FEC W3
4 Scope of delivery
BAL.0675.0 • 2019-09-16
EN - 9
4 Scope of delivery
Order the equipment parts and wear parts separately.
The order data and ID numbers for the equipment parts and wear parts can be found in the current product catalogue.
Contact details for advice and orders can be found online at
www.binzel-abicor.com.
4.1 Transport
Although the items delivered are carefully checked and packaged, it is not possible to fully exclude the risk of transport
damage.
4.2 Storage
For ambient conditions for storage in a closed environment, see:
Tab. 3 Ambient conditions for transport and storage on page EN-7
5 Functional description
The
FEC W3
extraction system is a mobile filter device for extracting and separating welding fumes in a work area. It is a
welding system component corresponding to welding fume separation class W3 (in accordance with ISO 15012-1).
It is designed for the separation of fumes generated during welding or thermal cutting of steels with alloy constituents such
as nickel or chrome ≤30%, and high-quality steels.
It is made primarily of plastic and has a modular design with a hinged filter housing with cleaning device, and suction, bypass
and emptying nozzle, as well as a mobile frame with integrated control, an extraction system and an air outlet.
The dirty air flows through an air intake fitting that is attached to the side and tangentially into the filter unit, which also
protects the filter from possible damage due to sparks.
The welding fume particles are separated by the cyclone effect and an ancillary filter cartridge. The cleaned air then flows
downward into an exhaust fan and from there back into the work area through an exhaust opening on the back side.
The air volume flow is monitored using differential pressure measurement.
• Fume extraction system with mains connection of 115/230 V
• Extraction hose (l = 5.00 m)
• Rubber connector
• Dust collecting bag (5 pieces)
Tab. 5
Scope of delivery
Goods inspection
Use the delivery note to check that everything has been delivered.
Check the delivery for damage (visual inspection).
In case of complaints
If the delivery has been damaged during transportation, contact the last carrier immediately.
Retain the packaging for potential inspection by the carrier.
Packaging for returns
Where possible, use the original packaging and the original packaging material. If you have
questions concerning packaging and safety during shipment, please consult your supplier,
forwarding agent or carrier.
Tab. 6
Transport
DANGER
Risk of fire
Before installing and operating the extraction system, please observe the following:
• The extraction of welding fumes while welding oil-wetted parts is prohibited.
• The system must not be installed or used in areas that are subject to dust or gas explosion hazards.
• Before putting the system into operation, check whether the operating voltage specified on the nameplate corresponds
to the mains voltage.
Содержание FEC W3
Страница 30: ...DE 30 BAL 0675 0 2019 09 16 13 Anhang FEC W3 13 Anhang 13 1 Schaltplan Abb 17 Elektroschaltplan 230 V 50 Hz...
Страница 31: ...FEC W3 13 Anhang BAL 0675 0 2019 09 16 DE 31 Abb 18 Elektroschaltplan 230 V 50 Hz...
Страница 32: ...DE 32 BAL 0675 0 2019 09 16 13 Anhang FEC W3 Abb 19 Elektroschaltplan 120 V 50 60 Hz...
Страница 33: ...FEC W3 13 Anhang BAL 0675 0 2019 09 16 DE 33 Abb 20 Elektroschaltplan 120 V 50 60 Hz...
Страница 63: ...FEC W3 13 Appendix BAL 0675 0 2019 09 16 EN 31 Fig 18 Circuit diagram 230 V 50 Hz...
Страница 64: ...EN 32 BAL 0675 0 2019 09 16 13 Appendix FEC W3 Fig 19 Circuit diagram 120 V 50 60 Hz...
Страница 65: ...FEC W3 13 Appendix BAL 0675 0 2019 09 16 EN 33 Fig 20 Circuit diagram 120 V 50 60 Hz...
Страница 95: ...FEC W3 13 Annexe BAL 0675 0 2019 09 16 FR 31 Fig 18 Sch ma de connexion lectrique 230 V 50 Hz...
Страница 96: ...FR 32 BAL 0675 0 2019 09 16 13 Annexe FEC W3 Fig 19 Sch ma de connexion lectrique 120 V 50 60 Hz...
Страница 97: ...FEC W3 13 Annexe BAL 0675 0 2019 09 16 FR 33 Fig 20 Sch ma de connexion lectrique 120 V 50 60 Hz...
Страница 129: ...FEC W3 13 Anexo BAL 0675 0 2019 09 16 ES 33 Fig 18 Esquema de conexiones el ctricas 230 V 50 Hz...
Страница 130: ...ES 34 BAL 0675 0 2019 09 16 13 Anexo FEC W3 Fig 19 Esquema de conexiones el ctricas 120 V 50 60 Hz...
Страница 131: ...FEC W3 13 Anexo BAL 0675 0 2019 09 16 ES 35 Fig 20 Esquema de conexiones el ctricas 120 V 50 60 Hz...