Operating instructions
ABSAAR
9
4) DESCRIPTION AND INDICATIONS OF THE LEDs
Description
and indication
of the "Power"
power supply
button
Indicator of the
charge status of
the internal battery
Press the power supply button
(6)
, the LED indicator
(3)
indicates the charge status of
the internal battery. When charging, the LEDs light up and flash one after the other
until fully charged. This is indicated when all the LEDs are lit.
Description
of the charge
status levels
when recharging
the internal
battery of the
Jumpstarter
The LEDs
(3)
indicate the charge status of the internal battery in relation to the
voltage of the internal battery
0%-25%
LED N
o
1 flashes
25%-50%
LED N
o
1 und N
o
2 flash
50%-75%
LED N
o
1, N
o
2 und N
o
3 flash
75%-99%
LED N
o
1, N
o
2, N
o
3 und N
o
4 flash
100 % (end of charging process)
All the LEDs are lit continuously.
Description
of the charge
statuses when
recharging
the internal
battery of the
Jumpstarter
Press the power supply button
(6)
, the LED indicator
(3)
indicates the charge status
of the internal battery and automatically switches itself off after 30 seconds if no
charge is detected.
100%-75%
All the LEDs are lit.
75%-50%
LED N
o
1, N
o
2 and N
o
3 are lit
50%-25%
LED N
o
. 1 and N
o
. 2 are lit
25%-1%
LED N
o
1 is lit
1%- 0%
LED N
o
1 flashes
0%
All the LEDs are off
Others
Torch LED
lighting
1- Click the "power" power supply button
(6)
once to turn on the device, click a second time
to light the working light
(9)
.
2- click again to activate the warning light
(10)
solid mode, and another time
the warning light flashing
3- click again to activate led torch
(1)
, and another time the led sos strobe light
4- click again to switch off the whole unit
Any time you can turn off the unit by pressing 3 seconds the on/off button
(6)
5) PROCEDURE FOR USING THE START-UP AID
• Ensure that the EJS-260 is fully charged
• Connect the red clamp with the positive and the black clamp with negative pole of the battery
• Insert the jump leads into the outlet
(8)
• Start the car
(The attempt is only allowed to last 5 seconds, after each attempt you have
to wait 60 seconds to cool down the internal battery)
• Remove the jump leads out of the outlet
(8)
• Disconnect the clamps from the battery
• Recharge the EJS-260