USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D 

GENERAL FUNCTIONS

f7

FAST CLOSURE

MINIMUM: 

n

MAXIMUM: 

y

The FAST CLOSURE function allows the gate to be closed after passing in front of both photocells (open and close or close and open). 
Closing begins 5 seconds after passing in front of the photocells. This function is only enabled once per WORKING CYCLE and if the gate 
movement is not interrupted.
If 

F7

 = all START orders initiate this function: the remote controls stored with the functions 

r1

 START

r3

 PEDESTRIAN

r4

 FAST 

CLOSURE, the terminal board inputs associated with the START 

go

 , OPEN 

oP

 or PEDESTRIAN functions 

pe

. If 

F7

 = 

n

 (disabled) only 

remote controls stored with the radio function 

r4

 activate the FAST CLOSURE.

F8

PHOTOCELLS LOGIC: SLIDING

MINIMUM: 

n

MAXIMUM: 

y

If 

F8

 = 

n

 the photocells operate with the logic of SWING GATE automation:

- OPENING PHOTOCELLS (terminal 13 parameter 

E5

 = 

tA

): suspend the OPENING as long as the beam is interrupted. Reverses the 

movement status from CLOSING to OPENING SUSPENDED. During OPENING they have no effect on the ongoing operation.

- CLOSING PHOTOCELLS (terminal 12 parameter 

E4

 = 

tc

 ,

E4

 = 

td

): reverse the movement from CLOSING to OPENING.

If 

F8

 = 

y

 the photocells operate with the logic of SLIDING automation:

- OPENING PHOTOCELLS (terminal 13 parameter 

E5

 = 

tA

): during OPENING they reverse the movement for 3 seconds. After these 3 

seconds, CLOSING is interrupted. A subsequent START order starts the gate in CLOSING mode.

They have no effect during the CLOSING operation.
- CLOSING PHOTOCELLS (terminal 12 parameter 

E4

 = 

tc

E4

 = 

td

): reverse the movement from CLOSING to OPENING. They have 

no effect during the OPENING operation.

L0

KICK BACK

MINIMUM: 

0

MAXIMUM: 

3

This parameter allows changes to be made to the operating logic of terminals 20 + e 21 - (

L0

) associated with the electric lock. This output 

is useful for controlling a 12VDC electric lock or a 3 W 12 VDC LED flashing light. The output of the electric lock can also be controlled by 
remote control.

L0

 = 

00

 

 The output is disabled. Only remote controls associated with the function 

EL 

(activate the electric lock for 3 seconds) can 

activate the control unit’s output 20 + e 21 - (

L0

). The activation of the electric lock by remote control can be useful to manage a pedestri-

an gate adjacent to the automatic gate.

L0

 = 

01

 

 The output is enabled to manage an electric lock installed on the door moved by motor A. At the beginning of each

OPENING movement, the control unit releases the electric lock. Remote controls stored as 

EL

 unlock the electric lock.

L0

 = 

02

 

 The output is enabled with an intermittent flashing function. During OPENING, the flashing light will perform fast flashes. 

During CLOSING the flashes will be slow. During the automatic closing time, the flashing light is
permanently lit.

L0

 = 

03

 

 The output is enabled with the steady light function during the operation. During OPENINGCLOSING and the AUTOMATIC 

CLOSING TIME the flashing light is on.

L1

OIL RECYCLING / MOTOR HEATING

MINIMUM: 

0

 min

MAXIMUM: 

8

 min

With this function it is possible to heat the motors and the control unit box cyclically. In the case of systems with hydraulic motors, it is 
useful to circulate the oil periodically: each cycle lasts 10 minutes and 

L1

 represents the minutes that the motor/box is heated in each 

cycle. This function is activated after 10 minutes with the gate fully closed or open: any operation on the control unit or interruption of a 
photocell resets the time count to zero. The motors are active in the final part of each cycle. For example, by setting 

L1

 = 

03

 the motors 

remain switched off for 7 minutes and then switched on for the remaining 

3

 minutes after the function is active (i.e. after 17 minutes from 

the last operation performed).

