BRS-CCi
3 Safety Instructions
EN - 5
2.4 Abbreviations
2.5 Nameplate
The cleaning station
BRS-CCi
is labeled with a nameplate on the inside of the covering hood as follows:
When making any inquiries, please remember the following information:
• Device type, device number, ID-number, year of construction
3 Safety Instructions
Observe the enclosed document Safety Instructions.
1 output of inductive proximity switch (normally open switch) (pnp)
Operating voltage
10 - 30 DC
Allowed residual ripple
Vss < 10 %
Permanent current
max. 200 mA
Current consumption
approx. 4 mA (24 V)
Voltage drop
approx. 1.2 V (200 mA)
1 TCP sensor output
not included in the scope of delivery
Tab. 7
Accessories
Pneumatic motor / nominal speed with oiled air
approx. 650 rpm
Pneumatic motor / air consumption
approx. 380 l/min
Tank volume (release agent)
1 l
Tab. 8
Maintenance unit BRS-CCi
Solid wire
up to 1.6 mm
Filler wire
up to 3.2 mm
Cutting time
0.5 seconds
Tab. 9
Wire cutting device DAV
BRS-CCi
Cleaning station
TCP
Tool Center Point
DAV
Wire cutting device
Tab. 10
Abbreviations