8.3 Configuration 

The  SENTRY  can  be  configured  to  work  as  you  like,  depending  on  your  working  environment  and  the  people  using  it.    In 
particular,  you  can  setup  your  SENTRY  to  work  with  different  users,  so  that  your  scan  results  can  be  protected  from 

unauthorised or unintended modification. 

 

a) User administration 

The  SENTRY  software  has  a  user  permissions  feature  which  allows  certain  aspects  of  the  software  to  be  restricted.    For 

example, you can set up the software to prevent changes to the device library, passwords, saved 

PinPrints

 and other SENTRY 

data.   

As delivered, the software has just one user called 

Administrator

.  The Administrator is allowed access to all system functions.  

You can add as many additional users as you like and configure the access permissions for all users differently. 

You will be prompted to select the user when launching the software, and you can also switch to a different user at any time by 
selecting the 

File

 menu and clicking 

Switch User

Each user can have a combination of access permissions which can be enabled or disabled.  These access permissions control 
certain software operations to prevent unauthorised changes to your data.  The current permissions are : 

 

 

Administer Users

 – this permission allows the user to add, delete and edit users, and change user passwords. 

 

Calibrate

 – this permission allows the user to access the hardware calibration for SENTRY. 

 

Manage Device Library

 – this permission allows the user to create, delete and modify devices in the library, and to 

export and import devices. 

 

Manage  Packages  and  Fixtures

  –  this  permission  allows  the  user  to  create,  modify  and  delete  packages  and 

adapters. 

 

Manage  Scan  Profiles

  –  this  permission  allows  the  user  to  change  the  hardware  settings  used  when  performing 

scans. 

 

Adding a user 

To add a new user, click on the 

Administration

 button, then click 

Add

.  Enter a name for the new user and set the access 

permissions you require by checking or unchecking them in the permissions list.  If you wish you can set a password for the 
new user by clicking the 

Set Password

 button and entering the new password.  Click 

OK

 to save the new user. 

 

Editing a user 

You can change the settings for an existing user if necessary.  Click on the 

Administration

 button, then select a user from the 

list and click 

Edit

.  You can then change the permissions or password for the user.  Click 

OK

 to save the new settings. 

 

Deleting a user 

You can remove  a user from  the list, if required,  provided  that the user to  be  deleted is not the current user.   Click  on the 

Administration

 button, then select a user from the list and click 

Delete

.  If you want to delete the current user, switch to a 

different user first. 

 

b) Hardware administration 

Normally your hardware will configure itself automatically when a valid USB connection is present and your SENTRY software is 
running.  However, you can use the 

Hardware Administration

 function to check your hardware if required. 

If you click the 

Hardware

 button, you should see your SENTRY hardware listed with a Ready status.   

 

Product Information 

This  area  displays  the  current  information  about  the  selected  SENTRY  hardware,  its  firmware  version,  the  mother  board 
revision, the socket board revision and the number of channels on the socket board. 

 

Diagnostics 

This area shows the self test results for the selected SENTRY hardware.  If the hardware is functioning correctly then each item 
should have a green tick next to it.  If this is not the case then, report your problem to ABI quoting the 

Product Information

 

and self test 

Diagnostics

Содержание SENTRY

Страница 1: ...tector OPERATOR S MANUAL ABI Electronics Ltd Dodworth Business Park Barnsley S75 3SP United Kingdom 44 0 1226 207420 44 0 1226 207620 sales abielectronics co uk www abielectronics co uk Copyright 2012 2017 ABI Electronics Ltd ...

Страница 2: ...nnection 6 b Input ratings 6 c SENTRY software installation 6 d USB driver installation 6 3 3 Running the software 6 3 4 Quick start guide 7 a Learning a device 7 b Testing a device 7 c Combining PinPrints 7 IV LIBRARY MANAGEMENT a Adding a device to the library 9 b Editing a device 9 c Viewing a device 9 d Deleting a device 9 e Exporting a device 9 f Importing a device 10 g Importing exporting th...