L3

ONLY MOTOR A MODE

MINIMUM: 

0

MAXIMUM: 

y

By enabling this function 

L3

 = 

y

 only motor A will be managed. The parameters relating to motor B ( 

b1

 – 

b8

) can no longer be mod-

ified. This function is useful when installing a 1 door swing gate or sliding gates. If this control unit is used on a sliding gate, set parameter 

F8

 = 

y

 to select the correct photocell logic.

Содержание 051D

Страница 1: ...n inputs Positive or negative inputs Dead man s function Soft start Technical data Motors 600W each motors Flashing lamp max 60W 230 VAC Power supply 24 VDC max 250mA AB2101 VERSION APE 570 0510 with radio module APE 570 0511 without radio module USER MANUAL AB00093 rev 02 del 01 2022 1 motor mode Flashing light 230 vac vdc Photocells test Motors test Compatible with plug in Faac radio receiver Te...

Страница 2: ...QUE ADJUSTMENT STANDARD FORCE 17 TORQUE ADJUSTMENT SLOWDOWN FORCE 17 STANDARD OBSTACLE TRESHOLD 17 SLOWDOWN OBSTACLE TRESHOLD 17 OBSTABLE SENSOR PROGRAMMING 18 AUTOMATIC OBSTACLE SENSOR PROGRAMMING 18 FUNCTION OVERVIEW 19 AUTO CLOSE TIME 19 PEDESTRIAN TIME 19 KICK BACK FUNCTION AT CLOSING 19 PRE BLINKING TIME 19 KICK BACK FUNCTION AT OPENING 19 STEP BY STEP MODE 19 COMMUNITY MODE 19 STANDARD MODE ...

Страница 3: ...polar switch with contact opening distance equal to or greater than 3 mm should be installed on the power supply of the automatic gate The use of a 6A thermomagnetic circuit breaker with omnipolar switch is recommended 12 Check that there is a differential switch with a 0 03A threshold upstream of the system 13 Check that the earthing system is properly installed and connected to the metal parts o...

Страница 4: ...PS MOTOR B MOTOR A THE LIGHT IS OPEN WHEN ONE OF THE TWO MOTORS IS MOVING GENERAL PE N L GROUND NEUTRAL PHASE MOTOR A 600 W 230 VAC 1 2 3 COMMON OPEN CLOSE MOTOR B 600 W 230 VAC 4 5 6 COMMON OPEN CLOSE LIGHT 60 W 230 VAC 7 8 COMMON OPEN PLUG IN FOR RECEIVER FUSE 5A 230 VAC PLUG IN FOR RECEIVER 2 ...

Страница 5: ...YOUT TYPICAL SWING GATE INSTALLATION The system must have a physical limit in the opening and closing movement Antenna Flashing lamp Motor B Closing photocells Pedestrian access INTERNAL AREA OF THE GATE opening photocells Motor A opens first Motor A opens first 051D MDR ...

Страница 6: ...13 14 15 16 17 18 19 20 21 TRANSMITTER GATE ELECTRIC LOCK FLASHING LAMP STEADY LIGHT FLASHING LIGHT PHOTOCELL OPENING PHOTOCELL CLOSING STOP START PEDESTRIAN LIMIT SWITCH OPENING LIMIT SWITCH CLOSING LIMIT SWITCH OPENING LIMIT SWITCH CLOSING To use the PHOTOCELL TEST FUNCTION connect the negative pole of the transmitters to the t1 terminal block and activate this function with t1 Y ...

Страница 7: ...13 14 15 16 17 18 19 20 21 TRANSMITTER GATE ELECTRIC LOCK FLASHING LAMP STEADY LIGHT FLASHING LIGHT PHOTOCELL OPENING PHOTOCELL CLOSING STOP START PEDESTRIAN LIMIT SWITCH OPENING LIMIT SWITCH CLOSING LIMIT SWITCH OPENING LIMIT SWITCH CLOSING To use the PHOTOCELL TEST FUNCTION connect the negative pole of the transmitters to the t1 terminal block and activate this function with t1 Y ...

Страница 8: ...etected by the control unit that sets the parameter of the terminal block to the correct safety fuction in this case E3 St STOP This feature is called AUTO ENABLE E4 TERMINAL BLOCK 12 E4 NORMALLY CLOSED Terminal block 12 is associated with a normally closed N C contact The parameters that can be set are N DISABLED tc CLOSING PHOTOCELL MODE 1 and td CLOSING PHOTOCELL MODE 2 This control unit is sup...

