12.19.3
PE cable
Parameter
Specification
Cores
1 core, gn/ye
Cross section range
35 mm² (69 kcmil) (2 AWG)
Type
Flexible, unshielded
Diameter
13 - 21 mm
Length
Refer to the local rules.
Conductor
Fine strand copper wire according to
VDE 0295 Cl. 5/ IEC 60228 Cl. 5
Insulation
Special PVC that is serviceable for out-
door use, UV-protected, and oil resistant
Minimum nominal voltage Uo/U
600/1000 Vac
Minimum test voltage
4 kV
Ambient temperature range
-40°C to 80°C (-40 °F to +176 °F)
Diameter of the PE conductor
The same as the diameter of the phase
conductors
12.19.4
AC auxiliary power cables
Parameter
Specification
Number of cores
4
Cross section range
2.5 mm² (14 AWG)
Shielding
No
Conductor
Bare copper, fine wired, brunch stranded
according to VDE 0295 CI.5/IEC CI.5
Insulation
Special PVC ( that is serviceable for out-
door use, UV-protected, and oil resistant
Minimum nominal voltage (Uo/U)
450/750 Vac
Minimum test voltage (AC)
4 kV
Ambient temperature range
-40°C to +80°C (-40 °F to +176 °F)
Core identification
According to IEC 60446
Strip length
11 mm (0.43 in)
12.19.5
Interlock and DC guard cables
Parameter
Specification
Number of cores
2 x 2 twisted pair (4 core)
Diameter (inside)
1.3 to 2.1 mm² (16 to 14 AWG)
Diameter (outside)
10 to 17 mm (0.39 to 0.67 in)
Shielding
Tinned copper braid
Possible configuration: shielded 4 core
cable 2 x 2 pairs twisted or two separate
shielded dual core cables
Conductor
Fine strand copper wire
Technical data
92
9AKK107992A2254-EN | 005