2 Safety
BAL.0675.0 • 2019-09-16
EN - 5
2.4 Classification of the warnings
The warnings used in the operating instructions are divided into four different categories and are indicated prior to potentially
dangerous work steps. Arranged in descending order of importance, they have the following meanings:
2.5 Specific safety instructions
The device has been developed and manufactured in accordance with state-of-the-art technology and the recognized safety
standards and should be operated according to its designated use as follows:
• for extracting and separating dry, non-flammable welding fumes
• for extracting dust of dust class H13
• for separating smoke from non-alloy and low-alloy steel, e.g. steel with low nickel and chromium content
• for separating smoke from steel with alloy constituents of e.g. nickel and chromium ≤30%
• for extracting smoke from high-alloy steel
Furthermore, the following applies:
DANGER
Describes an imminent threatening danger. If not avoided, this will result in fatal or extremely critical injuries.
WARNING
Describes a potentially dangerous situation. If not avoided, this may result in serious injuries.
CAUTION
Describes a potentially harmful situation. If not avoided, this may result in slight or minor injuries.
NOTICE
Describes the risk of impairing work results or potential material damage to the equipment.
DANGER
Danger of explosion due to use of welding spray
During operation, please observe the following:
• Observe the hazard warnings and safety instructions in the Safety Data Sheet for the welding spray to be used.
• Switch off the fume extraction system before spraying the workpieces with welding spray.
• Do not allow the spray mist to be drawn into the fume extraction system by suction. In a hot system, this may lead to the
formation of flammable/explosive vapour-air mixtures.
WARNING
Health risk due to harmful dust
Before and during operation, please observe the following:
• The extraction system contains harmful dust as of the first use.
• Only qualified personnel are permitted to perform work on the device or system.
• Check and wear your personal protective equipment.
• The extraction system must not be operated without the filter system.
• The extraction system must not be operated with an open dust collecting drawer.
• During operation and the cleaning process, the complete fume extraction system must be kept closed.
NOTICE
• Make sure that the extraction hose is not damaged by being driven over, crushed, torn or similar.
Содержание FEC W3
Страница 30: ...DE 30 BAL 0675 0 2019 09 16 13 Anhang FEC W3 13 Anhang 13 1 Schaltplan Abb 17 Elektroschaltplan 230 V 50 Hz...
Страница 31: ...FEC W3 13 Anhang BAL 0675 0 2019 09 16 DE 31 Abb 18 Elektroschaltplan 230 V 50 Hz...
Страница 32: ...DE 32 BAL 0675 0 2019 09 16 13 Anhang FEC W3 Abb 19 Elektroschaltplan 120 V 50 60 Hz...
Страница 33: ...FEC W3 13 Anhang BAL 0675 0 2019 09 16 DE 33 Abb 20 Elektroschaltplan 120 V 50 60 Hz...
Страница 63: ...FEC W3 13 Appendix BAL 0675 0 2019 09 16 EN 31 Fig 18 Circuit diagram 230 V 50 Hz...
Страница 64: ...EN 32 BAL 0675 0 2019 09 16 13 Appendix FEC W3 Fig 19 Circuit diagram 120 V 50 60 Hz...
Страница 65: ...FEC W3 13 Appendix BAL 0675 0 2019 09 16 EN 33 Fig 20 Circuit diagram 120 V 50 60 Hz...
Страница 95: ...FEC W3 13 Annexe BAL 0675 0 2019 09 16 FR 31 Fig 18 Sch ma de connexion lectrique 230 V 50 Hz...
Страница 96: ...FR 32 BAL 0675 0 2019 09 16 13 Annexe FEC W3 Fig 19 Sch ma de connexion lectrique 120 V 50 60 Hz...
Страница 97: ...FEC W3 13 Annexe BAL 0675 0 2019 09 16 FR 33 Fig 20 Sch ma de connexion lectrique 120 V 50 60 Hz...
Страница 129: ...FEC W3 13 Anexo BAL 0675 0 2019 09 16 ES 33 Fig 18 Esquema de conexiones el ctricas 230 V 50 Hz...
Страница 130: ...ES 34 BAL 0675 0 2019 09 16 13 Anexo FEC W3 Fig 19 Esquema de conexiones el ctricas 120 V 50 60 Hz...
Страница 131: ...FEC W3 13 Anexo BAL 0675 0 2019 09 16 ES 35 Fig 20 Esquema de conexiones el ctricas 120 V 50 60 Hz...