Страница 9: ...ith a normally closed N C contact The parameters that can be set are n DISABLED ob LIMIT SWITCH OPENING MOTOR B This control unit is supplied with the standard setting where terminal block 24 is disabled E9 n When a NORMALLY CLOSED contact is connected to terminal block 24 it is automatically detected by the control unit that sets the parameter of the terminal block to the correct safety fuction i...

Страница 10: ...i scorre la lista dei parametri velocemente 2 Dopo circa 2 secondi il display mostrerà il valore di F0ad esempio10 secondi 3 Mantenere premuto il TASTO La centrale incrementerà velocemente il valore fino a che non mostrerà 5t Quando il display mostrerà 5t la CHIUSURA AUTOMATICA sarà disabilitata e il cancello rimarrà aperto al termine della fase di apertura 5 5t t indica STOP al termine dell apert...

Страница 11: ...r B standard time A1 b1 slowdown time A2 b2 and auto close time F0 configuration If you disabled the slowdown time of one of the motors or both ignore A1 and or b1 _ _ After 2 seconds two dashes will appear on the display Perform a START command to start A1 configuration A1 You are working on motor A STANDARD TIME Motor A starts the opening movement When the leaf controlled by motor A has complete...

Страница 12: ... TESTS t1 PHOTOCELLS TEST t2 MOTORS TEST d FACTORY SETTINGS d0 RESTORING INITIAL VALUES p GUIDED PROGRAMMING p1 GUIDED PROGRAMMING 1 MOTOR p2 GUIDED PROGRAMMING 2 MOTORS p6 OBSTACLE SENSOR PROGRAMMING KEYS RUN FROM p6 TO a1 RUN FROM a1 TO p6 INCREASE ENABLE INCREASE ENABLE o PROGRAMMABLE OUTPUTS o1 RELAY MODULE FUNCTION PLUG IN 1 o2 RELAY MODULE FUNCTION PLUG IN 2 r RADIO r0 GATE CODE r1 START r2 ...

Страница 13: ...ERMINAL 11 DISABLED E4 n TERMINAL 12 DISABLED E5 n TERMINAL 13 DISABLED E6 n TERMINAL 22 DISABLED E7 n TERMINAL 23 DISABLED E8 n TERMINAL 24 DISABLED E9 n TERMINAL 25 DISABLED The procedures that restore the factory settings can be identified on the menu by the letter d d0 RESTORATION OF INITIAL PARAMETER SETTINGS This procedure DOES NOT DELETE previously saved remote controls from the memory To r...

Страница 14: ... OPENING PHOTOCELL CLOSING PHOTOCELL The OPENING PHOTOCELL and CLOSING PHOTOCELL MODE 1 functions are active at the same time e4 12 e5 13 tc CLOSING PHOTOCELL MODE 1 The CLOSING PHOTOCELL MODE 1 function reverses the move ment during the closing phase and it has no effect during the opening phase If the CLOSING PHOTOCELL MODE 1 function is active and the gate is stopped it will NOT be started in O...

Страница 15: ... is reported after automatic programming of SENSOR p6 Error 9P indicates that one or more parameters related to the obstacle sensor have not been calibrated To check which parameters are not programmed check the value of the following parameters p6 p7 b7 and b8 see CONFIG URATION MOTOR A B The parameters set to n have not been programmed ab LIMIT SWITCH MOTOR A LIMIT SWITCH MOTOR B The function LI...

Страница 16: ... STANDARD FORCE MINIMUM 01 10 MAXIMUM 10 100 During STANDARD TIME A1 the force of motor A is A5 of the total The force of motor A can be set from 10 to 100 in steps of 10 The force of the motor increases or decreases the sensitivity of the obstacle sensor the greater the force set the lower the sensitivity the lower the force set the higher the sensitivity A6 TORQUE ADJUSTMENT STANDARD FORCE MINIM...

Страница 17: ...om 10 to 100 in steps of 10 The force of the motor increases or decreases the sensitivity of the obstacle sensor The greater the force set the lower the sensitivity The lower the force the greater the sensitivity b6 TORQUE ADJUSTMENT STANDARD FORCE MINIMUM 01 10 MAXIMUM 10 100 During SLOWDOWN TIME b2 the force of the motor is b6 of the total The SLOWDOWN FORCE can be set from 10 to 100 in steps of...

