airplane Turn Around time, tank sumping 
may be more effective if accomplished immediately preceding 
refueling operation. 

(c) Check all sump drain valves for leakage; no leakage is permissible. 

ABX Air Inc. 
Printed: 8/27/2010 at 12:10:53 
PM 
REV 11 2008/12/11

DC-9 

MAINTENANCE MANUAL

 

EFFECTIVITY: 900-905, 909, 928, 930, 934, 939, 
953-960, 962-964, 980-984, 986 

12-12-00-3

CONFIG 00

Page 6

1999/11/15

This page must not be retained for reference

Содержание DC-9

Страница 1: ...upply Systems Los Altos Calif To drain sump B Sump drain tool 4298 1 Roylyn Inc Glendale Calif To drain sump C Drain bottle assembly 700200 1 Accessory Products Co Whittier Calif To drain sump 3 Gravity Fueling WARNING DO NOT OPERATE RADIO RADAR OR ANY OTHER ELECTRICAL ELECTRONIC EQUIPMENT ON AIRPLANE EXCEPT AS SPECIFIED RADAR AND HIGH FREQUENCY EQUIPMENT OPERATING IN VICINITY OF AIRPLANE DURING F...

Страница 2: ...TE If external electrical power is not available to supply the airplane load buses airplane battery power will automatically be supplied to the ground refueling circuit when the fueling control panel power switch is placed in the on position Conservative use of airplane battery power for fuel quantity indication is permissible c Momentarily hold fuel quantity repeater indicator gage test switch in...

Страница 3: ...ediately after upward force is applied to tool The sump tool permits a fluid flow rate in excess of 3 gallons per minute creating the siphoning action necessary to remove a maximum amount of free water from the tank sumps and thus reduces corrosion and soaping time b Drain tank sump until water ceases to flow NOTE Fuel tank sumps should be drained after sufficient time approximately 45 minutes for...

Страница 4: ...t position to test indicators pointers will move towards zero when switch is released pointers will return to original quantity 6 Determine fuel load 7 Place center and forward auxiliary tank fuel fill valve control switch in auto fill position verify that tank fill valve manual control lever s moves to open position see Figure 302 8 If applicable tank fuel fill valve s do not open use following p...

Страница 5: ...lbs for forward auxiliary tank 17 If center and forward auxiliary tank fuel fill valve s required manual control to open place boost pump switches in off position when either partial or full tank s fuel loading is attained 18 Place fueling control panel center and forward auxiliary tank fuel fill valve s control switch in closed position 19 If main tank maximum fuel load is desired fuel each main ...

Страница 6: ...drain valves operate identically a Insert probe of drain tool in center recess of sump drain valve and apply upward force NOTE Fuel should flow immediately after upward force is applied to tool The sump tool permits a fluid flow rate in excess of 3 gallons per minute creating the siphoning action necessary to remove a maximum amount of free water from the tank sumps and thus reduces corrosion and ...

Страница 7: ...ovisions ABX Air Inc Printed 8 27 2010 at 12 10 53 PM REV 11 2008 12 11 DC 9 MAINTENANCE MANUAL EFFECTIVITY 900 905 909 928 930 934 939 953 960 962 964 980 984 986 12 12 00 3 CONFIG 00 Page 7 1999 11 15 This page must not be retained for reference ...

Страница 8: ...rol Station ABX Air Inc Printed 8 27 2010 at 12 10 53 PM REV 11 2008 12 11 DC 9 MAINTENANCE MANUAL EFFECTIVITY 900 905 909 928 930 934 939 953 960 962 964 980 984 986 12 12 00 3 CONFIG 00 Page 8 1999 11 15 This page must not be retained for reference ...

Страница 9: ...ueling Transfer Schematic ABX Air Inc Printed 8 27 2010 at 12 10 53 PM REV 11 2008 12 11 DC 9 MAINTENANCE MANUAL EFFECTIVITY 900 905 909 928 930 934 939 953 960 962 964 980 984 986 12 12 00 3 CONFIG 00 Page 9 1999 11 15 This page must not be retained for reference ...

Отзывы: