16
17
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
MOTOR B SETTINGS
Motor B can be configured using 8 parameters identified by the letter
b
.
sec = seconds % = percentage parameter n = disabled
Times are expressed in seconds
Forces and thresholds are expressed in decimals and correspond to %. Ex:
01
= 10%
b1
STANDARD TIME
14 sec
b5
STANDARD FORCE (from 10% to 100%)
8/10 %
b2
SLOWDOWN TIME
7 sec
b6
SLOWDOWN FORCE (from 10% to 100%)
10/10 %
b3
SOFT START (ACHIEVING SET TORQUE)
0,8 sec
b7
STANDARD OBSTACLE DETECTION THRESHOLD
n %
b4
WAITING TIME BEFORE CLOSING
6 sec
b7
SLOWDOWN OBSTACLE DETECTION THRESHOLD
n %
b1
STANDARD TIME
MINIMUM:
0.0
sec
MAXIMUM:
99
sec
Motor B works for
B1
seconds at force
B5
. At the end of this time, motor B slows down. This occurs during both opening and closing.
Motor B closes before motor A. Motor B opens
B4
seconds after motor A.
b2
SLOWDOWN TIME
MINIMUM:
0.0
sec
MAXIMUM:
99
sec
Motor B slows down for
b2
seconds at force
b6
. The slowdown phase is performed after the normal working time for both opening and
closing. To disable the slowdown of motor B, set the parameter
b2
=
0.0
sec.
b3
SOFT START (ACHIEVING SET TORQUE)
MINIMUM:
0.1
sec
MAXIMUM:
1.5
sec
When starting, motor B gradually increases the force until it reaches the set force
b5
. During this time the obstacle detection sensor is
disabled.
b4
DELAY AT CLOSING (MOTOR B)
MINIMUM:
0.0
sec
MAXIMUM:
a1
+
a2
sec
Motor B opens
b4
seconds after motor A. This time is useful to avoid overlapping of the doors during the opening phase.
b5
TORQUE ADJUSTMENT/STANDARD FORCE
MINIMUM:
01
= 10%
MAXIMUM:
10
= 100%
During STANDARD TIME
b1
the force of motor B is
b5
% of the total. The force of motor B can be set from 10% to 100% in steps of
10%. The force of the motor increases or decreases the sensitivity of the obstacle sensor. The greater the force set, the lower the sensitivity.
The lower the force, the greater the sensitivity.
b6
TORQUE ADJUSTMENT/STANDARD FORCE
MINIMUM:
01
= 10%
MAXIMUM:
10
= 100%
During SLOWDOWN TIME
b2
the force of the motor is
b6
% of the total. The SLOWDOWN FORCE can be set from 10% to 100% in
steps of 10%. The force of the motor increases or decreases the sensitivity of the obstacle sensor: the greater the force set, the lower the
sensitivity; the lower the force set, the higher the sensitivity.
b7
STANDARD OBSTACLE
MINIMUM:
00
= 0%
MAXIMUM:
n
= disabled
If the force of motor B detected is greater than the STANDARD OBSTACLE THRESHOLD
b7
set during STANDARD TIME
b1
the control
unit detects an obstacle. If the force of motor B detected is greater than the set threshold, the gate reverses the movement if it is the first
detection in the working cycle, otherwise it goes to the limit switch. Once the obstacle is detected, the gate performs a safety procedure
by moving one door at a time.
In order to facilitate calibration of the STANDARD OBSTACLE THRESHOLD, the control unit’s display during CLOSING shows the force of
motor B as a number from
00
to
99
. To disable obstacle detection press the (+) KEY until the display shows
n
.
b8
SLOWDOWN OBSTACLE THRESHOLD
MINIMUM:
00
= 0%
MAXIMUM:
n
= disabled
During the SLOWDOWN TIME
b2
the control unit detects an obstacle if the force of the motor is greater than the SLOWDOWN OBSTA-
CLE THRESHOLD
b8
set. Obstacle detection during slowdown acts as a limit switch.
In order to facilitate calibration of the SLOWDOWN OBSTACLE THRESHOLD, the control unit’s display during CLOSING shows the force of
motor B as a number from
00
to
99
. To disable obstacle detection during slowdown press the (+) KEY until the display does not show
n
.