Страница 18: ...ue If they are set to n that parameter has not been programmed Changing the force of the motor may change the programming result Example When programming is complete the display shows9p Suppose that the normal force of motor B has not been programmed The numbers given in the example are for illustration purposes only and may vary from installation to installation At the end of procedure p6 the con...

Страница 19: ...RIAN order behaves exactly like a START order f2 KICK BACK MINIMUM 0 0sec MAXIMUM 2 5 sec At the end of the closing process after having performed any slowing down phase motor A pushes on the stop at maximum force for F2 se conds This function can be useful when using the electric lock when closing is difficult During this operation the obstacle sensor is disabled f3 PRE BLINKING TIME MINIMUM 0 0 ...

Страница 20: ...ic lock can also be controlled by remote control L0 00 The output is disabled Only remote controls associated with the function EL activate the electric lock for 3 seconds can activate the control unit s output 20 e 21 L0 The activation of the electric lock by remote control can be useful to manage a pedestri an gate adjacent to the automatic gate L0 01 The output is enabled to manage an electric ...

Страница 21: ...ds This function can be useful for alerting the end user to the need for system maintenance The parameter L5 can be set in these ranges n disabled from 0 1 to 0 9 from 1 to 9 working cycles from 1 1 to 1 9 from 10 to 90 working cycles from 2 1 to 2 9 from 100 to 900 working cycles from 3 1 to 3 9 from 1000 to 9000 working cycles from 4 1 to 4 9 from 10000 to 90000 working cycles from 5 1 to 5 9 fr...

Страница 22: ...uccessful the required operation is started If the check fails the control unit display will indicate 1t and the gate will not be started The photocell test will only be carried out on installed photocells For example if the system only uses the photocell when closing ensure that parameter e4 is set to tC or td functions relating to the photocell and that the parameter e5 is disabled e5 n see GENE...

Страница 23: ...ciated is displayed SAVING A REMOTE CONTROL AS START 1 Select the parameter r1 using the scroll keys or 2 After a few seconds the display shows _ 3 Hold down the button on the remote control to be stored The display shows _ 4 Press the KEY on the control unit The display shows 1 The remote control has been successfully stored in position 1 of the con trol unit memory display 2 memory position 2 di...

Страница 24: ...d as described in the STORE A REMOTE CONTROL paragraph To ASSOCIATE A NEW FUNCTION select parameter r6 or r7 Hold down the KEY The display starts flashing showing r6 or r7 When it stops flashing release the KEY Change the function using the KEY The function initially associated with r6 is po DEAD MAN OPENING The function initially associated with r7 is pC DEAD MAN CLOSING r9 PLUG IN RADIO The PLUG...

Страница 25: ...trolling an electric lock through a radio device or for signalling a dead man opening closing movement USCITE PROGRAMMABILI I parametri di gestione delle uscite programmabili sono identificabili sul menù dalla lettera O Per poter usare queste funzioni sono necessari dei moduli di espansione RELAY APE 570 0022 da collegare ai di connessione presenti sulla centrale o1 o2 USCITE PROGRAMMABILI 1 e 2 L...

Страница 26: ...Using the KEYS select the Po function 6 Using KEYS select the parameter o1 o2 7 Using the KEYS select the 06 function 8 Exit the menu using the KEYS When the remote control button stored following the above procedure is transmitting the gate will move in the OPEN direction and simultaneously the output will be activated EXAMPLE configure a remote control to signal a dead man closing movement 1 Sto...

Страница 27: ...mbiente e sulla salute e favorisce il reimpiego e o riciclo dei materiali di cui è composta l apparecchiatura Lo smaltimento abusivo del prodotto da parte dell utente comporta l applicazione delle sanzioni di cui alla corrente normativa di legge www abtecno com 27 27 PRODUCT DISPOSAL A Declaration for household EEE without batteries or portable accumulators INFORMATION FOR USERS OF DOMESTIC OR PRO...

Страница 28: ...AUTOMATION ACCESSORIES ABEXO is a registered trademark property of AB TECNO srl Via Cicogna 95 40068 San Lazzaro di Savena BO info abtecno com www abexo tech ...

Отзывы: