Administration Manual – Terxon L
3
1.4. Exiting the user menu
To return to the normal display, press
repeatedly to jump back through the
menus step by step until the time and date are displayed.
2. Options in the user menu
2.1. Option 1: Omit Zones
You may want to exclude some zones before activating the system. For example,
one room still needs to be used while the rest of the system is activated. This
option allows you to select zones you want to exclude.
Important: ...................................................................................................................
If the system is deactivated, the settings made are deleted. This prevents
zones from being omitted accidentally.
Important: ...................................................................................................................
You can only omit zones that have been set up as omittable (see Installation
Instructions, Option 11).
1. Press
to open the “Omit Zones “menu.
2. Press
the
and
keys or select the zone to be isolated by entering
the 4-digit zone number (please see “Zone Numbers“ on page 16 for
details of numbering).
3. Press
to change the state of the zone (omitted means that the zone
will be omitted).
4. Press
to change to the next zone, or
to exit the menu.
2.2. Option 2: Shunting 24hr Zones
This option allows you to isolate all 24-hour zones in specific partitions. The zones
are then permanently excluded from system monitoring. However, these zones
must have the “Isolate” attribute (see Installation Instructions, Option 11).
Important: ...................................................................................................................
Zones remain shunted until you use the Reinstate 24hr option (see below).
Important: ...................................................................................................................
Reinstating Zones may start the exit timer, depending on the selected setting,
which can be “Unshunt”, “No Exit” or “Unshunt & Exit” (see Installation
Instructions, Option 45).
1. Press
to select Shunt 24-hr Zns.
2. Press 1 to shunt zones or 2 to reinstate shunted zones.
3. Press the number keys to select the partitions you want to shunt or
reinstate, and confirm with
. Every displayed partition is now
shunted/reinstated. (A “*” means that the partition will not be
shunted/reinstated, and “.” means that you have no access to this partition.)
1=Shunt 24hr
2=Reinstate 24hr
Shunt partitions
Ptns > 1*......
User Menu
1: Omit Zones
0002 is Armed
User Menu
2:Shunt 24hr Zns
Содержание Terxon LX
Страница 1: ...Perfect security for home and office Inv 11738099 Terxon LX ADMINISTRATION MANUAL ...
Страница 2: ......
Страница 26: ...Administration Manual Terxon L 24 6 2 User Data No Name Type Partitions 1 Administrator ...
Страница 27: ...Administration Manual Terxon L 25 6 3 Zone Data No Location Door chime Partition ...
Страница 28: ...Administration Manual Terxon L 26 6 4 Maintenance Date Name Work ...