25
Figure 31 Carrier Gas Pressure Regulator with Relief Valve
B. Instructions
1)
Remove protective cap from High Pressure Inlet if required.
2)
Insert Ferrule on Regulator High Pressure Inlet into Carrier Gas Bottle Outlet.
3)
Screw Nut onto thread and tighten
4)
Check for leaks.
XIV.
CWE Calibration Gas Bottle Installation
The Calibration Gas Bottle mounting Rack is used to hold the Calibration Gas Bottle
when located inside of the Cold Weather Enclosure. A gas regulator should be installed
on each gas bottle. Refer to Figure 32.
A. Materials
•
Strapping material (shipped with Cold Weather Enclosure)
•
Calibration Gas Blend Bottle
B. Instructions
1)
Locate the bottle bracket in the right front area of the Cold Weather Enclosure
(see Figure 32).
2)
Set Calibration bottle inside of enclosure, situated against the Bottle Bracket.
3)
Thread strap through holes in bracket and around the bottle. Insert end of
strap into Worm Gear.
4)
Using a flat blade screw driver, turn screw on Worm Gear until strap is snug.