Maintenance
53 |
E N
Maintenance
Danger
Before opening the indoor sounder cover, make sure that the alarm panel is in
installer mode. This prevents the tamper alarm from being triggered.
Test, during routine maintenance, that the indoor sounder works properly.
Check the tamper contacts.
Check for signs of insects having made their way in to the device and clean as required.
Danger
The indoor sounder will not be restarted without completely shutting down.
Note
The device must be disposed of in accordance with the WEEE Directive and
applicable local and national regulations.
Replace the batteries every two years or if the alarm panel displays the message "Flat battery in
indoor sounder". You can find the battery type to be used as a replacement under
Technical data
.
Note
After removing the old batteries, wait 30 seconds before inserting the new batteries.
How to replace the batteries:
•
Put the alarm panel in installer mode.
•
Open the covers for the lid-fixing screws (see Fig. 1), loosen the screws and
open the lid.
•
Disconnect the 12 V power supply
•
Take out the batteries.
•
Wait 30 seconds, then insert the new batteries.
•
Reconnect the 12 V power supply
•
Close the cover, tighten the cover fixing screws and close the covers of the
screws.
•
Test the system.
Danger
The sounder will not be restarted without completely shutting down.
Note
Batteries and the device itself must be disposed of in accordance with the
WEEE Directive and applicable local and national regulations.