Страница 3: ...Adding a scan profile 21 b Copying a scan profile 21 c Editing a scan profile 21 d Deleting a scan profile 21 VIII OTHER FUNCTIONS 8 1 Choosing reference mode 22 8 2 Adding device documentation 22 8 3 Configuration 23 a User administration 23 b Hardware administration 23 8 4 Calibration 24 8 5 Compensation 24 8 6 Comparison tolerances 25 a Comparison point tolerance 25 b Pin comparison tolerance 2...

Страница 4: ...uipment is used in conjunction with other equipment not supplied by ABI We recommend that you use ABI supplied accessories where possible The SENTRY is designed to operate in Residential Commercial and Light Industrial environments and is not approved for operation in heavy industrial medical automotive or aircraft environments unless confirmed in writing by ABI c Location The SENTRY should be ins...

Страница 5: ...marked to resemble more expensive ICs ICs salvaged from circuit boards It is getting more and more difficult to ensure that the components you purchase are genuine The vast majority of dealers world wide are honest and genuine but there are unfortunately some rogue dealers who will try to make money by attempting to sell non genuine components c SENTRY hardware operation The ABI SENTRY is an elect...

Страница 6: ...ects to a standard PC via a high speed USB interface The SENTRY operating software on your PC controls all system operations and functions and provides full database facilities for storage and reporting of PinPrints from genuine devices and manufacturers e PC requirements The ABI SENTRY control software runs on a PC with the following minimum specifications Microsoft Windows XP Vista or 7 operatin...

Страница 7: ...een You may see a security warning during the installation d USB driver installation Connect the SENTRY unit to a suitable mains supply and switch on then connect the unit to a spare high speed USB 2 0 port on your PC with the cable supplied After a few seconds you will see the message Found New Hardware ABI SENTRY Counterfeit IC Detector You may also see a warning message if the USB port selected...

Страница 8: ...indication of date time and user will be displayed in the PinPrint section Note that the Clear button can be used to delete saved PinPrints The acquisition of reference PinPrints is now complete For the purpose of this guide leave the IC in the socket and move to the next section by clicking Test from the left hand side menu b Testing a device This section is aimed at testing devices by comparing ...

Страница 9: ... devices which match your criteria This can also be used in conjunction with the device type filter to further refine a search for a specific device The device type filter By selecting a type from the list the SENTRY software will search through your device library and return only devices which match this type This can also be used in conjunction with the device text filter to further refine a sea...

Страница 10: ...can accurately scan the device You have now completed adding a new device Click OK to save the device into your library b Editing a device Note the Edit button is only visible if the device is eligible for editing If you want to change any of the settings for a device select the device from the list and click the Edit button You can then change any of the settings as described in the section above...

Страница 11: ... library click on the Select All button in the library section and click on Export The devices will be exported individually to a destination of your choice To import multiple devices to a library click on Import in the library section and browse to the location of the devices on your computer Hold the CONTROL key down on the keyboard and select the devices required Alternatively use the CONTROL S...

Страница 12: ...his can also be used in conjunction with the other filters to further refine a search for a specific package The description filter By typing part or all of a package description the SENTRY software will search through your package library and return only packages which match that description This can also be used in conjunction with the other filters to further refine a search for a specific pack...

Страница 13: ...pe as the previous pin added The properties of the pin size location shape number are displayed in the property grid at the bottom of the window when a pin is selected You can change the properties of the pin by resizing with the mouse and or by using the controls in the pin property grid Add shape tool for adding shapes to your package The properties of the shape size location colour style are di...

Страница 14: ...ight click on the pin which you want to be the next number in the sequence The number of the pin will be set to the next number down from the previous one Continue double right clicking on all pins in the order you want to renumber the entire package Automatic renumber This function will start from the pin you select and renumber all higher numbered pins in sequence This means you can quickly crea...

