EN - 12
7 Operation
ABIMIG
®
SpinArc
®
7.2 Torch adjustments
7.2.1 Adjusting the rotation diameter
1
Loosen the lower cap and twist it a quarter-turn to the left
.
2
Push the cap downward
.
3
Hold the centre shaft.
4
Hold the positioning wheel
5
using the thumb and index finger of your other hand.
6
Align the position indicator
with the required setting.
If a standard tip adaptor and a flush contact tip are used, the rotation diameter increases by approx.
1 mm with each setting (1-8).
Due to the design of the rotation mechanism, the rotation diameter at the end of the electrode must be
greater than at the contact tip.
The rotation diameter is determined by the free wire end or "stickout", the rigidity of the wire and the
rotational speed. If the rotational speed is increased for a specific stickout and a specific electrode, the
rotation diameter also increases as a result of the centrifugal forces.
WARNING
Risk of burns
Hot surfaces may cause burns.
• Wait until the torch has cooled down sufficiently before touching it.
WARNING
Risk of crushing
Moving parts may cause injury or crushing.
• Switch the control device to OFF before opening the welding torch and adjusting the rotation
diameter.
Fig. 6
Rotation
1
Twist the cap
2
Push the cap downward
3
Positioning wheel
4
Cam
5
Position indicator
Fig. 7
Adjusting the rotation diameter
Rotational drive
Centre of rotation
1
2
3
4
5