6.3 Electrical Connection (to Mains Power)
All work on the electrical equipment (connection, maintenance, repair) is permitted to be performed
only by or under the supervision of a properly qualified technician.
The EcoDrive is designed for connection to an earthed AC mains power system having a rated voltage
between
190 and 240 Volts, 50/60 cps.
Before connecting the power supply line, make sure that your mains power voltage is within the rated
voltage range specified on the nameplate of the EcoDrive.
Connection to mains power is permitted only by means of a multi-contact plug with protection earth
contact. Fixed connection is not permitted.
Connect the following potentials:
Phase
(L1 or L2 or L3)
Neutral conductor (N)
Protection earth
(PE)
The EcoDrive is designed for connection to the following types of mains power systems:
- TN (system with a directly earthed point and with a protection earth conductor (PE) connected to this
point)
- TT
(system with a directly earthed point, the protection earth conductor (PE) not being connected to
this point)
- IT
(system not directly earthed)
TN-System
TT-System
IT-System
ed-1-en
6.3
04-03-10