Operation Manual / TPS48-D/E.. - TPS61-D/E..
5 Maintenance / 5.2 Cleaning the compressor during operation
© Copyright 2020 . All rights reserved.
HZTL2410_EN
Rev.F
March 2020
Procedure for wet cleaning the compressor with XC1
XSealing plug
DCompressed air
YValve activator
WWater
ZVessel
Operating the water pres-
sure vessel
u
Remove sealing plug (X).
u
Fill the vessel (Z) with clean water.
u
Screw in the sealing plug.
u
Push the valve activator (Y) against the spring and hold for 10 to 15
seconds until the entire volume of water has been injected.
u
Do not repeat the cleaning cycle until a stabilisation period of at least
10 minutes has elapsed.
NOTICE
Whether or not cleaning has been successful can be seen from the char-
ging or flushing pressure and also from the exhaust gas temperatures.
If the cleaning process is unsatisfactory, it can be repeated up to 2
times.
If the cleaning result is still not satisfactory after three attempts and
the engine values are also unsatisfactory, we recommend that you have
the turbocharger inspected and cleaned by an official ABB Turbochar-
ging Service Station.
Cleaning parameters per
turbocharger compressor
Product
Engine load
Contents
of cleaning me-
dium vessel
[dm
3
]
Water
injection time
t
1
[s]
TPS
50 … 85 %
0.4
10
Page
50
/
111
All manuals and user guides at all-guides.com