Administration Manual – Terxon L
6
For each time switch, you can define up to three different on/off times. For each
time switch, you can define the activation time, the deactivation time and the
weekdays.
Important: ...................................................................................................................
You can manually skip a time switch by pressing 0 and then pressing
to
change the current state.
5. As shown on the left, you can now define the on/off time. The number in
brackets shows the time period you are currently defining.
Specify the time (e.g. 21:00h) and confirm with
.
Go to step 7 or press
to exit.
6. You can now define the weekdays on which the time switches are to
trigger. The number at top left shows the period in which the time switch is
active. Press 1–7 to select the weekdays, and confirm with
.
7. Press
and use the number keys to assign the partitions to the
automatic time switches. Confirm the assignment with
. All partition
numbers displayed are assigned. (A “*” means that the partition is not
released, and a “.” means that you have no access to this partition.)
Go to step 4 or press
to exit.
Important: ...................................................................................................................
If the engineer is in the installation menu, the system is also automatically activated.
2.4. Option 4: Test Options
2.4.1. Option 4-1: Walk Test
Under this menu item, you can test that zones are operating correctly. You can
only test partitions to which you have access.
Each tested zone is logged in the event memory. To view the event memory, see
“Option 9-1: View Log” on page 13.
1. Press
to select this option.
2. Confirm
with
to select “Walk Test”.
3. Press the number keys to select the partitions you want to test and confirm
with
.Every partition number displayed is released for the walk test. (A
“*” means that the partition is not tested, and a “.” means that you have no
access to this partition.)
4. Now walk through all your partitions and trigger all sensors.
For each zone that you trigger, the integrated alarm sounders issue a
signal time and the display shows the triggered zone.
5. When you have completed the test, press
.
User Menu
4:Test Options
Auto Set 1
On (1) >00:00
1 Operates On :-
> .......
Auto Set 1
Ptns > **
Test Options 1
Walk Test
Walk Test
Ptns > 1*......
0003 Active
Esc To Stop Test
& View Zones
Содержание Terxon LX
Страница 1: ...Perfect security for home and office Inv 11738099 Terxon LX ADMINISTRATION MANUAL ...
Страница 2: ......
Страница 26: ...Administration Manual Terxon L 24 6 2 User Data No Name Type Partitions 1 Administrator ...
Страница 27: ...Administration Manual Terxon L 25 6 3 Zone Data No Location Door chime Partition ...
Страница 28: ...Administration Manual Terxon L 26 6 4 Maintenance Date Name Work ...