background image

Operating instruction manual 

| TX Thermal Disperson Level Switches   23 

14.0 WARRANTY STATEMENT

5 YEAR WARRANTY FOR:

KM26 Magnetic Liquid Level Gauges; MagWave Dual Chamber System; LS Series Mechanical Level Switches (LS500, LS550, 

LS600, LS700, LS800 & LS900); EC External Chambers, STW Stilling Wells and ST95 Seal Pots. 

3 YEAR WARRANTY FOR:

KCAP300 & KCAP400 capacitance switches. 

2 YEAR WARRANTY FOR:

AT100, AT100S and AT200 series transmitters; RS80 and RS85 liquid vibrating fork switches; RLT100 and RLT200 reed switch level  

transmitters;  TX, TS, TQ, IX and IM thermal dispersion switches; IR10 and PP10 External Relays; MT2000, MT5000, MT5100 and 

MT5200 radar level transmitters; RI100 Repeat Indicators; KP paddle switches; A02, A75 & A77 RF capacitance level switches and 

A38 RF capacitance level transmitters; Buoyancy Level Switches (MS50, MS10, MS8D & MS8F); Magnetic Level Switches (MS30, 

MS40, MS41, PS35 & PS45).

1 YEAR WARRANTY FOR:

KM50 gauging device; AT500 and AT600 series transmitters; LaserMeter and SureShot series laser transmitters; LPM200 digital 

indicator; DPM100 digital indicators; APM100 analog indicators; KVIEW series digital indicators and controllers; SF50 and SF60 

vibrating fork switches, KB Electro-Mechanical Continuous Measuring Devices, KSONIK ultrasonic level switches, transmitters & 

transducers, ChuteMaster Microwave Transmitter / Receiver and TiltMaster Switches.

SPECIAL WARRANTY CONSIDERATIONS:

ABB does not honor OEM warranties for items not manufactured by ABB (i.e. Palm Pilots).  These claims should be handled directly 

with the OEM.

ABB will repair or replace, at ABB’s election, defective items which are returned to ABB by the original purchaser within the period 

specified above from the shipment date of the item and which is found, upon examination by ABB, to its satisfaction, to contain de

-

fects in materials or workmanship which arose only under normal use and service and which were not the result of either alterations, 

misuse, abuse, improper or inadequate adjustments, applications or servicing of the product.  ABB’s warranty does not include 

onsite repair or services.  Field service rates can be supplied on request.

If a product is believed to be defective, the original purchaser shall notify ABB and request a Returned Material Authorization before 

returning the material to ABB, with transportation prepaid by the purchaser.  (To expedite all returns/repairs from outside of the 

United States, consult ABB’s customer service team ([email protected]) to determine an optimal solution for shipping method 

and turnaround time.)  The product, with repaired or replaced parts, shall be returned to the purchaser at any point in the world 

with transportation prepaid by ABB for best-way transportation only.  ABB is not responsible for expedited shipping charges.  If the 

product is shipped to ABB freight collect, then it will be returned to the customer freight collect.

If inspection by ABB does not disclose any defects in material or workmanship, ABB’s normal charges for repair and shipment shall 

apply (minimum 250.00 USD).

The materials of construction for all ABB products are clearly specified and it is the responsibility of the purchaser to determine the 

compatibility of the materials for the application.  

THE FOREGOING WARRANTY IS ABB’S SOLE WARRANTY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED, OR 

STATUTORY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, 

ARE EXCLUDED AND NEGATED TO THE MAXIMUM EXTENT PERMITTED BY LAW.  NO PERSON OR REPRESENTATIVE IS 

AUTHORIZED TO EXTEND ANY OTHER WARRANTY OR CREATE FOR ABB ANY OTHER LIABILITY IN CONNECTION WITH 

THE SALE OF ABB’S PRODUCTS.  THE REMEDIES SET FORTH IN THIS WARRANTY ARE EXCLUSIVE OF ALL OTHER REM-

EDIES AGAINST ABB.  ABB SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR SPECIAL DAMAGES OF 

ANY KIND.  ABB’S SOLE OBLIGATION SHALL BE TO REPAIR OR REPLACE PARTS (FOUND TO BE DEFECTIVE IN MATERI-

ALS OR WORKMANSHIP) WHICH ARE RETURNED BY THE PURCHASER TO ABB.

Содержание TS series

Страница 1: ...ev J Flow level granular solids and temperature switch K TEK Products Introduction This operating instruction manual provides the following information Calibration set point procedure see page 5 Configuration see page 7 Installation instructions see page 12 Troubleshooting see page 18 ...

Страница 2: ... Level Operation 13 5 3 Installation for Flow Rates Minimum and Maximum 13 5 4 Installation for Remote Electronics 14 5 5 Installation Setup 15 6 0 Flow Rate Detection 16 7 0 INTERFACE DETECTION 16 8 0 TEMPERATURE SWITCH OPTION 17 9 0 TROUBLESHOOTING 18 9 1 Voltage Resistance mesurments and Jumper Settings Main Board 18 9 2 Procedure for Measuring Voltage to the Sensor Using DVM with power applied...

Страница 3: ... against the probes the molecules of the medium absorb more heat from the active sensor and the voltage differential begins to drop or as the flow rate increases the voltage differential will decrease inverse relationship This is the basic principal behind thermal dispersion which allows the configuration of the instrument to trip on flow level or temperature to a set point or a combination of set...

Страница 4: ...rol system If fail safe is to be incorporated the output relay and green LED should be energized at what is determined as the normal condition JP3 jumpers are used to determine the relay action vs the normal process condition See the table on page 6 4 JP3 jumpers can be either in a vertical position State A or a horizontal position State B see page 6 Failsafe State required A or B Setting JP3 Jump...

Страница 5: ...lower values 3 1 Calibrate from HIGH TC Thermal Conductivity process conditions as follows JP3 State A Green LED output relay energized at NORMAL condition High Thermal Conductivity low differential temperature conditions at the sensors high level level above sensor flow above setpoint see table page 6 Notes 1 If the TX switch is operated in State A the TX switch should be adjusted calibrated in t...

Страница 6: ...Thermal Conductivity process condition high level level above sensor high flow condition at the sensor Green LED and output relay will be de energized after calibration adjust ments 2 Allow 5 minutes minimum time for switch temperature to stabilize 3 Adjust R18 see drawing page 5 as follows A If LED is On slowly turn R18 clockwise CW until the green LED turns OFF B If LED is Off slowly turn R18 co...

Страница 7: ...r a combination of level and temperature or flow and temperature with the dual switch point option With the dual switch point option board the flow rate of a process can be monitored with the millivolt output approximately 1 volt to 3 millivolts The millivolt output has an inverse relationship to flow In this configuration the unit is two switches contained in one housing The output of basic unit ...

Страница 8: ...Switch set for Level or Air Flow Fail Safe High Level or High Flow JP3 Relay set for State B Energizes when dry or below flow set point above setting of R18 Two Jumpers x 2mm Switch set for Temperature uses only the reference sensor STS or RTD JP3 Set for State A or B as shown To energize below or above setting of R18 State A Energize when temperature is below set point State B Energize when tempe...

Страница 9: ...ergized LED On Fail Safe WET or Air Flow Set Point Normal Condition DRY or Air Flow Set Point Normal Condition Relay De energized LED OFF DRY or Air Flow Set Point Normal Condition WET or Air Flow Set Point Normal Condition TEMPERATURE BOTTOM BOARD JP3 Jumper Configuration Condition State A State B Relay Energized LED On Fail Safe Temperature Set Point Normal Condition Temperature Set Point Normal...

Страница 10: ... the delta voltage The output has an inverse relationship to flow and is not linear the output voltage decreases as flow increases The amplified output does not apply when used as a temperature switch In addition the board also has 6 jumper terminals JP8 through JP13 that allow you to set up the electronics for Liquid Flow Air Flow Level Granular Solids Liquid and Temperature as follows Switch set...

Страница 11: ...ration Condition State A State B Relay Energized LED On DRY or Air Flow Set Point WET or Air Flow Set Point Relay De energized LED OFF WET or Air Flow Set Point DRY or Flow Set Point LEVEL OR AIR FLOW TOP BOARD JP11 Jumper Configuration Condition State A State B Relay Energized LED On Temperature Set Point Temperature Set Point Relay De energized LED OFF Temperature Set Point Temperature Set Point...

Страница 12: ...e leg used to mount the instrument be the same as the instrument connec tion size 1 MNPT type The standard instrument 1 8 inch will fit in a 1 X 1 X 1 or larger tee The 1 2 inch option units are available to insert directly into a 1 or tee For mounting flanged units the wrench flats on the sensor head should similarly be parallel to flow For liquid service fill the process line so that the probe i...

Страница 13: ... and Maximum This switch can be also be configured to detect between a minimum or a maximum flow rate or a minimum maximum temperature With the dual circuit board option the unit can also detect a flow rate and temperature in one housing The output relays would be wired in series PROCEDURE FOR LIQUID LEVEL OPERATION A The instrument detects the thermal conductivity of the medium surrounding the pr...

Страница 14: ...mperature that exceeds the maximum operating temperature 140 F or 65 C of the electronics module The remote housing simply contains a terminal block interface for a cable which connects to another housing containing the electronics that is located in a more suitable environment The cable can be one of two types each of which is designed for a specific temperature range See Ap pendix A ...