Страница 15: ...the extension PKG will be created in the chosen location To export multiple packages hold the CONTROL key down on the keyboard and select the packages to be exported Alternatively use the CONTROL SHIFT keys to select a complete list of packages Click Export to export the packages individually h Importing a package To import a package click the Import button and browse to the PKG file for the packa...

Страница 16: ...n conjunction with the other filters to further refine a search for a specific Adapter The package type filter By selecting a type from the list the SENTRY software will search through your Adapter library and return only those which have packages which match this package type This can also be used in conjunction with the other filters to further refine a search for a specific Adapter The descript...

Страница 17: ...you insert a 14 pin DIL IC in the rear of the socket this means that pin 1 of the IC connects to channel 1 of the SENTRY pin 2 to channel 2 and so on However pin 14 of the IC on the other side connects to channel 48 of the SENTRY as shown in the table Pin 13 connects to channel 47 and so on There is an Adapter included as standard for this scenario called 14 pin DIL in 48 pin ZIF This Adapter is u...

Страница 18: ...guidance when inserting ICs The label will resize itself automatically depending on the text and chosen font You can change the location of the label by dragging with the mouse and or by using the controls in the label property grid Add package tool for adding pre defined packages to your Adapter The location of the package is displayed in the property grid at the bottom of the window when a packa...

Страница 19: ...m the previous one Continue double right clicking on all pins on all packages in the order you want to allocate channel numbers for the entire Adapter c Editing an adapter Note the Edit button is only visible if the Adapter is eligible for editing If you want to change any of the information or design for an Adapter select it from the list and click the Edit button You can then change the informat...

Страница 20: ...dapters to be exported Alternatively use the CONTROL SHIFT keys to select a complete list of adapters Click Export to export the adapters individually h Adapter files The packages you design are stored as text files in the Adapters folder on your computer hard drive These files are human readable but you should not attempt to edit them as you may cause unexpected problems and your changes may be o...

Страница 21: ...lected profile to the library see section 0 for more information Note this button is only enabled if a profile is selected in the profile list Error Reference source not found The Delete button This button allows you to remove a profile from the library Note this button is only enabled if a profile is selected in the profile list The Hardware status Shows the current status of the connected hardwa...

Страница 22: ...or the device s you are going to test The Scan Profile is now complete and you can save and exit by clicking the OK button or continue to editing profiles b Copying a scan profile To copy a profile select it from the profile list and click the Copy button to create a blank profile called Copy of your selected Scan Profile name Select the profile in the profile list and it is then possible to chang...

Страница 23: ... pin count devices these modes take more time 8 2 Adding device documentation In the Learn section click on the Documentation tab In this section you can add various documents and graphics to help in identifying counterfeit ICs You can add pictures either from a file or from a USB camera connected to your PC and documents such as device data sheets etc You can add any type of document that you can...

Страница 24: ...apters Manage Scan Profiles this permission allows the user to change the hardware settings used when performing scans Adding a user To add a new user click on the Administration button then click Add Enter a name for the new user and set the access permissions you require by checking or unchecking them in the permissions list If you wish you can set a password for the new user by clicking the Set...

Страница 25: ...y requires the user to enter a few voltage readings in the initial stages Continue to follow the on screen instructions until calibration is complete When calibration is completed click Next to save the calibration to the SENTRY unit at this point the SENTRY is automatically reset and should be ready for use immediately If you experience problems after calibration power down the SENTRY wait 5 seco...

Страница 26: ...al tolerance The percentage of the total range that the measurement needs to be within in the horizontal direction for the data to be deemed valid Vertical The percentage of the total range that the measurement needs to be within in the vertical direction for the data to be deemed valid It is possible to restore the default settings for these by clicking the Restore Default button which sets all t...

Страница 27: ...ors can also be used Component Reference images If images and photos have been added to the device documentation see section 8 2 they can also be added to the report Select the image from the list available and with the left mouse key still pressed drag the image to the area under component or reference as required Resize functions All images diagrams and PinPrints can be resized as required The R...

Отзывы: