Страница 1: ...ABtUS SINGAPORE PTE LTD www abtussingapore com ABtUS SIGAPORE PTE LTD www abtussingapore com 4K HDBT 4x4 Matrix Model MAX HDBT44 P rev 2021 Oct 05 ...

Страница 2: ...g 4K signals up to 40m 1080p up to 70m and powering HDBT HD11R P receivers via a single CAT6 cable It is however recommended to use good quality CAT6 cable The Matrix Switcher supports EDID management and is HDCP 2 2 1 4 compliant Audio sources can be selected via RS232 commands and TCP IP at the Matrix Switcher or by 3rd Party control Support HDMI1 4 HDCP2 2 and compliant with lower standards cap...

Страница 3: ...d IR receiver use the IR remote to control the Matrix Switcher 3 IR OUT 1 4 Plug in the IR Emitter and attach to the front of the Source This then emits the IR signal received from the HDBaseT Receiver There are 4 IR OUTPUT sockets marked on IR matrix 4 OUTPUTS HDBaseT The HDBT RJ45 outputs deliver HD video Audio and PoC to the HDBaseT Receiver up to 70m HDMI Connect an HDMI cable from the Matrix ...

Страница 4: ...g in the IR emitter and attached to the fornt of the display this will send the IR signals form the Matrix Switcher to control the display which is connected to the HDMI OUT port No Name Description 1 Power Indicator OFF No power RED DC power present PoC 2 HDBT IN The RJ45 socket has two LED status indicators Plug in the Preinstalled CAT cable in to the HDBT RJ45 socket HDCP HDCP compliant indicat...

Страница 5: ...le sources and displays Usage Precautions The MAX HDBT44 P 4K Matrix should be installed in a clean and dust free environment Ensure that all plugs power cords and sockets are in good condition without signs of damage All devices should be connected before power on ABtUS MAX HDBT44 P back view Receiver HDBT HD11RP Speaker Out HDMI Out HDMI Out HDMI In HDMI In HDMI In HDMI In LAN RS 232 HDBT Out ...

Страница 6: ... port on Matrix Switcher to control Matrix Switcher by TCP IP protocol 9 Plug in the Power supply adapter 24V DC and tighten to secure Once all components have been connected and the installation is completed switch on the mains supply at the socket Note Connect HDBT ports of Matrix Switcher and far end HDBT HD11RP with a single straight cable IR receivers connected to IR IN should be with carrier...

Страница 7: ...S Input channel selection buttons range from 1 4 corresponding IR signal switched synchronously when switching input channels 3 OUTPUTS Output channel selection buttons 4 Menu buttons ALL EDID CLEAR and ENTER ALL Select all outputs EDID management button Enable input port to manually capture and learn the EDID data of output devices CLEAR Withdraw an operation like switching output channel learnin...

Страница 8: ... port of the Matrix Switcher If the IR receiver connected to HDBaseT receiver or the Matrix Switcher is without an IR carrier signal send the command 0901 to enter infrared carrier enforcing mode and then IR signal can be transferred to IR OUT port By using IR HDBaseT transmission technology the MAX HDBT44 P has some functions as follows 1 Control far end output device from local 2 Control local i...

Страница 9: ...trol far end device from Local Note The IR receiver connected to IR IN must be with IR carrier Control Far end Device locally Connect IR receiver s to IR IN on far end HDBT receiver s and IR Emitter s to IR OUT port of the switcher and use the IR Remote of local source to control the device remotely 1 to 1 Connect an IR receiver to IR IN on far end HDBT receiver and an IR Emitter to IR OUT port of...

Страница 10: ...e as below Control local device from remote Note Send command 0901 to enter infrared carrier enforcing mode if the IR Receiver connected to IR IN of the receiver is not with carrier ABtUS MAX HDBT44 P back view ABtUS MAX HDBT44 P back view Receiver HDBT HD11RP Receiver HDBT HD11RP HDMI Out HDMI Out HDMI Out HDMI Out IR In IR In 1 IR In 2 IR In 3 IR Out IR Out 1 IR Out 2 IR Out 3 HDBT Out HDBT Out ...

Страница 11: ... this port can be placed at IR receiving area of output device or the Matrix Switcher itself x2 Corresponding to the zone receive IR signal from HDBaseT receiver with IR IN port connects with IR receiver number of the Matrix Switcher Example Send command 3R2 to transfer IR signal received from zone 2 to IR OUT port 3 Except the front control panel the Matrix Switcher can be controlled by far end c...

Страница 12: ...e twisted pairs before sending command EDIDUpgrade X 2 In above commands and are symbols for easy reading and do not need to be typed in actual operation 3 Please remember to end the commands with the ending symbols and 4 Type the command carefully it is case sensitive 5 Please set the parameters of COM number baud rate data bit stop bit and the parity bit correctly ...

Страница 13: ... Specifications are subject to changes without notice 13 RS232 COMMUNICATION COMMANDS ...

Страница 14: ...User Operation Guide 14 Specifications are subject to changes without notice RS232 COMMUNICATION COMMANDS ...

Страница 15: ... Specifications are subject to changes without notice 15 RS232 COMMUNICATION COMMANDS ...

Страница 16: ...User Operation Guide 16 Specifications are subject to changes without notice RS232 COMMUNICATION COMMANDS ...

Страница 17: ... Specifications are subject to changes without notice 17 RS232 COMMUNICATION COMMANDS ...

Страница 18: ...User Operation Guide 18 Specifications are subject to changes without notice RS232 COMMUNICATION COMMANDS ...

Страница 19: ...net access or PC s within a LAN Besides IR control RS232 control the Matrix Switcher boasts option TCP IP port for IP control Default settings IP 192 168 1 10 Subnet Mast 255 255 255 0 Gateway 192 168 0 1 Serial Port 4001 IP gateway can be changed as you need Serial Port cannot be changed Connect the Ethernet port of control device and TCP IP port of the Matrix Switcher and set same network segmen...

Страница 20: ...Connect the Matrix Switcher and PC s to the router PC s within the LAN is able to control the Matrix Switcher asynchronously Then it s able to control the device via GUI GUI for TCP IP control MAX HDBT44 P provides with built in GUI for convenient TCP IP control GUI allows users to interact with MAX HDBT44 P through graphical icons and visual indicators Type 192 168 1 10 in your browser it will en...

Страница 21: ...r Enter username and the right password Here is a brief introduction to the interfaces The button matrix displays every possible connection between every input and output users can carry on the connections by clicking corresponding button Buttons 1 9 at the right bottom corner provides quick saving and recall for overall connection status Main Interface shown after logging in provide intuitive I O...

Страница 22: ... RS232 COMMUNICATION COMMANDS Users Display or modify credential settings front panel lock and GUI version Interface Set title bar label and button labels press Save to save the settings If there is any modification press Save to restore the settings or press Cancel to withdraw ...

Страница 23: ...ANDS Configuration Set HDCP Compliance status for every input and manage EDID See the screenshot below Network Inquire and configure network settings including MAC address IP address subnet mask and Gateway Note Logging in as user will restrict the access to the main interface only ...

Страница 24: ...ding the command UpgradeIntEDID x via RS232 Control Software to upgrade the embedded EDID data x 1 5 EDID learning The included IR remote can be used to enable the Matrix Switcher to learn the EDID of all sink devices One input port learns the EDID data of one output port Example Input 2 learns EDID data from output 4 Press EDID INPUTS 2 OUTPUTS 4 ENTER All input ports learn EDID data from one out...

Страница 25: ... Specifications are subject to changes without notice 25 RS232 COMMUNICATION COMMANDS ...

Страница 26: ...26 Specifications are subject to changes without notice TROUBLESHOOTING MAINTENANCE If your problem persists after following the above troubleshooting steps seek further help from authorized dealer or our technical support ...

Страница 27: ...o Output Support PCM Digital Audio Output Supports PCM Dolby DTS DTS HD Frequency Response 20Hz 20KHz Output Connector 1 L R RCA 1 SPDIF CONTROL PARTS Control Ports 4 IR OUT 3 IR IN 1 IR EYE 1 TCP IP female RJ45 1 RS232 3 pin pluggable terminal block Panel Control Front panel buttons RS232 Control 3 pin pluggable terminal block IR Extended IR receiver TCP IP Control Web based GUI GENERAL Power Sup...

Страница 28: ...ABtUS SINGAPORE PTE LTD www abtussingapore com ...