Страница 15: ...nit in a tee the tee size should be the same size as the line or smaller A larger diameter tee will allow the water to expand and cause false trip to occur because of vortices and or eddy currents The switch must be installed as show above in a flow application Rotating the switch from this position will cause the switch to respond slower and will alter a calibrated set point 5 5 Installation Setu...

Страница 16: ...onse time is needed the TQ version may be the solution For small flow rates the IX or IM in line unit would be the option The delta voltage will decrease With the dual switch point top board the delta voltage can be monitored and or plotted to determine flow rate inverse relationship and non linear The voltage output can not be used with temperature This switch can be configured to detect the inte...

Страница 17: ... 40 50 60 70 80 90 300 275 4 297 9 320 3 342 7 365 387 4 409 6 431 8 450 476 2 200 498 3 520 4 542 4 564 4 586 3 608 2 630 1 651 9 673 7 695 5 100 717 2 738 8 760 5 782 1 803 6 825 1 846 6 868 0 889 4 910 7 0 932 1 953 3 974 5 995 7 1016 9 1038 0 1059 1 1080 1 1101 1 1122 0 100 1142 9 1163 8 1184 6 1205 4 1226 2 1246 9 1267 5 1288 2 1308 8 1329 3 200 1349 8 1370 3 1390 7 1411 1 1431 4 1451 8 1472 ...

Страница 18: ...odel 141mV TQ Model 140mV TS Model 460mV IX Model 110mV Water TX HO Model 30mV H1 H2 Model 10mV TQ Model 25mV TS Model 90mV IX Model 15mV 9 2 1 With power disconnected measure resistance of Heater and Sensors P2 Sensor Plug disconnected Female Connector Pin 2 Black Wire Common to RTD Pins 4 5 172 ohms on the TX only Red Wires 470 ohms on the TS TQ IX and IM Red Wires Pins 1 2 1K ohm ambient temper...

Страница 19: ...Operating instruction manual TX Thermal Disperson Level Switches 19 10 0 APPENDIX A Instrument Rangeability 10 1 TX Series 10 2 IX Series ...

Страница 20: ...evel Switches Operating instruction manual 11 0 APPENDIX B Conversion Table Examples Example 1 100 CFM in 4 line 100 x 1884 18 84 F P S Example 2 10 G P M in 3 line 10 x 0434 434 F P S Test Conditions 60 F 14 7PSIA SCH 40 Line ...

Страница 21: ...ption H1 320 F 500 F RED RED WHT BLK GRN SEE WIRE MARKERS Special Temperature Range Option H2 100 F 900 F TERMINAL NUMBER 1 2 3 4 5 HTR HTR ACT COM REF Integral Electronics RED RED YEL BLK GRN Remote Electronics Type J Cable PVC BLUE WHITE DRAIN WHT BLK GRN Remote Electronics Type F Cable Teflon RED OF PAIR 1 RED FOIL BLACK OF PAIR 1 DRAIN OF PAIR 3 WHITE OF PAIR 2 GRN FOIL BLACKS OF PAIRS 2 3 GRE...

Страница 22: ...13 0 APPENDIX D TX Heating vs Dispersion Above is a graph of the model TX probe The longer line depicts the time response of the RTD by internal heating The shorter line depicts the delta voltage or delta temperature or delta resistance decreasing when immersed in water ...

Страница 23: ...ch were not the result of either alterations misuse abuse improper or inadequate adjustments applications or servicing of the product ABB s warranty does not include onsite repair or services Field service rates can be supplied on request If a product is believed to be defective the original purchaser shall notify ABB and request a Returned Material Authorization before returning the material to A...

Страница 24: ...evel Switches Operating instruction manual 15 0 CUSTOMER SUPPORT ABB USA Canada International 18321 Swamp Road Prairieville LA 70769 USA Tel 1 225 673 6100 Fax 1 225 673 2525 Email service ktekcorp com Website www abb com level ...

Страница 25: ...y Data Sheets MSDS and decontamination tags by affixing these documents in close proximity to the shipment label for identification purposes January 18 2006 Return Authorization Form Customer Date Contact Name Product Contact Email Serial No Contact Phone Job No Contact Fax Service Rep Completed by Customer Reason Problem Found None Action None Requested Is expedited return shipping requested If y...

Страница 26: ...26 TX Thermal Disperson Level Switches Operating instruction manual ...

Страница 27: ...Operating instruction manual TX Thermal Disperson Level Switches 27 ...

Страница 28: ...ible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB Copyright 2012 ABB All rights reserved ABB Inc 18321 Swamp Road Prairieville LA 70769 USA Phone 1 225 673 6100...

Отзывы: