USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
FACTORY SETTINGS
A
MOTOR A
A1
STANDARD TIME
A2
SLOWDOWN TIME
A3
START TIME
A4
WAITING TIME BEFORE CLOSING
A5
STANDARD MOTOR FORCE
A6
SLOWDOWN MOTOR FORCE
A7
STANDARD OBSTACLE THRESHOLD
A8
SLOWDOWN OBSTACLE THRESHOLD
MOTOR A
description
A1
14
sec
STANDARD TIME
A2
7
sec
SLOWDOWN TIME
A3
0,8
sec
START TIME
A4
0,6
sec
WAITING TIME BEFORE CLOSING
A5
0,8
%
STANDARD MOTOR FORCE
A6
10
%
SLOWDOWN MOTOR FORCE
A7
n
%
STANDARD OBSTACLE THRESHOLD
A8
n
%
SLOWDOWN OBSTACLE THRESHOLD
MOTOR B
description
B1
14
sec
STANDARD TIME
B2
7
sec
SLOWDOWN TIME
B3
0,8
sec
START TIME
B4
0,3
sec
WAITING TIME BEFORE OPENING
B5
0,8
%
STANDARD MOTOR FORCE
B6
10
%
SLOWDOWN MOTOR FORCE
B7
n
%
STANDARD OBSTACLE THRESHOLD
B8
n
%
SLOWDOWN OBSTACLE THRESHOLD
FUNCTIONS
description
F0
10
sec
AUTO-CLOSE TIME
F1
6
sec
PEDESTRIAN TIME
F2
n
y/n
KICK BACK FUNCTION AT CLOSING
f3
1
sec
PRE-BLINKING TIME
f4
n
y/n
KICK BACK FUNCTION AT OPENING
f5
n
y/n
STEP BY STEP
f6
n
y/n
MULTIPLE RESIDENTS
f7
n
y/n
EXTENDED FAST CLOSURE
f8
n
y/n
PHOTOCELLS LOGIC: SLIDING
l0
0
0,1,2,3
ELECTRIC LOCK
INPUTS
description
E0
2
NEGATIVE INPUT REFERENCE
E1 go
TERMINAL 9 - START FUNCTION
E2 PE
TERMINAL 10 - PEDESTRIAN
FUNCTION
E3
n
TERMINAL 11 – DISABLED
E4
n
TERMINAL 12 – DISABLED
E5
n
TERMINAL 13 – DISABLED
E6
n
TERMINAL 22 – DISABLED
E7
n
TERMINAL 23 – DISABLED
E8
n
TERMINAL 24 – DISABLED
E9
n
TERMINAL 25 – DISABLED
B
MOTOR B
B1
STANDARD TIME
B2
SLOWDOWN TIME
B3
START TIME
B4
WAITING TIME BEFORE CLOSING
B5
STANDARD MOTOR FORCE
B6
SLOWDOWN MOTOR FORCE
B7
STANDARD OBSTACLE THRESHOLD
B8
SLOWDOWN OBSTACLE THRESHOLD
t
TESTS
t1
PHOTOCELLS TEST
t2
MOTORS TEST
d
FACTORY SETTINGS
d0
RESTORING INITIAL VALUES
p
GUIDED PROGRAMMING
p1
GUIDED PROGRAMMING 1 MOTOR
p2
GUIDED PROGRAMMING 2 MOTORS
p6
OBSTACLE SENSOR PROGRAMMING
KEYS
←
RUN FROM
p6
TO
a1
→
RUN FROM
a1
TO
p6
+
INCREASE / ENABLE
-
INCREASE / ENABLE
o
PROGRAMMABLE OUTPUTS
o1
RELAY MODULE FUNCTION PLUG-IN 1
o2
RELAY MODULE FUNCTION PLUG-IN 2
r
RADIO
r0
GATE CODE
r1
START
r2
STOP
r3
PEDESTRIAN
r4
FAST CLOSURE
r5
DELETE ALL CODES
r6
PROGRAMMABLE FUNCTION
r7
PROGRAMMABLE FUNCTION
r9
PLUG-IN RADIO MODULE FUNCTION
f
/
l
GENERAL FUNCTIONS
f0
AUTO-CLOSE TIME
f1
PEDESTRIAN TIME
f2
KICK BACK FUNCTION AT CLOSING
f3
PRE-BLINKING TIME
f4
KICK BACK FUNCTION AT OPENING
f5
STEP BY STEP
f6
MULTIPLE RESIDENTS
f7
FAST CLOSURE ON ALL CONTROLS
f8
PHOTOCELLS LOGIC: SLIDING
l0
ELECTRIC LOCK - FLASHING LIGHT
l1
MOTOR OIL RECIRCULATION
l3
ONLY MOTOR A MODE
l4
RESTORING MANOEUVRE WITH
DEAD MAN FUNCTION
l5
WORKING CYCLES ASSISTANCE
REQUEST
l6
TOTAL WORKING CYCLES COUNTER
The procedures that restore the factory settings can be identified on the menu by the letter d.
d0
RESTORATION OF INITIAL PARAMETER SETTINGS
This procedure DOES NOT DELETE previously saved remote controls from the memory. To restore the initial settings:
1. Select the parameter
d0
using the keys (
←
) or (
→
).
2. After 2 seconds the symbol
n
will appear on the display.
3. Keep the (+) KEY pressed down: the display will flash showing
y
4. After about 2 seconds the control unit shows
--
: the factory values have been restored and the control unit will automatically
exit from the menu. Now, you can release the (+) KEY.
INITIAL SETTING VALUES
FUNCTIONS
description
L1
0
min
MOTOR HEATING / OIL RECYCLING
L3
n
y/n
1 MOTOR MODE
L4
n
y/n
RESTORING MANOEUVRE WITH DEAD
MAN FUNCTION
L5
n
y/n
PERIODIC ASSISTANCE
TESTS
description
T1
n
y/n
PHOTOCELLS TEST
T3
y
y/n
MOTORS TEST
RADIO
description
r6
p0
DEAD MAN OPENING
r7
pc
DEAD MAN CLOSING
r9
go
PLUG-IN RADIO - START FUNCTION
PARAMETERS NOT DESCRIBED ON THIS PAGE ARE LINKED TO PROCEDURES AND THEREFORE DO NOT HAVE AN INITIAL VALUE.